Gestational-age-adjusted reference values for the modified myocardial performance index for evaluation of fetal left cardiac function

被引:120
作者
Hernandez-Andrade, E.
Figueroa-Diesel, H.
Kottman, C.
Illanes, S.
Arraztoa, J.
Acosta-Rojas, R.
Gratacos, E.
机构
[1] Hosp Clin Barcelona, Dept Obstet, ICGON, Fetal Med Res Grp, Barcelona 08028, Spain
[2] Univ Barcelona, Fetal & Perinatal Med Grp, IDIBAPS, Barcelona, Spain
[3] Univ Los Andes, Dept Obstet Gynecol & Reprod Med, Fetal Med Unit, Santiago, Chile
关键词
Doppler; fetal cardiac function; modified myocardial performance index;
D O I
10.1002/uog.3947
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective It has been shown that the modified myocardial performance index (Mod-MPI) is associated with higher reproducibility than conventional MPI because it uses mitral and aortic valve 'clicks' to calculate each time period. We aimed to construct normal reference values for the Mod-MPI after 19 weeks' gestation. Methods The Mod-MPI was calculated in the left ventricle of 557 normal fetuses at 19-39 weeks' gestation. The isovolumetric contraction time (ICT), isovolumetric relaxation time (IRT) and ejection time (ET) were measured using the Doppler signals (clicks) of the opening and closing of the mitral and aortic valves as landmarks. Mod-MPI was calculated as (ICT + IRT)/ET. Results Throughout gestation, there was a small increase in the Mod-MPI (at 19 weeks it was 0.35 +/- 0.027 (mean +/- SD); at 39 weeks, 0.37 +/- 0.029; Mod-MPI = 0.33 + 0.001 x gestational age (GA) (weeks), r(2) = 0.017). Of the three components, ICT remained constant, IRT increased (IRT = 0.028 + 2.52 x GA (weeks)), and ET slightly decreased (ET = 0. 184 - 3.6S x GA (weeks)). fetal heart rate (FHR) bad no effect on the Mod-MPI, but the duration of IRT, ICT and ET decreased by 13-15% when FHR increased from 130 to 160 beats per minute. Conclusion The GA-adjusted reference values for the Mod-MPI and the three time periods used for its calculation can be applied to fetal cardiac evaluation in the presence of pregnancy-associated complications. Copyright (c) 2007 ISUOG. Published by John Wiley & Sons, Ltd.
引用
收藏
页码:321 / 325
页数:5
相关论文
共 19 条
[1]   CHARTS OF FETAL SIZE .1. METHODOLOGY [J].
ALTMAN, DG ;
CHITTY, LS .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1994, 101 (01) :29-34
[2]   Venous Doppler in the assessment of fetal cardiovascular status [J].
Baschat, Ahmet Alexander ;
Harman, Chris R. .
CURRENT OPINION IN OBSTETRICS & GYNECOLOGY, 2006, 18 (02) :156-163
[3]   Importance of the index of myocardial performance in evaluation of left ventricular function [J].
Dagdelen, S ;
Eren, N ;
Karabulut, H ;
Caglar, N .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2002, 19 (04) :273-278
[4]   Importance of left ventricular activation in determining myocardial performance (Tei) index: comparison with total isovolumic time [J].
Duncan, AM ;
Francis, DP ;
Henein, MY ;
Gibson, DG .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2004, 95 (2-3) :211-217
[5]   Quantitative assessment of fetal ventricular function: Establishing normal values of the myocardial performance index in the fetus [J].
Eidem, BW ;
Edwards, JM ;
Cetta, F .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2001, 18 (01) :9-13
[6]   Fetal congestive heart failure: correlation of Tei-Index and Cardiovascular-Score [J].
Falkensammer, CB ;
Paul, J ;
Huhta, JC .
JOURNAL OF PERINATAL MEDICINE, 2001, 29 (05) :390-398
[7]   The unrecognized physiological and clinical significance of the fetal aortic isthmus [J].
Fouron, JC .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2003, 22 (05) :441-447
[8]   Fetal cardiac function assessed by Doppler myocardial performance index (Tei Index) [J].
Friedman, D ;
Buyon, J ;
Kim, M ;
Glickstein, JS .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2003, 21 (01) :33-36
[9]   The prevalence and clinical significance of tricuspid valve regurgitation in normally grown fetuses and those with intrauterine growth retardation [J].
Gembruch, U ;
Smrcek, JM .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1997, 9 (06) :374-382
[10]   A modified myocardial performance (Tei) index based on the use of valve clicks improves reproducibility of fetal left cardiac function assessment [J].
Hernandez-Andrade, E ;
López-Tenorio, J ;
Figueroa-Diesel, H ;
Sanin-Blair, J ;
Carreras, E ;
Cabero, L ;
Gratacos, E .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2005, 26 (03) :227-232