Averaged assessment of the soil moisture by medium-frequency dielcometry

被引:3
作者
Egorov, Yu. V. [1 ]
Kirichenko, A. V. [1 ]
Bobkov, A. V. [1 ]
Galitskii, V. I.
机构
[1] Moscow MV Lomonosov State Univ, Fac Soil Sci, Moscow 119991, Russia
关键词
CAPACITANCE TECHNIQUE; WATER CONTENT; FIELD;
D O I
10.1134/S1064229310020080
中图分类号
S15 [土壤学];
学科分类号
0903 ; 090301 ;
摘要
A dielcometric method was proposed for the determination of the average soil water content with long isolated electrodes covering a significant area of an experimental plot or another object of study. It was shown that, to increase the area covered, the measuring current frequency should be decreased proportionally to the increasing electrode length. At a medium frequency (1 MHz), the ratio between the capacitive and resistive components of the soil electric conductivity and their effect on the results of the water content measurements were determined. The sensitivity of the method to the changes in the soil moisture, temperature, and the content of salts in the soil solution, as well as its stability in time, was determined using model samples. The effect of the electrode-insulation properties was revealed.
引用
收藏
页码:187 / 193
页数:7
相关论文
共 21 条
[1]  
BERLINER NA, 1973, MOISTURE MEASUREMENT, P58
[2]  
BOBROV PP, 2006, DIELECTRIC PERMITTIV
[3]   SOIL-MOISTURE MEASUREMENT BY AN IMPROVED CAPACITANCE TECHNIQUE .1. SENSOR DESIGN AND PERFORMANCE [J].
DEAN, TJ ;
BELL, JP ;
BATY, AJB .
JOURNAL OF HYDROLOGY, 1987, 93 (1-2) :67-78
[4]  
DMITRIEV E A, 1977, Pochvovedenie, P135
[5]  
EGOROV YV, 2004, GAVRISH, P23
[6]  
GVOZDEV IL, 1992, B IZOBRET, V13, P14
[7]  
KISELEV NF, 1973, VESTN MOSK GOS U BP, P67
[8]   Field and laboratory calibration and test of TDR and capacitance techniques for indirect measurement of soil water content [J].
Lane, PNJ ;
Mackenzie, DH .
AUSTRALIAN JOURNAL OF SOIL RESEARCH, 2001, 39 (06) :1371-1386
[9]  
NASONOV EA, 1989, B IZOBRET, V42, P26
[10]  
NOVOZHILOV SV, 1981, B IZOBRET, V45, P17