A study of gamma attenuation parameters in poly methyl methacrylate and Kapton

被引:88
作者
Manjunatha, H. C. [1 ]
机构
[1] Govt Coll Women, Dept Phys, Kolar, Karnataka, India
关键词
PMMA; Mass attenuation coefficient; Effective atomic number; Electron density; Polymer; IONIZING-RADIATION; IRRADIATION;
D O I
10.1016/j.radphyschem.2016.01.024
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Poly methyl methacrylate (PMMA) and Kapton polyimide are polymers used for various aerospace applications. We have measured the gamma attenuation parameters such as mass attenuation coefficient, effective atomic number and electron density of PMMA and Kapton polyimide for various gamma sources of energy ranging from 84 keV to 1330 keV (Tm-170, Co-57, (141)Ice, Hg-203, Cr-51, Sn-113, Na-22, Cs-137, Co-60, Na-22 and Co-60). The measured values agree with the theoretical values. In the present work, we have also computed energy absorption build-up factors and exposure buildup factor of PMMA and Kapton polyimide for wide energy range (0.015-15 MeV) up to the penetration depth of 40 mean free path using Geometrical Progression fitting method. The values of these parameters have been found to change with energy and interaction of gamma with the medium. The present study on gamma attenuation parameters are expected to be helpful in dosimetry, radiation shielding and other radiation physics based applications. The experimental data on the mass attenuation coefficients for Kapton and PMMA is not available in literature. To my knowledge data available e.g. in the NIST data base are based on extrapolations from the measurement of mass attenuation coefficients for the elements. Hence this work is first of its kind and it is useful in the various field of Polymers. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:254 / 259
页数:6
相关论文
共 16 条
[1]  
American National Standard (ANS), 1991, GAMM RAY ATT COEF BU
[2]   Measurement of mass attenuation coefficients for four mixtures using X-rays from 13 keV up to 40 keV [J].
Angelone, M ;
Esposito, A ;
Chiti, M ;
Gentile, A .
RADIATION PHYSICS AND CHEMISTRY, 2001, 61 (3-6) :547-548
[3]   CLEAR PERSPEX HX AS A REFERENCE DOSEMETER FOR ELECTRON AND GAMMA RADIATION [J].
BERRY, RJ ;
MARSHALL, CH .
PHYSICS IN MEDICINE AND BIOLOGY, 1969, 14 (04) :585-&
[4]   Measurement of the x-ray mass attenuation coefficient of copper using 8.85-20 keV synchrotron radiation [J].
Chantler, CT ;
Tran, CQ ;
Barnea, Z ;
Paterson, D ;
Cookson, DJ ;
Balaic, DX .
PHYSICAL REVIEW A, 2001, 64 (06) :15
[5]   The effect of ionizing radiation on intraocular lenses [J].
Ellerin, BE ;
Nisce, LZ ;
Roberts, CW ;
Thornell, C ;
Sabbas, A ;
Wang, HL ;
Li, PM ;
Nori, D .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (01) :184-208
[6]   WinXCom - a program for calculating X-ray attenuation coefficients [J].
Gerward, L ;
Guilbert, N ;
Jensen, KB ;
Levring, H .
RADIATION PHYSICS AND CHEMISTRY, 2004, 71 (3-4) :653-654
[7]   Radiation effect of keV protons on optical properties of aluminized Kapton film [J].
Li, Ruiqi ;
Li, Chundong ;
He, Shiyu ;
Di, Mingwei ;
Yang, Dezhuang .
RADIATION PHYSICS AND CHEMISTRY, 2007, 76 (07) :1200-1204
[8]   Low temperature fast-neutron and gamma irradiation of Kapton(R) polyimide films [J].
Megusar, J .
JOURNAL OF NUCLEAR MATERIALS, 1997, 245 (2-3) :185-190
[9]  
Pawde S. M., 2009, J APPL POLYM SCI, V1, P2169
[10]  
Sidhu G. S., 2000, Journal of Radiological Protection, V20, P53, DOI 10.1088/0952-4746/20/1/306