Comparison of biodegradable and metallic tension-band fixation for patella fractures - 38 patients followed for 2 years

被引:30
作者
Chen, AM [1 ]
Hou, CL [1 ]
Bao, JL [1 ]
Guo, SH [1 ]
机构
[1] Second Mil Med Univ, Changzheng Hosp, Dept Orthoped, Shanghai 200003, Peoples R China
来源
ACTA ORTHOPAEDICA SCANDINAVICA | 1998年 / 69卷 / 01期
关键词
D O I
10.3109/17453679809002354
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We compared the outcome of patella fractures fixed by biodegradable tension-band (B) with self-reinforced polyglycolide or self-reinforced poly-L-lactide plugs and polyester ligaments or by metallic tension-band (M) with Kirschner wires and metallic cerclage wire in a randomized study. 38 fractures (18 with B and 20 with M) were treated. The follow-up time was 24 (14-32) months. The fractures healed in all patients after a medium of 8 weeks. In the B group, the clinical outcome was good in 13, fair in 4, and poor in 1 patient. In the M group, the corresponding figures were 15, 3 and 2. There were no clinical or radiographic differences between the two methods. Patella fractures can be treated, successfully using biodegradable tension-band fixation with no need for a second operation to remove the implants after bone union.
引用
收藏
页码:39 / 42
页数:4
相关论文
共 18 条
[1]   STRENGTH OF CARBON AND POLYESTER FIBER TENDON REPLACEMENTS - VARIATION AFTER OPERATION IN RABBITS [J].
AMIS, AA ;
CAMPBELL, JR ;
MILLER, JH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1985, 67 (05) :829-834
[2]   ANTERIOR CRUCIATE LIGAMENT REPLACEMENT - BIOCOMPATIBILITY AND BIOMECHANICS OF POLYESTER AND CARBON-FIBER IN RABBITS [J].
AMIS, AA ;
KEMPSON, SA ;
CAMPBELL, JR ;
MILLER, JH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (04) :628-634
[3]  
Becker D, 1991, Polim Med, V21, P25
[4]   FRACTURES OF THE PATELLA TREATED BY OPERATION [J].
BOSTMAN, O ;
KIVILUOTO, O ;
SANTAVIRTA, S ;
NIRHAMO, J ;
WILPPULA, E .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1983, 102 (02) :78-81
[5]   FOREIGN-BODY REACTIONS TO POLYGLYCOLIDE SCREWS - OBSERVATIONS IN 24/216 MALLEOLAR FRACTURE CASES [J].
BOSTMAN, O ;
PARTIO, E ;
HIRVENSALO, E ;
ROKKANEN, P .
ACTA ORTHOPAEDICA SCANDINAVICA, 1992, 63 (02) :173-176
[6]   ABSORBABLE IMPLANTS FOR THE FIXATION OF FRACTURES [J].
BOSTMAN, OM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (01) :148-153
[7]  
BRAY TJ, 1988, OPERATIVE ORTHOPEDIC, P413
[8]   INTERNAL-FIXATION FOR FRACTURES OF THE PATELLA - A COMPARISON OF 2 METHODS [J].
CURTIS, MJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (02) :280-282
[9]   RECONSTRUCTION OF THE EXTENSOR APPARATUS OF THE KNEE WITH THE LEEDS-KEIO LIGAMENT [J].
FUJIKAWA, K ;
OHTANI, T ;
MATSUMOTO, H ;
SEEDHOM, BB .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (02) :200-203
[10]  
LEVACK B, 1985, J BONE JOINT SURG BR, V67, P416, DOI 10.1302/0301-620X.67B3.3997951