Multiobjective optimization in combinatorial wind farms system integration and resistive SFCL using analytical hierarchy process

被引:16
作者
Moghadasi, Amirhasan [1 ]
Sarwat, Arif [1 ]
Guerrero, Josep M. [2 ]
机构
[1] Florida Int Univ, Energy Syst Res Lab, Miami, FL 33174 USA
[2] Aalborg Univ, Dept Energy Technol, Aalborg, Denmark
关键词
Low voltage ride-through; Multi-objective optimization; Superconducting fault current limiter; Wind farm; LOW-VOLTAGE-RIDE; FAULT-CURRENT LIMITERS; THROUGH ENHANCEMENT; POWER-SYSTEM; TURBINE; ENERGY; PERFORMANCE; GENERATORS; DESIGN; SCHEME;
D O I
10.1016/j.renene.2016.03.073
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper presents a positive approach for low voltage ride-through (LVRT) improvement of the permanent magnet synchronous generator (PMSG) based on a large wind power plant (WPP) of 50 MW. The proposed method utilizes the conventional current control strategy to provide a reactive power requirement and retain the active power production during and after the fault for the grid codes compliance. Besides that, a resistive superconducting fault current limiter (RSFCL) as an additional self healing support is applied outside the WPP to further increase the rated active power of the installation, thereby enhance the dc-link voltage smoothness, as well as the LVRT capability of the 50 MW WPP. This is achieved by limiting the exceed fault current and diminishing the voltage dip level, leading to increase the voltage safety margin of the LVRT curve. Furthermore, the effect of the installed RSFCL on the extreme load reduction is effectively demonstrated. A large WPP has a complicated structure using several components, and the inclusion of RSFCL composes this layout more problematic for optimal performance of the system. Hence, the most-widely decision-making technique based on the analytic hierarchy process (AHP) is proposed for the optimal design of the combinatorial RSFCL and 50 MW WPP to compute the three-dimensional alignment in Pareto front at the end of the optimization run. The numerical simulations verify effectiveness of the proposed approach, using the Pareto optimality concept. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:366 / 382
页数:17
相关论文
共 39 条
  • [1] Adhikari J, 2015, INT C POWER ELECT DR, P773, DOI 10.1109/PEDS.2015.7203477
  • [2] Use of Stored Energy in PMSG Rotor Inertia for Low-Voltage Ride-Through in Back-to-Back NPC Converter-Based Wind Power Systems
    Alepuz, Salvador
    Calle, Alejandro
    Busquets-Monge, Sergio
    Kouro, Samir
    Wu, Bin
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (05) : 1787 - 1796
  • [3] Amei K, 2002, PCC-OSAKA 2002: PROCEEDINGS OF THE POWER CONVERSION CONFERENCE-OSAKA 2002, VOLS I - III, P1447, DOI 10.1109/PCC.2002.998186
  • [4] Analysis of Energy Dissipation in Resistive Superconducting Fault-Current Limiters for Optimal Power System Performance
    Blair, Steven M.
    Booth, Campbell D.
    Singh, Nand K.
    Burt, Graeme M.
    Bright, Chris G.
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2011, 21 (04) : 3452 - 3457
  • [5] Deng F., 2009, P 35 ANN C IEEE IND, P621
  • [6] Eckroad S., 2009, Superconducting fault current limiters technology watch 2009
  • [7] Improving Fault Ride-Through Capability of DFIG-Based Wind Turbine Using Superconducting Fault Current Limiter
    Elshiekh, Mariam E.
    Mansour, Diaa-Eldin A.
    Azmy, Ahmed M.
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2013, 23 (03)
  • [8] Performance Enhancement of Actively Controlled Hybrid DC Microgrid Incorporating Pulsed Load
    Farhadi, Mustafa
    Mohammed, Osama A.
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2015, 51 (05) : 3570 - 3578
  • [9] Event-Based Protection Scheme for a Multiterminal Hybrid DC Power System
    Farhadi, Mustafa
    Mohammed, Osama A.
    [J]. IEEE TRANSACTIONS ON SMART GRID, 2015, 6 (04) : 1658 - 1669
  • [10] Adaptive Energy Management in Redundant Hybrid DC Microgrid for Pulse Load Mitigation
    Farhadi, Mustafa
    Mohammed, Osama
    [J]. IEEE TRANSACTIONS ON SMART GRID, 2015, 6 (01) : 54 - 62