CO2 Laser Fabrication of PMMA Microfluidic Double T-Junction Device with Modified Inlet-Angle for Cost-Effective PCR Application

被引:19
作者
Nasser, Gamal A. [1 ]
El-Bab, Ahmed M. R. Fath [1 ,2 ]
Abdel-Mawgood, Ahmed L. [3 ,4 ]
Mohamed, Hisham [5 ]
Saleh, Abdelatty M. [6 ]
机构
[1] E JUST, Mechatron & Robot Dept, Alexandria 21934, Egypt
[2] Assiut Univ, Mech Engn Dept, Assiut 71515, Egypt
[3] E JUST, Biotechnol Dept, Alexandria 21934, Egypt
[4] Damanhour Univ, Inst Grad Studies & Environm Res, Damanhour 22511, Egypt
[5] Rensselaer Polytech Inst, Biomed Engn Dept, Troy, NY 12180 USA
[6] Kafrelsheikh Univ, Fac Aquat & Fisheries Sci, Fish Proc & Biotechnol Dept, Kafr Al Sheikh 33516, Egypt
关键词
droplet formation; PMMA; microchannel; ddPCR; CO2 laser micromachining; LIQUID-LIQUID FLOWS; MICROCHANNEL FABRICATION; GLASS; HYDRODYNAMICS; CHALLENGES; CHIPS;
D O I
10.3390/mi10100678
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The formation of uniform droplets and the control of their size, shape and monodispersity are of utmost importance in droplet-based microfluidic systems. The size of the droplets is precisely tuned by the channel geometry, the surface interfacial tension, the shear force and fluid velocity. In addition, the fabrication technique and selection of materials are essential to reduce the fabrication cost and time. In this paper, for reducing the fabrication cost Polymethyl methacrylate (PMMA) sheet is used with direct write laser technique by VERSA CO2 laser VLS3.5. This laser writing technique gives minimum channel width of about 160 mu m, which limit miniaturizing the droplet. To overcome this, modification on double T-junction (DTJ) channel geometry has been done by modifying the channel inlets angles. First, a two-dimensional (2D) simulation has been done to study the effect of the new channel geometry modification on droplet size, droplets distribution inside the channel, and its throughput. The fabricated modified DTJ gives the minimum droplet diameter of 39 +/- 2 mu m, while DTJ channel produced droplet diameter of 48 +/- 4 mu m at the same conditions. Moreover, the modified double T-junction (MDTJ) decreases the variation in droplets diameter at the same flow rates by 4.5-13% than DTJ. This low variation in the droplet diameter is suitable for repeatability of the DNA detection results. The MDTJ also enhanced the droplet generation frequency by 8-25% more than the DTJ channel. The uniformity of droplet distribution inside the channel was enhanced by 3-20% compared to the DTJ channel geometry. This fabrication technique eliminates the need for a photomask and cleanroom environment in addition shortening the cost and time. It takes only 20 min for fabrication. The minimum generated droplet diameter is within 40 mu m with more than 1000 droplets per second (at 10 mL/h. oil flow rate). The device is a high-throughput and low-cost micro-droplet formation aimed to be as a front-end to a dynamic droplet digital PCR (ddPCR) platform for use in resource-limited environment.
引用
收藏
页数:15
相关论文
共 67 条
  • [1] Hydrodynamics of Taylor flow in small channels: a review
    Angeli, P.
    Gavriilidis, A.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2008, 222 (05) : 737 - 751
  • [2] Mail-order microfluidics: evaluation of stereolithography for the production of microfluidic devices
    Au, Anthony K.
    Lee, Wonjae
    Folch, Albert
    [J]. LAB ON A CHIP, 2014, 14 (07) : 1294 - 1301
  • [3] Bandara T., 2017, 28 INT S TRANSP PHEN, P22
  • [4] High aspect ratio taper-free microchannel fabrication using femtosecond Bessel beams
    Bhuyan, M. K.
    Courvoisier, F.
    Lacourt, P. -A.
    Jacquot, M.
    Furfaro, L.
    Withford, M. J.
    Dudley, J. M.
    [J]. OPTICS EXPRESS, 2010, 18 (02): : 566 - 574
  • [5] A CONTINUUM METHOD FOR MODELING SURFACE-TENSION
    BRACKBILL, JU
    KOTHE, DB
    ZEMACH, C
    [J]. JOURNAL OF COMPUTATIONAL PHYSICS, 1992, 100 (02) : 335 - 354
  • [6] Fabrication and characterization of poly(methylmethacrylate) microfluidic devices bonded using surface modifications and solvents
    Brown, L
    Koerner, T
    Horton, JH
    Oleschuk, RD
    [J]. LAB ON A CHIP, 2006, 6 (01) : 66 - 73
  • [7] A temperature control method for shortening thermal cycling time to achieve rapid polymerase chain reaction (PCR) in a disposable polymer microfluidic device
    Bu, Minqiang
    Perch-Nielsen, Ivan R.
    Sorensen, Karen S.
    Skov, Julia
    Sun, Yi
    Bang, Dang Duong
    Pedersen, Michael E.
    Hansen, Mikkel F.
    Wolff, Anders
    [J]. JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2013, 23 (07)
  • [8] Advances in digital polymerase chain reaction (dPCR) and its emerging biomedical applications
    Cao, Lei
    Cui, Xingye
    Hu, Jie
    Li, Zedong
    Choi, Jane Ru
    Yang, Qingzhen
    Lin, Min
    Ying HuiLi
    Xu, Feng
    [J]. BIOSENSORS & BIOELECTRONICS, 2017, 90 : 459 - 474
  • [9] Droplet generation at Hele-Shaw microfluidic T-junction
    Chakraborty, I.
    Ricouvier, J.
    Yazhgur, P.
    Tabeling, P.
    Leshansky, A. M.
    [J]. PHYSICS OF FLUIDS, 2019, 31 (02)
  • [10] CO2 Laser Ablation of Microchannel on PMMA Substrate for Effective Fabrication of Microfluidic Chips
    Chen, X.
    Li, T.
    Shen, J.
    [J]. INTERNATIONAL POLYMER PROCESSING, 2016, 31 (02) : 233 - 238