Vascular response to bioresorbable polymer sirolimus-eluting stent vs. permanent polymer everolimus-eluting stent at 9-month follow-up: an optical coherence tomography sub-study from the CENTURY II trial

被引:30
作者
Kuramitsu, Shoichi [1 ]
Kazuno, Yoshio [1 ]
Sonoda, Shinjo [2 ]
Domei, Takenori [1 ]
Jinnouchi, Hiroyuki [1 ]
Yamaji, Kyohei [1 ]
Soga, Yoshimitsu [1 ]
Shirai, Shinichi [1 ]
Ando, Kenji [1 ]
Saito, Shigeru [3 ]
机构
[1] Kokura Mem Hosp, Dept Cardiol, Kokurakita Ku, 3-2-1 Asano, Kitakyushu, Fukuoka 8028555, Japan
[2] Univ Occupat & Environm Hlth Japan, Sch Med, Dept Internal Med 2, Kitakyushu, Fukuoka, Japan
[3] Shonan Kamakura Gen Hosp, Cardiol & Catheterizat Labs, Kamakura, Kanagawa, Japan
关键词
Bioresorbable polymer; Sirolimus-eluting stent; Optical coherence tomography; Coronary artery disease; DURABLE-POLYMER; THROMBOSIS; COVERAGE; RISK;
D O I
10.1093/ehjci/jev203
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims The Ultimaster bioresorbable polymer sirolimus-eluting stent (BP-SES) is a newly developed drug-eluting stent (DES) that consists of a thin-strut, cobalt chromium with bioresorbable polymer coated only albuminally. We sought to compare tissue coverage in coronary lesions treated with BP-SES with the XIENCE permanent polymer everolimus-eluting stent (PP-EES) using optical coherence tomography (OCT). Methods and results A total of 36 patients participated in the CENTURY II trial in our institution and were randomly assigned to BP-SES (n = 15) and PP-EES (n = 21). Of these, 27 patients (13 BP-SES and 14 PP-EES) underwent OCT at 9-month follow-up. Tissue coverage and apposition were assessed on each strut, and the results in both groups were compared using multilevel logistic or linear regression models with randomeffects at three levels: patient, lesion, and struts. A total of 6450 struts (BP-SES, n = 2951; PP-EES, n = 3499) were analysed. Thirty and 79 uncovered struts (1.02 and 2.26%, P = 0.35), and 3 and 4 malapposed struts (0.10 and 0.11%, P = 0.94) were found in BP-SES and PP-EES groups, respectively. Mean neointimal thickness did not significantly differ between both groups (110 +/- 10 vs. 93 +/- 10 mu m, P = 0.22). No significant differences in per cent neointimal volume obstruction (13.2 +/- 4.6 vs. 10.5 +/- 4.9%, P = 0.14) or other areas-volumetric parameters were detected between both groups. Conclusion BP-SES shows an excellent vascular healing response at 9-month follow-up, which is similar to PP-EES.
引用
收藏
页码:34 / 40
页数:7
相关论文
共 22 条
  • [1] New Drug-Eluting Stents An Overview on Biodegradable and Polymer-Free Next-Generation Stent Systems
    Abizaid, Alexandre
    Costa, J. Ribamar, Jr.
    [J]. CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (04) : 384 - 393
  • [2] STACCATO (Assessment of Stent sTrut Apposition and Coverage in Coronary ArTeries with Optical coherence tomography in patients with STEMI, NSTEMI and stable/unstable angina undergoing everolimus vs. biolimus A9-eluting stent implantation): a randomised controlled trial
    Adriaenssens, Tom
    Ughi, Giovanni J.
    Dubois, Christophe
    De Cock, Dries
    Onsea, Kevin
    Bennett, Johan
    Wiyono, Stefanus
    Sinnaeve, Peter
    Coosemans, Mark
    Ferdinande, Bert
    Belmans, Ann
    D'hooge, Jan
    Desmet, Walter
    [J]. EUROINTERVENTION, 2016, 11 (14) : E1619 - E1626
  • [3] Barbato E, 2015, EUROINTERVENTION, V11, P541, DOI 10.4244/EIJY14M08_06
  • [4] An optical coherence tomography study of a biodegradable vs. durable polymer-coated limus-eluting stent: a LEADERS trial sub-study
    Barlis, Peter
    Regar, Evelyn
    Serruys, Patrick W.
