A study of synthetic-aperture imaging with virtual source elements in B-mode ultrasound imaging systems

被引:151
|
作者
Bae, MH [1 ]
Jeong, MK
机构
[1] Medison Co, Ultrason Grp, Seoul, South Korea
[2] Univ Minnesota, Dept Elect & Comp Engn, Minneapolis, MN 55455 USA
关键词
D O I
10.1109/58.883540
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
We propose an all point transmit and receive focusing method based on transmit synthetic focusing combined with receive dynamic focusing in a linear array transducer, In the method, on transmit, a virtual source element is assumed to be located at the transmit focal depth of conventional B-mode imaging systems, and transmit synthetic focusing is used in two half planes, one before and the other after the transmit focal depth, using the rf data of each scanline, together with all other relevant rf scanline data previously stored. The proposed new method uses the same data acquisition scheme as the conventional focusing method while maintaining the same frame rate via high-speed signal processing, but it is not suitable for imaging moving objects. It improves upon the lateral resolution and sidelobe level at all imaging depths. Also, it increases the transmit power and image signal-to-noise ratio (SNR), due to transmit field synthesis, and extends the image penetration depth as well. Evaluations with simulation and experimental data show much improvement in resolution and SNR at all imaging depths.
引用
收藏
页码:1510 / 1519
页数:10
相关论文
共 50 条
  • [1] COMPARISON OF LINEAR-ARRAY B-MODE SCANNING AND COMPUTED SYNTHETIC-APERTURE ULTRASONOGRAPHIC IMAGING
    YLITALO, J
    JOURNAL OF ULTRASOUND IN MEDICINE, 1995, 14 (01) : 15 - 20
  • [2] ULTRASOUND SYNTHETIC-APERTURE IMAGING - MONOSTATIC APPROACH
    YLITALO, JT
    ERMERT, H
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1994, 41 (03) : 333 - 339
  • [3] High frame rate and high resolution ultrasound imaging with virtual source element in B-mode ultrasound system based on sparse synthetic transmit aperture method
    Kim, KS
    Song, TK
    MEDICAL IMAGING 2004: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2004, 5373 : 290 - 299
  • [4] SYNTHETIC-APERTURE RADAR IMAGING-SYSTEMS
    BIRK, R
    CAMUS, W
    VALENTI, E
    MCCANDLESS, W
    IEEE AEROSPACE AND ELECTRONIC SYSTEMS MAGAZINE, 1995, 10 (11) : 15 - 23
  • [5] SYNTHETIC-APERTURE RADAR IMAGING
    OLIVER, CJ
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1989, 22 (07) : 871 - 890
  • [6] Velocity vector estimation in synthetic aperture flow and B-MODE imaging
    Jensen, JA
    2004 2ND IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1 AND 2, 2004, : 33 - 36
  • [7] SYNTHETIC-APERTURE IMAGING FOR SMALL-SCALE SYSTEMS
    KARAMAN, M
    LI, PC
    ODONNELL, M
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1995, 42 (03) : 429 - 442
  • [8] Synthetic aperture imaging with a virtual source element
    Frazier, CH
    OBrien, WD
    1996 IEEE ULTRASONICS SYMPOSIUM, PROCEEDINGS, VOLS 1 AND 2, 1996, : 1555 - 1558
  • [9] Ultrasonic Synthetic-Aperture Interface Imaging
    van der Neut, Joost
    Fokkema, Jacob T.
    van den Berg, Peter M.
    Zapf, Michael
    Ruiter, Nicole V.
    Taskin, Ulas
    van Dongen, Koen W. A.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2019, 66 (05) : 888 - 897
  • [10] Synthetic-aperture chirp confocal imaging
    Chien, WC
    Dilworth, DS
    Liu, E
    Leith, EN
    APPLIED OPTICS, 2006, 45 (03) : 501 - 510