Anatomic Study of Nutrient Foramina of Posterior Axis with Application to C2 Pedicle Screw Placement

被引:1
|
作者
Tawfik, Tamir [1 ]
Iwanaga, Joe [2 ,3 ]
Yilmaz, Emre [1 ]
Choi, Paul [2 ]
Wilson, Charlotte [2 ]
Simonds, Emily [2 ]
Marks, Jared J. [4 ]
Harkey, Haynes L. [4 ]
Oskouian, Rod J. [1 ]
Tubbs, R. Shane [2 ,5 ]
机构
[1] Swedish Med Ctr, Swedish Neurosci Inst, Seattle, WA USA
[2] Seattle Sci Fdn, Seattle, WA 98122 USA
[3] Kurume Univ, Sch Med, Dept Anat, Div Gross & Clin Anat, Kurume, Fukuoka, Japan
[4] Univ Mississippi, Med Ctr, Dept Neurosurg, Jackson, MS 39216 USA
[5] St Georges Univ, Dept Anat Sci, St Georges, Grenada
关键词
Anatomy; Axis; Cervical spine; Landmarks; Pedicle screw; VERTEBRAL ARTERY; CERVICAL-SPINE;
D O I
10.1016/j.wneu.2018.02.043
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: Pedicle screws placed into C2 necessitae a thorough understanding of this bone's unique anatomy. Although multiple landmarks and measurements have been used by surgeons, these are often varied in the literature with no consensus. Herein, we studied one recently proposed landmark using the nutrient foramina of the posterior aspect of C2 for pedicle screw placement. METHODS: On 19 (38 sides) C2 dry bone specimens, the presence, size, location, and distance from the midline of the nutrient foramina found at the junction between the isthmus and lamina were documented and measured. In addition, to discern the source of the artery entering such foramina, an injected adult cadaver was dissected. RESULTS: The number of foramina ranged from 0-5 with a mean of 1.84. On 3 sides, no foramina were identified. The mean diameter of the foramina was 0.57 mm. The location of the foramina was at position 1 on 9.5% of sides, position 2 on 66.4% of sides, and position 3 on 24.1% of sides. The mean horizontal distance from the midline of the spinous process of C2 to the foramina was 25.17 mm. In the cadaveric specimen, the source of the artery entering these C2 nutrient foramina was found to be distal branches of the deep cervical artery. CONCLUSIONS: We found the nutrient foramina of the C2 laminae are useful for pedicle screw placement. However, there are minor variations of the number and position of these structures. Lastly, on the basis of our study, 7.9% (n = 3) of sides will not have such foramina.
引用
收藏
页码:E408 / E413
页数:6
相关论文
共 50 条
  • [21] Correlation between computed tomography measurements and direct anatomic measurements of the axis for consideration of C2 laminar screw placement
    Dean, Clayton L.
    Lee, Michael J.
    Robbin, Mark
    Cassinelli, Ezequiel H.
    SPINE JOURNAL, 2009, 9 (03) : 258 - 262
  • [22] Computed Tomography-Guided C2 Pedicle Screw Placement for Treatment of Unstable Hangman Fractures
    Singh, Pankaj Kumar
    Garg, Kanwaljeet
    Sawarkar, Duttaraj
    Agarwal, Deepak
    Satyarthee, Guru Dutta
    Gupta, Deepak
    Sinha, Sumit
    Kale, Shashank Sarad
    Sharma, Bhawani Shankar
    SPINE, 2014, 39 (18) : E1058 - E1065
  • [23] Asymmetry of the C2 pars interarticularis: a clinical anatomical study with relevance to screw placement
    Huang, Brendan
    Khan, Pervez A.
    Iwanaga, Joe
    Hur, Mi-Sun
    Tubbs, R. Shane
    Maulucci, Christopher M.
    SURGICAL AND RADIOLOGIC ANATOMY, 2022, 44 (03) : 423 - 429
  • [24] Anatomical Considerations for Subaxial (C2) Pedicle Screw Placement A Radiographic Study With Computed Tomography in 93 Patients
    Smith, Zachary A.
    Bistazzoni, Simona
    Onibokun, Adebukoa
    Chen, Nan-Fu
    Sassi, Marco
    Khoo, Larry T.
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2010, 23 (03): : 176 - 179
  • [25] Safety and Accuracy of Anatomic and Lateral Fluoroscopic-Guided Placement of C2 Pars/Pedicle Screws and C1 Lateral Mass Screws, and Freehand Placement of C2 Laminar Screws
    Kiran, Narayanam Anantha Sai
    Sivaraju, Laxminadh
    Vidyasagar, Kanneganti
    Aryan, Sarita
    Raj, Vivek
    Rajagopal, Niranjana
    Mohan, Dilip
    Thakar, Sumit
    Rao, Arun Sadashiva
    Hegde, Alangar S.
    WORLD NEUROSURGERY, 2018, 118 : E304 - E315
  • [26] Accuracy of Patient-Specific Template-Guided Versus Freehand Cervical Pedicle Screw Placement from C2 to C7: A Randomized Cadaveric Study
    Moser, Manuel
    Farshad, Mazda
    Farshad-Amacker, Nadja A.
    Betz, Michael
    Spirig, Jose Miguel
    WORLD NEUROSURGERY, 2019, 126 : E803 - E813
  • [27] A New Entrance Technique for C2 Pedicle Screw Placement and the Use in Patients With Atlantoaxial Instability
    Liu, Jia-Ming
    Jiang, Jian
    Liu, Zhi-Li
    Long, Xin-Hua
    Chen, Wen-Zhao
    Zhou, Yang
    Gao, Song
    He, Lai-Chang
    Huang, Shan-Hu
    CLINICAL SPINE SURGERY, 2017, 30 (05): : E573 - E577
  • [28] Morphology analysis of the C2 pediculoisthmic component and feasibility of safe C2 pedicle screw placement: comparison of multiplanar reconstruction versus traditional radiographic methods
    Wu, YueLin
    Liang, ZhaoQuan
    Bao, JunHao
    Wen, Ling
    Zhang, Li
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [29] Morphology analysis of the C2 pediculoisthmic component and feasibility of safe C2 pedicle screw placement: comparison of multiplanar reconstruction versus traditional radiographic methods
    YueLin Wu
    ZhaoQuan Liang
    JunHao Bao
    Ling Wen
    Li Zhang
    Journal of Orthopaedic Surgery and Research, 18
  • [30] Establishing Safe Surgical Parameters for Placement of C2 Pedicle Screws: A Retrospective Study
    Tunc, Bekir
    Divanlioglu, Denizhan
    Gunerhan, Goksal
    Isitan, Egemen
    Cagil, Emin
    Dalgic, Ali
    JOURNAL OF NEUROLOGICAL SURGERY PART A-CENTRAL EUROPEAN NEUROSURGERY, 2024,