Anatomic Study of Nutrient Foramina of Posterior Axis with Application to C2 Pedicle Screw Placement

被引:1
作者
Tawfik, Tamir [1 ]
Iwanaga, Joe [2 ,3 ]
Yilmaz, Emre [1 ]
Choi, Paul [2 ]
Wilson, Charlotte [2 ]
Simonds, Emily [2 ]
Marks, Jared J. [4 ]
Harkey, Haynes L. [4 ]
Oskouian, Rod J. [1 ]
Tubbs, R. Shane [2 ,5 ]
机构
[1] Swedish Med Ctr, Swedish Neurosci Inst, Seattle, WA USA
[2] Seattle Sci Fdn, Seattle, WA 98122 USA
[3] Kurume Univ, Sch Med, Dept Anat, Div Gross & Clin Anat, Kurume, Fukuoka, Japan
[4] Univ Mississippi, Med Ctr, Dept Neurosurg, Jackson, MS 39216 USA
[5] St Georges Univ, Dept Anat Sci, St Georges, Grenada
关键词
Anatomy; Axis; Cervical spine; Landmarks; Pedicle screw; VERTEBRAL ARTERY; CERVICAL-SPINE;
D O I
10.1016/j.wneu.2018.02.043
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: Pedicle screws placed into C2 necessitae a thorough understanding of this bone's unique anatomy. Although multiple landmarks and measurements have been used by surgeons, these are often varied in the literature with no consensus. Herein, we studied one recently proposed landmark using the nutrient foramina of the posterior aspect of C2 for pedicle screw placement. METHODS: On 19 (38 sides) C2 dry bone specimens, the presence, size, location, and distance from the midline of the nutrient foramina found at the junction between the isthmus and lamina were documented and measured. In addition, to discern the source of the artery entering such foramina, an injected adult cadaver was dissected. RESULTS: The number of foramina ranged from 0-5 with a mean of 1.84. On 3 sides, no foramina were identified. The mean diameter of the foramina was 0.57 mm. The location of the foramina was at position 1 on 9.5% of sides, position 2 on 66.4% of sides, and position 3 on 24.1% of sides. The mean horizontal distance from the midline of the spinous process of C2 to the foramina was 25.17 mm. In the cadaveric specimen, the source of the artery entering these C2 nutrient foramina was found to be distal branches of the deep cervical artery. CONCLUSIONS: We found the nutrient foramina of the C2 laminae are useful for pedicle screw placement. However, there are minor variations of the number and position of these structures. Lastly, on the basis of our study, 7.9% (n = 3) of sides will not have such foramina.
引用
收藏
页码:E408 / E413
页数:6
相关论文
共 50 条
  • [41] Determining C2 Pedicle Screw Placement Feasibility in the Pediatric Population: A Computed Tomographic Safe Zone Analysis
    Hirase, Takashi
    Wu Zhuge
    Phelps, Christopher, I
    Kushwaha, Vivek P.
    Marco, Rex A. W.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2021, 41 (09) : 580 - 584
  • [42] Feasibility of C2 Translaminar Screw as an Alternative or Salvage of C2 Pedicle Screws in Atlantoaxial Instability
    Park, Jae Suk
    Cho, Dae-Chul
    Sung, Joo Kyung
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2012, 25 (05): : 254 - 258
  • [43] Posterior fusion of the occipital axis in children with upper cervical disorder using both C2 pedicle and laminar screws (C2 hybrid screws)
    Ito, Kenyu
    Imagama, Shiro
    Ando, Kei
    Kobayashi, Kazuyoshi
    Tsushima, Mikito
    Matsumoto, Akiyuki
    Morozumi, Masayoshi
    Tanaka, Satoshi
    Machino, Masaaki
    Nishida, Yoshihiro
    Ishiguro, Naoki
    SPINE SURGERY AND RELATED RESEARCH, 2018, 2 (01):
  • [44] Anatomic suitability of the C1-C2 complex for pedicle screw fixation
    Resnick, DK
    Lapsiwala, S
    Trost, GR
    SPINE, 2002, 27 (14) : 1494 - 1498
  • [45] C2 Anatomy and Dimensions Relative to Translaminar Screw Placement in an Asian Population
    Ma, Xiang-Yang
    Yin, Qing-Shui
    Wu, Zeng-Hui
    Xia, Hong
    Riew, K. Daniel
    Liu, Jing-Fa
    SPINE, 2010, 35 (06) : 704 - 708
  • [46] Novel unilateral C1 double screw and ipsilateral C2 pedicle screw placement combined with contralateral laminar screw-rod fixation for atlantoaxial instability
    Shi, Lei
    Shen, Kai
    Deng, Rui
    Yan, Zheng-Jian
    Liang, Kai-Lu
    Chen, Liang
    Ke, Zhen-Yong
    Deng, Zhong-Liang
    EUROPEAN SPINE JOURNAL, 2019, 28 (02) : 362 - 369
  • [47] Computed Tomographic Morphometric Analysis of C1 and C2 for Lamina Cross Screw Placement in Malay Ethnicity
    Chan, Allan Kah Hay
    Yusof, Mohd Imran
    Abdullah, Mohd Shafie
    ASIAN SPINE JOURNAL, 2021, 15 (01) : 1 - 8
  • [48] Feasibility of C2 Pedicle Screw Fixation With the "in-out-in" Technique for Patients With Basilar Invagination
    Xu, Panjie
    Lin, Junyu
    Xiao, Hang
    Zheng, Jianying
    Ji, Wei
    SPINE, 2024, 49 (11) : 798 - 804
  • [49] Asymmetry of the C2 pars interarticularis: a clinical anatomical study with relevance to screw placement
    Brendan Huang
    Pervez A. Khan
    Joe Iwanaga
    Mi-Sun Hur
    R. Shane Tubbs
    Christopher M. Maulucci
    Surgical and Radiologic Anatomy, 2022, 44 : 423 - 429
  • [50] Clinical application of the C2 pars screw technique in the treatment of ossification of the posterior longitudinal ligament
    Wang, Zheng
    Chang, Heng-Rui
    Liu, Zhen
    Wang, Zhi-Wei
    Ding, Wen-Yuan
    Yang, Da-Long
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)