Electrospray ionization mass spectrometry ion suppression/enhancement caused by column bleed for three mixed-mode reversed-phase/anion-exchange high-performance liquid chromatography columns

被引:5
作者
Walter, Thomas H. [1 ]
Blaze, Melvin M. T. [1 ]
Boissel, Cheryl [1 ]
机构
[1] Waters Corp, 34 Maple St, Milford, MA 01757 USA
关键词
STATIONARY PHASES; SILICA; SUPPRESSION; HYDROLYSIS; STABILITY;
D O I
10.1002/rcm.9098
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Rationale: Mixed-mode reversed-phase/anion exchange liquid chromatography is useful for separations of mixtures containing anions (e.g. ionized acids). However, when using this form of liquid chromatography with mass spectrometry detection, the bleed of amine-containing hydrolysis products from the columns may cause ion suppression or enhancement. Methods: Using electrospray ionization tandem quadrupole mass spectrometry detection, we determined the ion suppression or enhancement caused by column bleed for three mixed-mode reversed-phase/weak anion-exchange columns containing stationary phases that differ in chemical structure. Two of the stationary phases are based on silica particles, while the third uses ethylene-bridged hybrid organic/inorganic particles, which have improved hydrolytic stability. Mixtures of acidic and basic analytes were combined with the chromatography flow postcolumn, both with and without a column, and their mass spectrometry ion signal responses (peak areas) were determined. The ratio of signal response with and without a column is the matrix factor. Positive ion electrospray measurements were carried out using 0.1% formic acid (pH similar to 2.7) as a mobile phase additive, and 10mM ammonium formate (pH similar to 6.4) was used for negative ion electrospray detection. Results: The matrix factors under both positive and negative ionization modes were closest to 1 (0.74-1.16) for the hybrid particle-based columns, showing minimal ion suppression or enhancement. In contrast, the silica-based columns gave matrix factors ranging from 0.04 to 1.86, indicating high levels of ion suppression or enhancement. These results may be explained by the differences in the structures of the stationary phases, which affect the relative amounts of hydrolysis products that elute from the columns. Conclusions: The low levels of mass spectrometry ion suppression or enhancement caused by column bleed from the hybrid particle-based columns should allow for accurate quantitative mass spectrometric detection combined with mixed-mode reversed-phase/weak anion-exchange chromatography.
引用
收藏
页数:10
相关论文
共 26 条
[11]   Stability of silica-based, endcapped columns with pH 7 and 11 mobile phases for reversed-phase high-performance liquid chromatography [J].
Kirkland, JJ ;
Henderson, JW ;
DeStefano, JJ ;
vanStraten, MA ;
Claessens, HA .
JOURNAL OF CHROMATOGRAPHY A, 1997, 762 (1-2) :97-112
[12]   Mixed-mode ion-exchangers and their comparative chromatographic characterization in reversed-phase and hydrophilic interaction chromatography elution modes [J].
Laemmerhofer, Michael ;
Richter, Martin ;
Wu, Junyan ;
Nogueira, Raquel ;
Bicker, Wolfgang ;
Lindner, Wolfgang .
JOURNAL OF SEPARATION SCIENCE, 2008, 31 (14) :2572-2588
[13]  
Liu XD, 2007, AM LAB, V39, P22
[14]   Multimodal liquid chromatography of small molecules [J].
Mansour, Fotouh R. ;
Danielson, Neil D. .
ANALYTICAL METHODS, 2013, 5 (19) :4955-4972
[15]   Monitoring temporal evolution of silicate species during hydrolysis and condensation of silicates using mass spectrometry [J].
Pelster, SA ;
Schrader, W ;
Schüth, F .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (13) :4310-4317
[16]   Column bleed in the analysis of highly polar substances: an overlooked aspect in HRMS [J].
Schulze, Bastian ;
Bader, Tobias ;
Seitz, Wolfram ;
Winzenbacher, Rudi .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2020, 412 (20) :4837-4847
[17]   SOLID-STATE NMR-STUDIES OF THE REACTIONS OF SILICA SURFACES WITH POLYFUNCTIONAL CHLOROMETHYLSILANES AND ETHOXYMETHYLSILANES [J].
SINDORF, DW ;
MACIEL, GE .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1983, 105 (12) :3767-3776
[18]   CROSS-POLARIZATION MAGIC-ANGLE-SPINNING SI-29 NUCLEAR MAGNETIC-RESONANCE STUDY OF SILICA-GEL USING TRIMETHYLSILANE BONDING AS A PROBE OF SURFACE GEOMETRY AND REACTIVITY [J].
SINDORF, DW ;
MACIEL, GE .
JOURNAL OF PHYSICAL CHEMISTRY, 1982, 86 (26) :5208-5219
[19]   Recent advances in mixed-mode chromatographic stationary phases [J].
Sykora, David ;
Rezanka, Pavel ;
Zaruba, Kamil ;
Kral, Vladimir .
JOURNAL OF SEPARATION SCIENCE, 2019, 42 (01) :89-129
[20]   Characterization of a highly stable mixed-mode reversed-phase/weak anion-exchange stationary phase based on hybrid organic/inorganic particles [J].
Walter, Thomas H. ;
Alden, Bonnie A. ;
Field, Jessica A. ;
Lawrence, Nicole L. ;
Osterman, Donna L. ;
Patel, Amit, V ;
DeLoffi, Maureen A. .
JOURNAL OF SEPARATION SCIENCE, 2021, 44 (05) :1005-1014