Catastrophic failure of the acetabular component in a ceramic-polyethylene bearing total hip arthroplasty

被引:35
作者
Simon, JA [1 ]
Dayan, AJ [1 ]
Ergas, E [1 ]
Stuchin, SA [1 ]
Di Cesare, PE [1 ]
机构
[1] Hosp Joint Dis & Med Ctr, Inst Orthopaed, New York, NY 10003 USA
关键词
ceramic femoral heads; polyethylene failure; uncemented acetabular component; catastrophic wear; hip arthroplasty;
D O I
10.1016/S0883-5403(98)90085-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Recent research in total hip arthroplasty has focused on attempts to decease wear at the femoral head-acetabulum articulation, to limit the production of debris that is believed to lead to osteolysis and prosthetic loosening. The use of ceramic-on-polyethylene bearing surfaces has been reported to produce lower wear rates and therefore may increase the Life expectancy of the joint arthroplasty. Problems with this bearing have been reported to be due to ceramic femoral head fracture. Reported here are 2 cases of catastrophic failure of total hip arthroplasties, involving a ceramic femoral head, caused by failure of the polyethylene acetabular liner, with subsequent penetration of the femoral head through the acetabular shell.
引用
收藏
页码:108 / 113
页数:6
相关论文
共 50 条
[41]   Long-term follow-up of total hip arthroplasty using polyethylene-ceramic composite (sandwich) liner [J].
Rodriguez-Perez, Daniel ;
Carnaval, Thiago ;
Rodriguez, Marcos-del-Carmen ;
Coscujuela-Mana, Antonio ;
Agullo, Jose-Luis ;
Videla, Sebastian .
HIP INTERNATIONAL, 2024, 34 (04) :467-475
[42]   Ceramic-on-ceramic total hip arthroplasty: Is squeaking related to an inaccurate three-dimensional hip anatomy reconstruction? [J].
Sariali, E. ;
Klouche, S. ;
Mamoudy, P. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2014, 100 (04) :437-440
[43]   FIRST CASE REPORT OF VANADIUM METALLOSIS AFTER CERAMIC-ON-CERAMIC TOTAL HIP ARTHROPLASTY [J].
Pesce, V. ;
Maccagnano, G. ;
Vicenti, G. ;
Notarnicola, A. ;
Lovreglio, P. ;
Soleo, L. ;
Pantalone, A. ;
Salini, V. ;
Moretti, B. .
JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2013, 27 (04) :1063-1068
[44]   Late Onset Atraumatic Ceramic Head Fracture of a Hybrid Ceramic Bearings Total Hip Arthroplasty [J].
Papaioannou, Ioannis ;
Repantis, Thomas ;
Pantazidou, Georgia ;
Baikousis, Andreas ;
Korovessis, Panagiotis .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (03)
[45]   The effect of BMI and surgical approach on acetabular component malpositioning in a cohort of military patients with hip arthroplasty [J].
Formby, Peter M. ;
Nappo, Kyle E. ;
Purcell, Richard L. ;
Pickett, Adam ;
Newman, Michael T. ;
Mack, Andrew W. .
CURRENT ORTHOPAEDIC PRACTICE, 2018, 29 (03) :244-249
[46]   Influence of surgical approach on component positioning in primary total hip arthroplasty [J].
Innmann, Moritz M. ;
Streit, Marcus R. ;
Kolb, Jeanette ;
Heiland, Jochen ;
Parsch, Dominik ;
Aldinger, Peter R. ;
Koenigshausen, Matthias ;
Gotterbarm, Tobias ;
Merle, Christian .
BMC MUSCULOSKELETAL DISORDERS, 2015, 16
[47]   Influence of surgical approach on component positioning in primary total hip arthroplasty [J].
Moritz M. Innmann ;
Marcus R. Streit ;
Jeanette Kolb ;
Jochen Heiland ;
Dominik Parsch ;
Peter R. Aldinger ;
Matthias Königshausen ;
Tobias Gotterbarm ;
Christian Merle .
BMC Musculoskeletal Disorders, 16
[48]   Pelvic mass caused by polyethylene wear after uncemented total hip arthroplasty [J].
Wang, JW ;
Lin, CC .
JOURNAL OF ARTHROPLASTY, 1996, 11 (05) :626-628
[49]   Assessment of Acetabular Component Anteversion after Total Hip Arthroplasty: Comparison of Anteroposterior and Cross-Table Lateral Radiographs with Computed Tomography Scans [J].
Goyal, Tarun ;
Paul, Souvik ;
Choudhury, Arghya Kundu ;
Gupta, Tushar .
CLINICS IN ORTHOPEDIC SURGERY, 2021, 13 (03) :329-335
[50]   Total hip arthroplasty following acetabular fracture: a clinical and radiographic outcome analysis of 67 patients [J].
André Busch ;
Ulrich Stöckle ;
Anna Schreiner ;
Peter de Zwaart ;
Aljoscha Schäffler ;
Björn Gunnar Ochs .
Archives of Orthopaedic and Trauma Surgery, 2020, 140 :331-341