Catastrophic failure of the acetabular component in a ceramic-polyethylene bearing total hip arthroplasty

被引:35
作者
Simon, JA [1 ]
Dayan, AJ [1 ]
Ergas, E [1 ]
Stuchin, SA [1 ]
Di Cesare, PE [1 ]
机构
[1] Hosp Joint Dis & Med Ctr, Inst Orthopaed, New York, NY 10003 USA
关键词
ceramic femoral heads; polyethylene failure; uncemented acetabular component; catastrophic wear; hip arthroplasty;
D O I
10.1016/S0883-5403(98)90085-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Recent research in total hip arthroplasty has focused on attempts to decease wear at the femoral head-acetabulum articulation, to limit the production of debris that is believed to lead to osteolysis and prosthetic loosening. The use of ceramic-on-polyethylene bearing surfaces has been reported to produce lower wear rates and therefore may increase the Life expectancy of the joint arthroplasty. Problems with this bearing have been reported to be due to ceramic femoral head fracture. Reported here are 2 cases of catastrophic failure of total hip arthroplasties, involving a ceramic femoral head, caused by failure of the polyethylene acetabular liner, with subsequent penetration of the femoral head through the acetabular shell.
引用
收藏
页码:108 / 113
页数:6
相关论文
共 50 条
[21]   Acetabular and Femoral Component Positioning Using Direct Anterior Approach Versus Posterior Approach in Total Hip Arthroplasty [J].
Goyal, Tarun ;
Choudhury, Arghya Kundu ;
Paul, Souvik ;
Gupta, Tushar ;
Das, Lakshmana .
INDIAN JOURNAL OF ORTHOPAEDICS, 2021, 55 (05) :1215-1224
[22]   Retrieval of ceramic wear couples in total hip arthroplasty [J].
Willmann, G ;
Schikora, N ;
Pitto, RP .
BIOCERAMICS 15, 2003, 240-2 :813-815
[23]   Use of cemented all-polyethylene and metal-backed acetabular components in total hip arthroplasty - A comparative study [J].
Markel, DC ;
Huo, MH ;
Katkin, PD ;
Salvati, EA .
JOURNAL OF ARTHROPLASTY, 1995, 10 :S1-S7
[24]   Effects of acetabular abduction on cup wear rates in total hip arthroplasty [J].
Del Schutte, H ;
Lipman, AJ ;
Bannar, SM ;
Livermore, JT ;
Ilstrup, D ;
Morrey, BF .
JOURNAL OF ARTHROPLASTY, 1998, 13 (06) :621-626
[25]   Total hip arthroplasty to treat acetabular protrusions secondary to rheumatoid arthritis [J].
Ping Zhen ;
Xusheng Li ;
Shenghu Zhou ;
Hao Lu ;
Hui Chen ;
Jun Liu .
Journal of Orthopaedic Surgery and Research, 13
[26]   Total hip arthroplasty to treat acetabular protrusions secondary to rheumatoid arthritis [J].
Zhen, Ping ;
Li, Xusheng ;
Zhou, Shenghu ;
Lu, Hao ;
Chen, Hui ;
Liu, Jun .
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2018, 13
[27]   Fracture of a ceramic femoral head after ceramic-on-ceramic total hip arthroplasty [J].
Malillos Toran, Manuel ;
Cuenca, Jorge ;
Antonio Martinez, Angel ;
Herrera, Antonio ;
Vicente Thomas, Javier .
JOURNAL OF ARTHROPLASTY, 2006, 21 (07) :1072-1073
[28]   Total hip arthroplasty using a Kerboull-type plate for rapidly destructive coxarthrosis: comparison with uncemented acetabular component [J].
Baba T. ;
Homma Y. ;
Ochi H. ;
Ozaki Y. ;
Matsumoto M. ;
Shitoto K. ;
Kaneko K. .
European Journal of Orthopaedic Surgery & Traumatology, 2016, 26 (2) :189-194
[29]   Use of a monoblock dual-mobility acetabular component in primary total hip arthroplasty in patients at high risk of dislocation [J].
Yang, JaeWon ;
Bryan, Andrew J. ;
Drabchuk, Roman ;
Tetreault, Matthew W. ;
Calkins, Tyler E. ;
Della Valle, Craig J. .
HIP INTERNATIONAL, 2022, 32 (05) :648-655
[30]   Accuracy of acetabular component alignment with surgical guidance systems during hip arthroplasty [J].
Xu, Joshua ;
Veltman, Ewout S. ;
Chai, Yuan ;
Walter, William L. .
SICOT-J, 2023, 9