CT morphological index provides incremental value to machine learning based CT-FFR for predicting hemodynamically significant coronary stenosis

被引:22
作者
Yu, Mengmeng [1 ]
Lu, Zhigang [2 ]
Li, Wenbin [1 ]
Wei, Meng [2 ]
Yan, Jing [3 ]
Zhang, Jiayin [1 ]
机构
[1] Shanghai Jiao Tong Univ, Peoples Hosp 6, Inst Diagnost & Intervent Radiol, 600 Yishan Rd, Shanghai 200233, Peoples R China
[2] Shanghai Jiao Tong Univ, Peoples Hosp 6, Dept Cardiol, 600 Yishan Rd, Shanghai 200233, Peoples R China
[3] Siemens Healthcare Ltd, 278 Zhouzhugong Rd, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
Coronary artery disease; Computed tomography; Duke jeopardy score; Minimal lumen diameter; Fractional flow reserve; FRACTIONAL FLOW RESERVE; TRANSLUMINAL ATTENUATION GRADIENT; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; DIAGNOSTIC-ACCURACY; ARTERY-DISEASE; FUNCTIONAL SEVERITY; GUIDED PCI; PERFORMANCE;
D O I
10.1016/j.ijcard.2018.01.075
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: To study the diagnostic performance of the ratio of Duke jeopardy score (DJS) to the minimal lumen diameter (MLD) at coronary computed tomographic angiography (CCTA) and machine learning based CT-FFR for differentiating functionally significant from insignificant lesions, with reference to fractional flow reserve (FFR). Methods and results: Patients who underwent both coronary CTA and FFR measurement at invasive coronary angiography (ICA) within 2 weeks were retrospectively included in our study. CT-FFR, DJS/MLDCT ratio, along with other parameters, including minimal luminal area (MLA), MLD, lesion length (LL), diameter stenosis, area stenosis, plaque burden, and remodeling index of lesions, were recorded. Lesions with FFR <= 0.8 were considered to be functionally significant. One hundred and twenty-nine patients with 166 lesions were ultimately included for analysis. The LL, diameter stenosis, area stenosis, plaque burden, DJS and DJS/MLDCT ratio were all significantly longer or larger in the group of FFR <= 0.8 (p < 0.001 for all), while smaller MLA, MLD and CT-FFR value were also noted (p < 0.001 for all). CT-FFR and DJS/MLDCT ratio showed the largest AUC among all single parameters (AUC = 0.85 and AUC = 0.83, respectively; p < 0.001 for both) for diagnosing functionally significant stenosis. Combining CT-FFR and DJS/MLDCT ratio provided incremental value for discrimination between flow-limiting and non-flow-limiting coronary lesions and yielded the best diagnostic performance (accuracy of 83.7%). Conclusions: The combination of ML-based CT-FFR and DJS/MLDCT allows accurate non-invasive discrimination between flow-limiting and non-flow-limiting coronary lesions. (c) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:256 / 261
页数:6
相关论文
共 29 条
[11]   A machine-learning approach for computation of fractional flow reserve from coronary computed tomography [J].
Itu, Lucian ;
Rapaka, Saikiran ;
Passerini, Tiziano ;
Georgescu, Bogdan ;
Schwemmer, Chris ;
Schoebinger, Max ;
Flohr, Thomas ;
Sharma, Puneet ;
Comaniciu, Dorin .
JOURNAL OF APPLIED PHYSIOLOGY, 2016, 121 (01) :42-52
[12]   Diagnostic Performance of Transluminal Attenuation Gradient and Noninvasive Fractional Flow Reserve Derived from 320-Detector Row CT Angiography to Diagnose Hemodynamically Significant Coronary Stenosis: An NXT Substudy [J].
Ko, Brian S. ;
Wong, Dennis T. L. ;
Norgaard, Bjarne L. ;
Leong, Darryl P. ;
Cameron, James D. ;
Gaur, Sara ;
Marwan, Mohamed ;
Achenbach, Stephan ;
Kuribayashi, Sachio ;
Kimura, Takeshi ;
Meredith, Ian T. ;
Seneviratne, Sujith K. .
RADIOLOGY, 2016, 279 (01) :75-83
[13]   Fractional flow reserve derived from coronary computed tomography angiography reclassification rate using value distal to lesion compared to lowest value [J].
Kueh, Shaw Hua ;
Mooney, John ;
Ohana, Mickael ;
Kim, Ung ;
Blanke, Philipp ;
Grover, Rominder ;
Sellers, Stephanie ;
Ellis, Jennifer ;
Murphy, Darra ;
Hague, Cameron ;
Bax, Jeroen J. ;
Norgaard, Bjarne L. ;
Rabbat, Mark ;
Leipsic, Jonathon A. .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2017, 11 (06) :462-467
[14]   Influence of the Amount of Myocardium Subtended by a Stenosis on Fractional Flow Reserve [J].
