Catastrophic failure of the acetabular component in a ceramic-polyethylene bearing total hip arthroplasty

被引:35
|
作者
Simon, JA [1 ]
Dayan, AJ [1 ]
Ergas, E [1 ]
Stuchin, SA [1 ]
Di Cesare, PE [1 ]
机构
[1] Hosp Joint Dis & Med Ctr, Inst Orthopaed, New York, NY 10003 USA
关键词
ceramic femoral heads; polyethylene failure; uncemented acetabular component; catastrophic wear; hip arthroplasty;
D O I
10.1016/S0883-5403(98)90085-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Recent research in total hip arthroplasty has focused on attempts to decease wear at the femoral head-acetabulum articulation, to limit the production of debris that is believed to lead to osteolysis and prosthetic loosening. The use of ceramic-on-polyethylene bearing surfaces has been reported to produce lower wear rates and therefore may increase the Life expectancy of the joint arthroplasty. Problems with this bearing have been reported to be due to ceramic femoral head fracture. Reported here are 2 cases of catastrophic failure of total hip arthroplasties, involving a ceramic femoral head, caused by failure of the polyethylene acetabular liner, with subsequent penetration of the femoral head through the acetabular shell.
引用
收藏
页码:108 / 113
页数:6
相关论文
共 50 条
  • [1] Spontaneous fracture of the ceramic ball in a ceramic-polyethylene total hip arthroplasty
    Michaud, RJ
    Rashad, SY
    JOURNAL OF ARTHROPLASTY, 1995, 10 (06) : 863 - 867
  • [2] Catastrophic failure of a modular revision total hip polyethylene insert
    Stiehl, James Bowen
    Mahfouz, Mohammed R.
    JOURNAL OF ARTHROPLASTY, 2007, 22 (01) : 143 - 147
  • [3] Body mass index and acetabular component position in total hip arthroplasty
    McBride, Andrew
    Flynn, Jennifer
    Miller, George
    Barnes, Matthew
    Mackie, Scott
    ANZ JOURNAL OF SURGERY, 2013, 83 (03) : 171 - 174
  • [4] Fracture of the femoral head after ceramic-on-polyethylene total hip arthroplasty
    Callaway, GH
    Flynn, W
    Ranawat, CS
    Sculco, TP
    JOURNAL OF ARTHROPLASTY, 1995, 10 (06) : 855 - 859
  • [5] Revision arthroplasty of the hip - Acetabular component
    Gollwitzer, H.
    von Eisenhart-Rothe, R.
    Holzapfel, B. M.
    Gradinger, R.
    CHIRURG, 2010, 81 (04): : 284 - +
  • [6] Augmented Reality for Acetabular Component Placement in Direct Anterior Total Hip Arthroplasty
    Alexander, Clayton
    Loeb, Alexander E.
    Fotouhi, Javad
    Navab, Nassir
    Armand, Mehran
    Khanuja, Harpal S.
    JOURNAL OF ARTHROPLASTY, 2020, 35 (06) : 1636 - +
  • [7] Catastrophic wear in uncemented acetabular cups after Total Hip Arthroplasty. A case series
    Jasqui Remba, Salomon
    Esquivel Gomez, Ricardo
    Gutierrez Ambriz, Luis
    Portman Santos, Daniel
    Baley Amiga, Isaac
    INTERNATIONAL JOURNAL OF SURGERY CASE REPORTS, 2021, 81
  • [8] Comparison of metal on metal versus polyethylene–ceramic bearing in uncemented total hip arthroplasty in patients with haemophilic arthropathy
    Joannis Panotopoulos
    Cihan Ay
    Reinhard Schuh
    Stephan Domayer
    Philipp Funovics
    Klemens Trieb
    Hugo Wanivenhaus
    Reinhard Windhager
    International Orthopaedics, 2014, 38 : 1369 - 1373
  • [9] Ceramic on ceramic bearings in total hip arthroplasty
    Buchanan, JM
    BIOCERAMICS 15, 2003, 240-2 : 793 - 796
  • [10] Comparison of metal on metal versus polyethylene-ceramic bearing in uncemented total hip arthroplasty in patients with haemophilic arthropathy
    Panotopoulos, Joannis
    Ay, Cihan
    Schuh, Reinhard
    Domayer, Stephan
    Funovics, Philipp
    Trieb, Klemens
    Wanivenhaus, Hugo
    Windhager, Reinhard
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (07) : 1369 - 1373