Diode laser absorption spectroscopy measurement of linestrengths and pressure broadening coefficients of the methane 2v3 band at elevated temperatures

被引:54
作者
Gharavi, M [1 ]
Buckley, SG [1 ]
机构
[1] Univ Calif San Diego, Dept Mech & Aerosp Engn, La Jolla, CA 92093 USA
关键词
CH4; spectroscopy; absorption linestrength; collisional broadening; temperature dependence of the collisional half-width; Voigt function; tunable diode laser absorption spectroscopy; combustion diagnostics;
D O I
10.1016/j.jms.2004.07.016
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
A diode laser sensor based on absorption spectroscopy has been developed for the measurement of spectroscopic parameters in the R(3) and R(4) manifolds of 2nu(3) band of CH4. Individual linestrengths of each transition are determined for a range of temperatures. In addition, collision-broadened half-widths for CO2, N-2, H2O, CH4, and CO collision partners are measured as a function of temperature and pressure for these strongly overlapped transitions. From this, temperature dependence of the collision half-width for each collision partner is determined. Using a new method for calculation of collisional broadening at high temperatures for strongly overlapped transitions makes these transitions accessible for spectroscopy. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:78 / 88
页数:11
相关论文
共 17 条
[1]   MULTIPLEXED DIODE-LASER SENSOR SYSTEM FOR SIMULTANEOUS H2O, O-2, AND TEMPERATURE-MEASUREMENTS [J].
BAER, DS ;
HANSON, RK ;
NEWFIELD, ME ;
GOPAUL, NKJM .
OPTICS LETTERS, 1994, 19 (22) :1900-1902
[2]   TUNABLE-DIODE-LASER FREQUENCY-MODULATION SPECTROSCOPY USING BALANCED HOMODYNE DETECTION [J].
CARLISLE, CB ;
COOPER, DE .
OPTICS LETTERS, 1989, 14 (23) :1306-1308
[3]   TRACE GAS-DETECTION WITH SHORT-EXTERNAL-CAVITY INGAASP DIODE-LASER TRANSMITTER MODULES OPERATING AT 1.58 MU-M [J].
CASSIDY, DT ;
BONNELL, LJ .
APPLIED OPTICS, 1988, 27 (13) :2688-2693
[4]   TEMPERATURE-DEPENDENCE OF HALF WIDTHS OF SOME SELF-GAS BROADENED AND FOREIGN-GAS-BROADENED LINES OF METHANE [J].
DARNTON, L ;
MARGOLIS, JS .
JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 1973, 13 (10) :969-976
[5]   MEASUREMENTS OF NITROGEN-BROADENED, HYDROGEN-BROADENED, AND HELIUM-BROADENED WIDTHS OF METHANE LINES AT 9030-9120 CM-1 [J].
FOX, K ;
JENNINGS, DE .
JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 1985, 33 (03) :275-280
[6]   MEASUREMENTS OF ARGON-BROADENED, HELIUM-BROADENED, HYDROGEN-BROADENED, AND NITROGEN-BROADENED WIDTHS OF METHANE LINES NEAR 9000 CM-1 [J].
FOX, K ;
JENNINGS, DE ;
STERN, EA ;
HUBBARD, R .
JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 1988, 39 (06) :473-476
[7]   HIGH-RESOLUTION SPECTROSCOPY OF COMBUSTION GASES USING A TUNABLE IR DIODE-LASER [J].
HANSON, RK ;
KUNTZ, PA ;
KRUGER, CH .
APPLIED OPTICS, 1977, 16 (08) :2045-2048
[8]   Diode laser sensor for measurements of CO, CO2, and CH4 in combustion flows [J].
Mihalcea, RM ;
Baer, DS ;
Hanson, RK .
APPLIED OPTICS, 1997, 36 (33) :8745-8752
[9]   Tunable diode-laser absorption measurements of methane at elevated temperatures [J].
Nagali, V ;
Chou, SI ;
Baer, DS ;
Hanson, RK ;
Segall, J .
APPLIED OPTICS, 1996, 35 (21) :4026-4032
[10]   EMPIRICAL FITS TO VOIGT LINE-WIDTH - BRIEF REVIEW [J].
OLIVERO, JJ ;
LONGBOTHUM, RL .
JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 1977, 17 (02) :233-236