Leone, Antonio Maria ;
De Caterina, Alberto Ranieri ;
Basile, Eloisa ;
Gardi, Andrea ;
Laezza, Domenico ;
Mazzari, Mario Attilio ;
Mongiardo, Rocco ;
Kharbanda, Rajesh ;
Cuculi, Florim ;
Porto, Italo ;
Niccoli, Giampaolo ;
Burzotta, Francesco ;
Trani, Carlo ;
Banning, Adrian Paul ;
Rebuzzi, Antonio Giuseppe ;
Crea, Filippo .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (01) :29-36
[15]   Accuracy of Fractional Flow Reserve Measurements in Clinical Practice Observations From a Core Laboratory Analysis [J].
Matsumura, Mitsuaki ;
Johnson, Nils P. ;
Fearon, William F. ;
Mintz, Gary S. ;
Stone, Gregg W. ;
Oldroyd, Keith G. ;
De Bruyne, Bernard ;
Pijls, Nico H. J. ;
Maehara, Akiko ;
Jeremias, Allen .
JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (14) :1392-1401
[16]   Diagnostic Performance of Coronary Angiography by 64-Row CT [J].
Miller, Julie M. ;
Rochitte, Carlos E. ;
Dewey, Marc ;
Arbab-Zadeh, Armin ;
Niinuma, Hiroyuki ;
Gottlieb, Ilan ;
Paul, Narinder ;
Clouse, Melvin E. ;
Shapiro, Edward P. ;
Hoe, John ;
Lardo, Albert C. ;
Bush, David E. ;
de Roos, Albert ;
Cox, Christopher ;
Brinker, Jeffery ;
Lima, Joao A. C. .
NEW ENGLAND JOURNAL OF MEDICINE, 2008, 359 (22) :2324-2336
[17]   Diagnostic Accuracy of Fractional Flow Reserve From Anatomic CT Angiography [J].
Min, James K. ;
Leipsic, Jonathon ;
Pencina, Michael J. ;
Berman, Daniel S. ;
Koo, Bon-Kwon ;
van Mieghem, Carlos ;
Erglis, Andrejs ;
Lin, Fay Y. ;
Dunning, Allison M. ;
Apruzzese, Patricia ;
Budoff, Matthew J. ;
Cole, Jason H. ;
Jaffer, Farouc A. ;
Leon, Martin B. ;
Malpeso, Jennifer ;
Mancini, G. B. John ;
Park, Seung-Jung ;
Schwartz, Robert S. ;
Shaw, Leslee J. ;
Mauri, Laura .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2012, 308 (12) :1237-1245
[18]   Diagnostic Performance of Noninvasive Fractional Flow Reserve Derived From Coronary Computed Tomography Angiography in Suspected Coronary Artery Disease The NXT Trial (Analysis of Coronary Blood Flow Using CT Angiography: Next Steps) [J].
Norgaard, Bjarne L. ;
Leipsic, Jonathon ;
Gaur, Sara ;
Seneviratne, Sujith ;
Ko, Brian S. ;
Ito, Hiroshi ;
Jensen, Jesper M. ;
Mauri, Laura ;
De Bruyne, Bernard ;
Bezerra, Hiram ;
Osawa, Kazuhiro ;
Marwan, Mohamed ;
Naber, Christoph ;
Erglis, Andrejs ;
Park, Seung-Jung ;
Christiansen, Evald H. ;
Kaltoft, Anne ;
Lassen, Jens F. ;
Botker, Hans Erik ;
Achenbach, Stephan .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) :1145-1155
[19]   Measurement of fractional flow reserve to assess the functional severity of coronary-artery stenoses [J].
Pijls, NHJ ;
DeBruyne, B ;
Peels, K ;
VanderVoort, PH ;
Bonnier, HJRM ;
Bartunek, J ;
Koolen, JJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1996, 334 (26) :1703-1708
[20]   Iodinated Contrast Opacification Gradients in Normal Coronary Arteries Imaged With Prospectively ECG-Gated Single Heart Beat 320-Detector Row Computed Tomography [J].
Steigner, Michael L. ;
Mitsouras, Dimitrios ;
Whitmore, Amanda G. ;
Otero, Hansel J. ;
Wang, Chunliang ;
Buckley, Orla ;
Levit, Noah A. ;
Hussain, Alia Z. ;
Cai, Tianxi ;
Mather, Richard T. ;
Smedby, Orjan ;
DiCarli, Marcelo F. ;
Rybicki, Frank J. .
CIRCULATION-CARDIOVASCULAR IMAGING, 2010, 3 (02) :179-186