Dual-construct fixation is recommended in ipsilateral femoral neck fractures with infra-isthmus shaft fracture A STROBE compliant study

被引:8
作者
Wei, Yi Ping [1 ]
Lin, Kai Cheng [1 ]
机构
[1] Kaohsiung Vet Gen Hosp, Dept Orthoped, Kaohsiung, Taiwan
关键词
basicervical neck fracture; ipsilateral femoral neck and shaft fractures; malreduction; NAIL; HIP; FEMUR;
D O I
10.1097/MD.0000000000025708
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study was to evaluate the risk factors related to osteosynthesis failure in patients with concomitant ipsilateral femoral neck and shaft fractures, including old age; smoking habit; comminuted fragments; infra-isthmus fracture; angular malreduction; unsatisfactory reduction (fracture gap >5 mm); and treatment with single construct. Patients over the age of 20 with concomitant ipsilateral femoral neck and shaft fractures diagnosed at a level one medical center between 2003 and 2019 were included. Treatment modalities included single construct with/without an antirotational screw for the neck and dual constructs. Radiographic outcomes were assessed from anteroposterior and lateral hip radiographs at follow-up. Fisher exact test was used to analyze categorical variables. The presence of avascular necrosis of the femoral head, delayed union, atrophic or hypertrophic nonunion of the femoral shaft fracture, and loss of reduction were identified as factors related to treatment failure. A total of 22 patients were included in this study. The average age was 58.5 years, and the majority was male (68.2%). The minimum radiographic follow-up duration was 12 months, and the median follow-up time was 12 (interquartile range 12-24) months. Femoral neck osteosynthesis failed in 3 patients, whereas femoral shaft osteosynthesis failed in 12 patients. Fisher exact test demonstrated the failure of femoral shaft osteosynthesis was significantly more frequent in the single-construct cohort in 16 infra-isthmus femoral fracture cases (P = .034). In ipsilateral femoral neck and infra-isthmus shaft fractures, it is better to treat the neck and shaft fractures with separate implants (dual constructs). In a dual-construct cohort, separate plate fixation of the femoral shaft achieved a better result in terms of bone union than retrograde nailing of the shaft (bone union rate: 4/8 vs 0/2).
引用
收藏
页数:7
相关论文
共 18 条
  • [1] Surgical fixation of ipsilateral femoral neck and shaft fractures: a matter of debate?
    Bastian, Johannes D.
    Ivanova, Silviya
    Mabrouk, Ahmed
    Biberthaler, Peter
    Caba-Doussoux, Pedro
    Kanakaris, Nikolaos K.
    EFORT OPEN REVIEWS, 2023, 8 (09) : 698 - 707
  • [2] Ipsilateral Neck/Inter-Trochanteric and Mid-shaft Femoral Fractures Treated with Dual Construct Implants
    Chaudhary, Rahul
    Samal, Nitin
    Chaudhary, Sanjeev
    JOURNAL OF PHARMACEUTICAL RESEARCH INTERNATIONAL, 2021, 33 (58A) : 426 - 434
  • [3] Accuracy of Reduction of Ipsilateral Femoral Neck and Shaft Fractures - An Analysis of Various Internal Fixation Strategies
    Bedi, Asheesh
    Karunakar, Madhav A.
    Caron, Troy
    Sanders, Roy W.
    Haidukewych, George J.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2009, 23 (04) : 249 - 253
  • [4] The biomechanics of ipsilateral intertrochanteric and femoral shaft fractures: A comparison of 5 fracture fixation techniques
    McConnell, Alison
    Zdero, Rad
    Syed, Khalid
    Peskun, Christopher
    Schetnitsch, Emil
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (08) : 517 - 524
  • [5] Single versus separate implant fixation for concomitant ipsilateral femoral neck and shaft fractures: A systematic review
    Mohan, Kunal
    Ellanti, Prasad
    French, Helen
    Hogan, Niall
    McCarthy, Tom
    ORTHOPEDIC REVIEWS, 2019, 11 (02) : 85 - 92
  • [6] The surgical outcomes of fixing ipsilateral femoral neck and shaft fractures: single versus double implants fixation
    Alborno, Yahya
    Abunimer, Abdullah
    Abuodeh, Yousef
    Salameh, Motasem
    Kayali, Hammam
    Ahmed, Ghalib
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2023, 33 (05) : 1613 - 1618
  • [7] Unusual combination of femoral head dislocation associated acetabular fracture with ipsilateral neck and shaft fractures: A case report
    Duygulu, Fuat
    Calis, Mustafa
    Argun, Mahmut
    Guney, Ahmet
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2006, 61 (06): : 1545 - 1548
  • [8] Conversion hip arthroplasty for failed internal fixation of ipsilateral femoral neck and shaft fractures: a case report
    Mencia, Marlon M.
    Cruz, Pablo Pedro Hernandez
    PATIENT SAFETY IN SURGERY, 2023, 17 (01)
  • [9] The surgical outcomes of fixing ipsilateral femoral neck and shaft fractures: single versus double implants fixation
    Yahya Alborno
    Abdullah Abunimer
    Yousef Abuodeh
    Motasem Salameh
    Hammam Kayali
    Ghalib Ahmed
    European Journal of Orthopaedic Surgery & Traumatology, 2023, 33 : 1613 - 1618
  • [10] Protocolised MRI as an adjunct to CT in the diagnosis of femoral neck fracture in high energy ipsilateral femoral shaft fractures - A break-even analysis
    MacKinnon, Thomas
    Selmi, Hussain
    Davies, Andrew
    Packer, Timothy W.
    Reilly, Peter
    Sarraf, Khaled M.
    Sabharwal, Sanjeeve
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (12): : 4099 - 4103