Electrospray ionization mass spectrometry ion suppression/enhancement caused by column bleed for three mixed-mode reversed-phase/anion-exchange high-performance liquid chromatography columns

被引:5
作者
Walter, Thomas H. [1 ]
Blaze, Melvin M. T. [1 ]
Boissel, Cheryl [1 ]
机构
[1] Waters Corp, 34 Maple St, Milford, MA 01757 USA
关键词
STATIONARY PHASES; SILICA; SUPPRESSION; HYDROLYSIS; STABILITY;
D O I
10.1002/rcm.9098
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Rationale: Mixed-mode reversed-phase/anion exchange liquid chromatography is useful for separations of mixtures containing anions (e.g. ionized acids). However, when using this form of liquid chromatography with mass spectrometry detection, the bleed of amine-containing hydrolysis products from the columns may cause ion suppression or enhancement. Methods: Using electrospray ionization tandem quadrupole mass spectrometry detection, we determined the ion suppression or enhancement caused by column bleed for three mixed-mode reversed-phase/weak anion-exchange columns containing stationary phases that differ in chemical structure. Two of the stationary phases are based on silica particles, while the third uses ethylene-bridged hybrid organic/inorganic particles, which have improved hydrolytic stability. Mixtures of acidic and basic analytes were combined with the chromatography flow postcolumn, both with and without a column, and their mass spectrometry ion signal responses (peak areas) were determined. The ratio of signal response with and without a column is the matrix factor. Positive ion electrospray measurements were carried out using 0.1% formic acid (pH similar to 2.7) as a mobile phase additive, and 10mM ammonium formate (pH similar to 6.4) was used for negative ion electrospray detection. Results: The matrix factors under both positive and negative ionization modes were closest to 1 (0.74-1.16) for the hybrid particle-based columns, showing minimal ion suppression or enhancement. In contrast, the silica-based columns gave matrix factors ranging from 0.04 to 1.86, indicating high levels of ion suppression or enhancement. These results may be explained by the differences in the structures of the stationary phases, which affect the relative amounts of hydrolysis products that elute from the columns. Conclusions: The low levels of mass spectrometry ion suppression or enhancement caused by column bleed from the hybrid particle-based columns should allow for accurate quantitative mass spectrometric detection combined with mixed-mode reversed-phase/weak anion-exchange chromatography.
引用
收藏
页数:10
相关论文
共 26 条
[1]   The ion suppression phenomenon in liquid chromatography-mass spectrometry and its consequences in the field of residue [J].
Antignac, JP ;
de Wasch, K ;
Monteau, F ;
De Brabander, H ;
Andre, F ;
Le Bizec, B .
ANALYTICA CHIMICA ACTA, 2005, 529 (1-2) :129-136
[2]   Stable-bond polymeric reversed-phase/weak anion-exchange mixed-mode stationary phases obtained by simultaneous functionalization and crosslinking of a poly(3-mercaptopropyl)methylsiloxane-film on vinyl silica via thiol-ene double click reaction [J].
Baeurer, Stefanie ;
Zimmermann, Aleksandra ;
Woiwode, Ulrich ;
Sanchez-Munoz, Orlando L. ;
Kramer, Markus ;
Horak, Jeannie ;
Lindner, Wolfgang ;
Bicker, Wolfgang ;
Laemmerhofer, Michael .
JOURNAL OF CHROMATOGRAPHY A, 2019, 1593 :110-118
[3]   PREPARATION AND CHROMATOGRAPHIC PROPERTIES OF SOME CHEMICALLY BONDED PHASES FOR REVERSED-PHASE LIQUID-CHROMATOGRAPHY [J].
BERENDSEN, GE ;
GALAN, LD .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1978, 1 (05) :561-586
[4]   Review on the chemical and thermal stability of stationary phases for reversed-phase liquid chromatography [J].
Claessens, HA ;
van Straten, MA .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1060 (1-2) :23-41
[5]   ANALYSIS OF THE ACID-HYDROLYSIS PRODUCTS OF MONOFUNCTIONAL CHEMICALLY BONDED STATIONARY PHASES FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING CAPILLARY GAS-CHROMATOGRAPHY [J].
CROWTHER, JB ;
FAZIO, SD ;
SCHIKSNIS, R ;
MARCUS, S ;
HARTWICK, RA .
JOURNAL OF CHROMATOGRAPHY, 1984, 289 (APR) :367-375
[6]   EVALUATION OF MIXED-MODE STATIONARY PHASES IN LIQUID-CHROMATOGRAPHY FOR THE SEPARATION OF CHARGED AND UNCHARGED OLIGOMER-LIKE MODEL COMPOUNDS [J].
ELEVELD, JT ;
CLAESSENS, HA ;
AMMERDORFFER, JL ;
VANHERK, AM ;
CRAMERS, CA .
JOURNAL OF CHROMATOGRAPHY A, 1994, 677 (02) :211-227
[7]   Ion suppression; A critical review on causes, evaluation, prevention and applications [J].
Furey, Ambrose ;
Moriarty, Merisa ;
Bane, Vaishali ;
Kinsella, Brian ;
Lehane, Mary .
TALANTA, 2013, 115 :104-122
[8]   Signal suppression/enhancement in high-performance liquid chromatography tandem mass spectrometry [J].
Gosetti, Fabio ;
Mazzucco, Eleonora ;
Zampieri, Davide ;
Gennaro, Maria Carla .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (25) :3929-3937
[9]   Method for evaluation of ionic interactions in liquid chromatography [J].
Kadlecova, Zuzana ;
Kalikova, Kveta ;
Folprechtova, Denisa ;
Tesarova, Eva ;
Gilar, Martin .
JOURNAL OF CHROMATOGRAPHY A, 2020, 1625
[10]   HIGH PH MOBILE-PHASE EFFECTS ON SILICA-BASED REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC COLUMNS [J].
KIRKLAND, JJ ;
VANSTRATEN, MA ;
CLAESSENS, HA .
JOURNAL OF CHROMATOGRAPHY A, 1995, 691 (1-2) :3-19