    Dimopoulos, Konstantinos
    van der Giessen, Willem J.
    van Geuns, Robert-Jan M.
    Ferrante, Giuseppe
    Wandel, Simon
    Windecker, Stephan
    van Es, Gerrit-Anne
    Eerdmans, Pedro
    Jueni, Peter
    di Mario, Carlo
    [J]. EUROPEAN HEART JOURNAL, 2010, 31 (02) : 165 - 176
  • [5] Pathological correlates of late drug-eluting stent thrombosis - Strut coverage as a marker of endothelialization
    Finn, Aloke V.
    Joner, Michael
    Nakazawa, Gaku
    Kolodgie, Frank
    Newell, John
    John, Mike C.
    Gold, Herman K.
    Virmani, Renu
    [J]. CIRCULATION, 2007, 115 (18) : 2435 - 2441
  • [6] Tissue coverage of a hydrophilic polymer-coated zotarolimus-eluting stent vs. a fluoropolymer-coated everolimus-eluting stent at 13-month follow-up: an optical coherence tomography substudy from the RESOLUTE All Comers trial
    Gutierrez-Chico, Juan Luis
    van Geuns, Robert Jan
    Regar, Evelyn
    van der Giessen, Willem J.
    Kelbaek, Henning
    Saunamaki, Kari
    Escaned, Javier
    Gonzalo, Nieves
    di Mario, Carlo
    Borgia, Francesco
    Nueesch, Eveline
    Garcia-Garcia, Hector M.
    Silber, Sigmund
    Windecker, Stephan
    Serruys, Patrick W.
    [J]. EUROPEAN HEART JOURNAL, 2011, 32 (19) : 2454 - 2463
  • [7] Optical coherence evaluation of everolimus-eluting stents 8 months after implantation
    Inoue, Takumi
    Shite, Junya
    Yoon, Junghan
    Shinke, Toshiro
    Otake, Hiromasa
    Sawada, Takahiro
    Kawamori, Hiroyuki
    Katoh, Hiroki
    Miyoshi, Naoki
    Yoshino, Naoki
    Kozuki, Amane
    Hariki, Hirotoshi
    Hirata, Ken-ichi
    [J]. HEART, 2011, 97 (17) : 1379 - 1384
  • [8] Pathology of drug-eluting stents in humans - Delayed healing and late thrombotic risk
    Joner, Michael
    Finn, Aloke V.
    Farb, Andrew
    Mont, Erik K.
    Kolodgie, Frank D.
    Ladich, Elena
    Kutys, Robert
    Skorija, Kristi
    Gold, Herman K.
    Virmani, Renu
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (01) : 193 - 202
  • [9] Biodegradable-polymer drug-eluting stents vs. bare metal stents vs. durable-polymer drug-eluting stents: a systematic review and Bayesian approach network meta-analysis
    Kang, Si-Hyuck
    Park, Kyung Woo
    Kang, Do-Yoon
    Lim, Woo-Hyun
    Park, Kyung Taek
    Han, Jung-Kyu
    Kang, Hyun-Jae
    Koo, Bon-Kwon
    Oh, Byung-Hee
    Park, Young-Bae
    Kandzari, David E.
    Cohen, David J.
    Hwang, Seung-Sik
    Kim, Hyo-Soo
    [J]. EUROPEAN HEART JOURNAL, 2014, 35 (17) : 1147 - +
  • [10] Vascular Response to Drug-Eluting Stent With Biodegradable vs. Durable Polymer - Optical Coherence Tomography Substudy of the NEXT
    Kubo, Takashi
    Akasaka, Takashi
    Kozuma, Ken
    Kimura, Kazuo
    Fusazaki, Tetsuya
    Okura, Hiroyuki
    Shinke, Toshiro
    Ino, Yasushi
    Hasegawa, Takao
    Takashima, Hiroaki
    Takamisawa, Itaru
    Yamaguchi, Hiroshi
    Igarashi, Keiichi
    Kadota, Kazushige
    Tanabe, Kengo
    Nakagawa, Yoshihisa
    Muramatsu, Toshiya
    Morino, Yoshihiro
    Kimura, Takeshi
    [J]. CIRCULATION JOURNAL, 2014, 78 (10) : 2408 - 2414