Effect of Sterilization on Cyclic Fatigue Resistance of Proflexendo Endodontic Rotary Files

被引:4
|
作者
Alshwaimi, Emad O. [1 ]
机构
[1] Imam Abdulrahman Bin Faisal Univ, Coll Dent, Dept Restorat Dent Sci, POB 1982, Dammam 31441, Saudi Arabia
来源
关键词
Cyclic fatigue; endodontic rotary file; nickel-titanium; Proflexendo; sterilization; NICKEL-TITANIUM; MECHANICAL-PROPERTIES; TORSIONAL PROPERTIES; AUTOCLAVE STERILIZATION; CENTERING ABILITY; CONTROLLED MEMORY; ROTATIONAL SPEED; K-FILES; M-WIRE; INSTRUMENTS;
D O I
10.4103/sjmms.sjmms_123_17
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Proflexendo file (Nexen, Houston, TX, USA) is a recently developed, novel nickel-titanium rotary file. However, several physical properties of the Proflexendo system remain to be investigated. Objectives: The aim of this study was to determine the effect of sterilization on cyclic resistance of Proflexendo files. Material and Methods: A total of 120 unused Proflexendo rotary files (90 each of file sizes 90/0.04, 30/0.04 and 20/0.06) were used in this study. Each set of files was subdivided into four groups of ten files. Group 1 did not undergo any sterilization (control), Group 2 underwent two rounds (2x) of sterilization, Group 3 five rounds (5x) and Group 4 ten rounds (10x). Cyclic fatigue resistance was tested using an artificial canal with a 5-mm radius curve. Results: The nonsterilized size 30,9.04 files had the highest cycles to failure, followed by the nonsterilized size 40/0.04 and 20/0.06 files (P < 0.001). With increasing rounds of sterilization, cycles to failure reduced for sizes 40 (2x, 5x and 10x) and 30 (2x) files compared with nonsterilized sizes 40 (P < 0.05) and 30 files (P < 0.001), respectively. Conclusion: Under the conditions of the current study, the results provide preliminary evidence that autoclave sterilization of Proflexendo rotary files reduced their cyclic fatigue resistance, except for size 20 (2x and 5x) and 30 (10x) files, in which resistance increased. Single use of this file is recommended to reduce the risk of separation.
引用
收藏
页码:151 / 155
页数:5
相关论文
共 50 条
  • [11] Effect of sterilization on the cutting efficiency of rotary nickel-titanium endodontic files
    Rapisarda, E
    Bonaccorso, A
    Tripi, TR
    Condorelli, GG
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1999, 88 (03): : 343 - 347
  • [12] Can Measurement of Cyclic Fatigue Resistance for Titanium-Molybdenum Alloy as Rotary Endodontic Files (An In vitro Study)
    Sabah, Mohammad K.
    Hammed, Mohammed R.
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2022, 10 (05): : 116 - 123
  • [13] Resistance to Cyclic Fatigue Failure of a New Endodontic Rotary File
    Bouska, Jason
    Justman, Bruce
    Williamson, Anne
    DeLong, Christopher
    Qian, Fang
    JOURNAL OF ENDODONTICS, 2012, 38 (05) : 667 - 669
  • [14] Effect of simulated clinical use and sterilization on the cyclic fatigue resistance of nickel titanium files
    Alajemi, Mohammad
    AbuMostafa, Ammar
    PEERJ, 2024, 12
  • [15] THE EFFECT OF AUTOCLAVE STERILIZATION ON ENDODONTIC FILES
    MITCHELL, BF
    JAMES, GA
    NELSON, RC
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1983, 55 (02): : 204 - 207
  • [16] Comparing the impact of various sterilization methods on the cyclic fatigue resistance, bending strength, and torsional fatigue properties of NiTi rotary files
    Almnea, Raid Abdullah
    MATERIALS RESEARCH EXPRESS, 2024, 11 (07)
  • [17] Effect of Autoclaving Cycles on the Cyclic Fatigue Resistance of Race and Race Evo Nickel-Titanium Endodontic Rotary Files: An In Vitro Study
    Almohareb, Rahaf A.
    Barakat, Reem
    Albakri, Aroob
    Altamimi, Manal
    METALS, 2021, 11 (12)
  • [18] Shot peening increases resistance to cyclic fatigue fracture of endodontic files
    Nino-Barrera, Javier
    Sanchez-Aleman, Jose
    Acosta-Humanez, Manuel
    Gamboa-Martinez, Luis
    Cortes-Rodriguez, Carlos
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [19] Shot peening increases resistance to cyclic fatigue fracture of endodontic files
    Javier Nino-Barrera
    Jose Sanchez-Aleman
    Manuel Acosta-Humanez
    Luis Gamboa-Martinez
    Carlos Cortes-Rodriguez
    Scientific Reports, 11
  • [20] Effect of reciprocation usage of nickel-titanium rotary files on the cyclic fatigue resistance
    Lee, WooCheol
    Hwang, You-Jeong
    You, Sung-Yeop
    Kim, Hyeon-Cheol
    AUSTRALIAN ENDODONTIC JOURNAL, 2013, 39 (03) : 146 - 150