Use of the Serratus Anterior Fascia Flap for Expander Coverage in Breast Reconstruction

被引:49
作者
Saint-Cyr, Michel [1 ]
Dauwe, Phillip [1 ]
Wong, Corrine [1 ]
Thakar, Hema [1 ]
Nagarkar, Purushottam [1 ]
Rohrich, Rod J. [1 ]
机构
[1] Univ Texas SW Med Ctr Dallas, Dept Plast Surg, Dallas, TX 75290 USA
关键词
SKIN-SPARING MASTECTOMY; VALVE TISSUE EXPANDERS; DORSAL HAND COVERAGE; IMPLANTS; MUSCLE; ALLODERM; PEDICLE; MATRIX;
D O I
10.1097/PRS.0b013e3181d17f61
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Postmastectomy partial submuscular tissue expander placement can prevent the upper pole fullness commonly seen with complete submuscular prosthesis placement. The resultant inferior and lateral margins require coverage to prevent prosthesis exposure. The fascial layer overlying the serratus anterior muscle can be used as an alternative to previously defined techniques to provide composite lateral coverage. This method offers adequate coverage, prevents expander lateralization, and minimizes use of allogenic material. This study reports the anatomy, surgical procedure, clinical outcomes, and aesthetics following use of the serratus anterior fascial flap for lateral expander coverage in postmastectomy expander-based breast reconstruction. Methods: Twenty-two patients (31 breasts) who underwent breast reconstruction with serratus fascia were included in a retrospective case-note analysis after approval by the institutional review board. Demographics, perioperative factors, postoperative complications, patient satisfaction, and aesthetics were recorded as relevant endpoints. Ten fresh cadaver hemichests were dissected, and the serratus fascia for each was measured for length and width. Results: At a mean follow-up of 197 days (range, 71 to 370 days), seroma occurred in two breasts, wound infection occurred in one breast, partial mastectomy skin flap necrosis occurred in four breasts, and minor wound dehiscence occurred in one breast. There were no incidences of capsular contracture or hematoma. Four patients (five breasts) reported very mild tightness or banding in the lateral chest wall. The mean length of cadaver serratus fascia was 164.3 mm and the mean width was 122.8 mm. Conclusion: The serratus anterior fascia flap is a versatile and safe alternative for providing vascularized composite lateral prosthesis coverage in expander-based breast reconstruction. (Plast. Reconstr. Surg. 125: 1057, 2010.)
引用
收藏
页码:1057 / 1064
页数:8
相关论文
共 27 条
[1]  
AKEISHI M, 2009, MICROSURG, V29, P95
[2]   Inferolateral AlloDerm hammock for implant coverage in breast reconstruction [J].
Breuing, Karl H. ;
Colwell, Amy S. .
ANNALS OF PLASTIC SURGERY, 2007, 59 (03) :250-255
[3]   Immediate bilateral breast reconstruction with implants and inferolateral AlloDerm slings [J].
Breuing, KH ;
Warren, SM .
ANNALS OF PLASTIC SURGERY, 2005, 55 (03) :232-239
[4]   Distal variations of the neurovascular pedicle of the serratus anterior muscle as a flap [J].
Erdogmus, S ;
Govsa, F .
SURGICAL AND RADIOLOGIC ANATOMY, 2005, 27 (02) :100-107
[5]   Serratus anterior free fascial flap for dorsal hand coverage [J].
Fassio, E ;
Laulan, J ;
Aboumoussa, J ;
Senyuva, C ;
Goga, D ;
Ballon, G .
ANNALS OF PLASTIC SURGERY, 1999, 43 (01) :77-82
[6]  
Fotopoulos P, 2003, J RECONSTR MICROSURG, V19, P555
[7]   Implant breast reconstruction using acellular dermal matrix [J].
Gamboa-Bobadilla, GM .
ANNALS OF PLASTIC SURGERY, 2006, 56 (01) :22-25
[8]   Subfascial breast implant: A new procedure [J].
Graf, RM ;
Bernardes, A ;
Rippel, R ;
Araujo, LRR ;
Damasio, RCC ;
Auersvald, A .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2003, 111 (02) :904-908
[9]   BREAST RECONSTRUCTION FOLLOWING MASTECTOMY - A COMPARISON OF SUB-MUSCULAR AND SUBCUTANEOUS TECHNIQUES [J].
GRUBER, RP ;
KAHN, RA ;
LASH, H ;
MASER, MR ;
APFELBERG, DB ;
LAUB, DR .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1981, 67 (03) :312-317
[10]   BREAST RECONSTRUCTION WITH AN EXTERNAL OBLIQUE ABDOMINIS MUSCLE TURNOVER FLAP AND A BIPEDICLED ABDOMINAL SKIN FLAP [J].
HOLLE, J ;
PIERINI, A .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1984, 73 (03) :469-473