A novel-integrated quality assurance phantom for radiographic and nonradiographic radiotherapy localization and positioning systems

被引:11
|
作者
Yu, Amy S. [1 ]
Fowler, Tyler L. [1 ]
Dubrowski, Piotr [1 ]
机构
[1] Stanford Univ, Dept Radiat Oncol, Sch Med, Stanford, CA 94305 USA
关键词
localization positioning system; nonradiographic and radiographic QA; quality assurance; radiotherapy; LINEAR-ACCELERATOR; REAL-TIME; RADIOSURGERY;
D O I
10.1002/mp.12950
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeVarious localization and positioning systems utilizing radiographic or nonradiographic methods have been developed to improve the accuracy of radiation treatment. Each quality assurance (QA) procedure requires its own phantom and is independent from each other, so the deviation between each system is unavailable. The purpose of this work is to develop and evaluate a single-integrated QA phantom for different localization and positioning systems. MethodsThe integrated phantom was designed in three-dimensional (3D) CAD software and 3D printed. The phantom was designed with laser alignment marks, a raised letter S on the anterior surface for optical surface monitoring system registration, a core for radiofrequency (RF) tracking system alignment, eight internal fiducials for image alignment, and an isocentric bearing for Winston-Lutz test. Tilt legs and rotational stage were designed for rotational verification of optical surface mapping system and RF tracking system, respectively. The phantom was scanned using a CT scanner and a QA plan was created. This prototype phantom was evaluated against established QA techniques. ResultsThe QA result between the proposed procedure and established QA technique are 1.12 0.31 and 1.14 +/- 0.31 mm, respectively, for RF tracking system and 0.18 +/- 0.06 and 0.18 +/- 0.05 mm for Winston-Lutz test. There is no significant difference for the QA results between the established QA and proposed procedure (P > 0.05, t test). The accuracy of rotational verification for surface mapping system and RF tracking system are less than 0.5 and 1 degrees compared the predefined value. The isocenter deviation of each location system is around l mm. ConclusionWe have designed and evaluated a novel-integrated phantom for radiographic and nonradiographic localization and positioning systems for radiotherapy. With this phantom, we will reduce the variation in measurements and simplify the QA procedures.
引用
收藏
页码:2857 / 2863
页数:7
相关论文
共 42 条
  • [21] A novel surface imaging system for patient positioning and surveillance during radiotherapy A phantom study and clinical evaluation
    Stieler, F.
    Wenz, F.
    Shi, M.
    Lohr, F.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2013, 189 (11) : 938 - 944
  • [22] Simple, inexpensive, and ergonomic phantom for quality assurance control of MRI guided Focused Ultrasound systems
    Anastasia Antoniou
    Christakis Damianou
    Journal of Ultrasound, 2023, 26 : 401 - 408
  • [23] Simple, inexpensive, and ergonomic phantom for quality assurance control of MRI guided Focused Ultrasound systems
    Antoniou, Anastasia
    Damianou, Christakis
    JOURNAL OF ULTRASOUND, 2023, 26 (02) : 401 - 408
  • [24] Quality assurance of ultrasound imaging systems for target localization and online setup corrections
    Tome, Wolfgang A.
    Orton, Nigel P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (01): : S53 - S56
  • [25] The development and testing of a novel spherical radiotherapy phantom system for the commissioning and patient-specific quality assurance of mono-isocentric multiple mets SRS plans
    McKenna, John T.
    MEDICAL PHYSICS, 2021, 48 (01) : 105 - 113
  • [26] A versatile phantom for quality assurance in the UK Medical Research Council (MRC) RT01 trial (ISRCTN47772397) in conformal radiotherapy for prostate cancer
    Moore, A. Rollo
    Warrington, A. P. Jim
    Aird, Edwin G. A.
    Bidmead, A. Margaret
    Dearnaley, David P.
    RADIOTHERAPY AND ONCOLOGY, 2006, 80 (01) : 82 - 85
  • [27] A novel compound 6D-offset simulating phantom and quality assurance program for stereotactic image-guided radiation therapy system
    Ngar, Dennis Yuen-Kan
    Cheung, Michael Lok-Man
    Kam, Michael -Koon-Ming
    Poon, Wai-Sang
    Chan, Anthony Tak-Cheung
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (06): : 100 - 116
  • [28] On-line quality assurance of rotational radiotherapy treatment delivery by means of a 2D ion chamber array and the Octavius phantom
    Van Esch, Ann
    Clermont, Christian
    Devillers, Magali
    Iori, Mauro
    Huyskens, Dominique P.
    MEDICAL PHYSICS, 2007, 34 (10) : 3825 - 3837
  • [29] Development of image quality assurance measures of the ExacTrac localization system using commercially available image evaluation software and hardware for image-guided radiotherapy
    Stanley, Dennis N.
    Papanikolaou, Nikos
    Gutierrez, Alonso N.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (06): : 81 - 91
  • [30] Characterization of a novel 3D printed patient specific phantom for quality assurance in cranial stereotactic radiosurgery applications
    Makris, D. N.
    Pappas, E. P.
    Zoros, E.
    Papanikolaou, N.
    Saenz, D. L.
    Kalaitzakis, G.
    Zourari, K.
    Efstathopoulos, E.
    Maris, T. G.
    Pappas, E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (10):