Anatomic Study of Nutrient Foramina of Posterior Axis with Application to C2 Pedicle Screw Placement

被引:1
|
作者
Tawfik, Tamir [1 ]
Iwanaga, Joe [2 ,3 ]
Yilmaz, Emre [1 ]
Choi, Paul [2 ]
Wilson, Charlotte [2 ]
Simonds, Emily [2 ]
Marks, Jared J. [4 ]
Harkey, Haynes L. [4 ]
Oskouian, Rod J. [1 ]
Tubbs, R. Shane [2 ,5 ]
机构
[1] Swedish Med Ctr, Swedish Neurosci Inst, Seattle, WA USA
[2] Seattle Sci Fdn, Seattle, WA 98122 USA
[3] Kurume Univ, Sch Med, Dept Anat, Div Gross & Clin Anat, Kurume, Fukuoka, Japan
[4] Univ Mississippi, Med Ctr, Dept Neurosurg, Jackson, MS 39216 USA
[5] St Georges Univ, Dept Anat Sci, St Georges, Grenada
关键词
Anatomy; Axis; Cervical spine; Landmarks; Pedicle screw; VERTEBRAL ARTERY; CERVICAL-SPINE;
D O I
10.1016/j.wneu.2018.02.043
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: Pedicle screws placed into C2 necessitae a thorough understanding of this bone's unique anatomy. Although multiple landmarks and measurements have been used by surgeons, these are often varied in the literature with no consensus. Herein, we studied one recently proposed landmark using the nutrient foramina of the posterior aspect of C2 for pedicle screw placement. METHODS: On 19 (38 sides) C2 dry bone specimens, the presence, size, location, and distance from the midline of the nutrient foramina found at the junction between the isthmus and lamina were documented and measured. In addition, to discern the source of the artery entering such foramina, an injected adult cadaver was dissected. RESULTS: The number of foramina ranged from 0-5 with a mean of 1.84. On 3 sides, no foramina were identified. The mean diameter of the foramina was 0.57 mm. The location of the foramina was at position 1 on 9.5% of sides, position 2 on 66.4% of sides, and position 3 on 24.1% of sides. The mean horizontal distance from the midline of the spinous process of C2 to the foramina was 25.17 mm. In the cadaveric specimen, the source of the artery entering these C2 nutrient foramina was found to be distal branches of the deep cervical artery. CONCLUSIONS: We found the nutrient foramina of the C2 laminae are useful for pedicle screw placement. However, there are minor variations of the number and position of these structures. Lastly, on the basis of our study, 7.9% (n = 3) of sides will not have such foramina.
引用
收藏
页码:E408 / E413
页数:6
相关论文
共 50 条
  • [1] The Vertebral Artery Cave at C2: Anatomic Study with Application to C2 Pedicle Screw Placement
    Tubbs, R. Shane
    Granger, Andre
    Fisahn, Christian
    Loukas, Marios
    Moisi, Marc
    Iwanaga, Joe
    Paulson, David
    Jeyamohan, Shiveindra
    Chapman, Jens R.
    Oskouian, Rod J.
    WORLD NEUROSURGERY, 2016, 94 : 368 - 374
  • [2] Anatomical Study of the Posterior Ascending Artery: Application to C2 Pedicle Screw Placement
    Iwanaga, Joe
    Simonds, Emily
    Choi, Paul J.
    Oskouian, Rod J.
    Tubbs, R. Shane
    WORLD NEUROSURGERY, 2018, 112 : E662 - E665
  • [3] POSTERIOR INSTRUMENTATION FOR LAMINAR SCREW OF C2: A DIMENSIONAL ANATOMIC STUDY OF AXIS
    Sorrenti, Luiz
    Iamaguchi, Mauricio Masasi
    Sposeto, Rafael Barban
    de Araujo, Marcelo Poderoso
    Iutaka, Alexandre Sadao
    Pessoa de Barros Filho, Tarcisio Eloy
    da Rocha, Ivan Dias
    ACTA ORTOPEDICA BRASILEIRA, 2009, 17 (04): : 219 - 223
  • [4] Anatomic consideration of C2 pedicle screw placement
    Ebraheim, N
    Rollins, JR
    Xu, RM
    Jackson, WT
    SPINE, 1996, 21 (06) : 691 - 694
  • [5] Anterior pedicle screw fixation of C2: an anatomic analysis of axis morphology and simulated surgical fixation
    Wu, Zeng-Hui
    Zheng, Yi
    Yin, Qing-Shui
    Ma, Xiang-Yang
    Yin, Yi-Hong
    EUROPEAN SPINE JOURNAL, 2014, 23 (02) : 356 - 361
  • [6] Anterior pedicle screw fixation of C2: an anatomic analysis of axis morphology and simulated surgical fixation
    Zeng-Hui Wu
    Yi Zheng
    Qing-Shui Yin
    Xiang-Yang Ma
    Yi-Hong Yin
    European Spine Journal, 2014, 23 : 356 - 361
  • [7] Freehand C2 Pedicle Screw Placement: Surgical Anatomy and Operative Technique
    Clifton, William
    Vlasak, Alexander
    Damon, Aaron
    Dove, Conrad
    Pichelmann, Mark
    WORLD NEUROSURGERY, 2019, 132 : 113 - 113
  • [8] Freehand technique for C2 pedicle and pars screw placement: is it safe?
    Punyarat, Prachya
    Buchowski, Jacob M.
    Klawson, Benjamin T.
    Peters, Colleen
    Lertudomphonwanit, Thamrong
    Riew, K. Daniel
    SPINE JOURNAL, 2018, 18 (07) : 1197 - 1203
  • [9] Safety and accuracy of freehand versus navigated C2 pars or pedicle screw placement
    Hlubek, Randall J.
    Bohl, Michael A.
    Cole, Tyler S.
    Morgan, Clinton D.
    Xu, David S.
    Chang, Steve W.
    Turner, Jay D.
    Kakarla, U. Kumar
    SPINE JOURNAL, 2018, 18 (08) : 1374 - 1381
  • [10] Using the lamina nutrient foramen as the entry point for posterior cervical pedicle screw placement
    Yang, Xuan
    Luo, Qing
    Li, Zhi-Qiang
    Zhang, Ning
    Chen, Xuan-Yin
    Zhou, Yang
    Deng, Hui-Lin
    Jiang, Jian
    Liu, Jia-Ming
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2021, 207