Telemetry-derived heart rate variability responses to a physical stressor

被引:10
作者
Montano, Alexandra [1 ]
Brown, Freddy [2 ]
Credeur, Daniel P. [3 ]
Williams, Michelle A. [1 ]
Stoner, Lee [2 ]
机构
[1] Harvard TH Chan Sch Publ Hlth, Dept Epidemiol, Boston, MA USA
[2] Massey Univ, Sch Sport & Exercise, Wellington, New Zealand
[3] Univ Southern Mississippi, Sch Human Performance & Recreat, Hattiesburg, MS USA
关键词
autonomic nervous system; cardiovascular function; concurrent validity; orthostatic challenge; reliability; reproducibility; BLOOD-PRESSURE RESPONSE; SHORT-TERM; RELIABILITY; RISK; REPRODUCIBILITY; HYPERTENSION; FAILURE; SYNCOPE; WOMEN; REST;
D O I
10.1111/cpf.12320
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Analysis of heart rate variability (HRV) responses to an orthostatic challenge can be used to investigate autonomic control of heart rate, an index of cardiovascular function. HRV is typically assessed using the electrocardiogram (ECG), which can be impractical for use with large population-based studies. Purpose To assess the validity and reliability of telemetry-derived HRV responses to an orthostatic challenge. Methods Twenty healthy adults (26 + 5 years, 45% male) were tested on three separate mornings. Following 20-min supine rest, R-R intervals were recorded using a telemetric device during three conditions: BASE, TILT and RECOVERY. ECG was simultaneously used on 1 day for validity comparison. Measures of HRV included the following: standard deviation of normal-to-normal intervals (SDNN), the root-mean-square of successive differences (RMSSD) and the low-frequency (LF) and high-frequency (HF) spectral power. Results For all parameters, there was excellent agreement between devices for BASE (r = 0.96-0.99), TILT (r = 0.89-1.00) and RECOVERY (r = 0.96-1.00). For the telemetric device, between-day intraclass coefficient values for RMSDD, SDNN and HF were all above the 0.75 criterion for each condition, indicating excellent between-day reliability. For each condition, the reliability coefficient, expressed as a percentage of the mean (RC%), was marginally lower (greater reliability) for RMSDD (RC% 11-13) and SDNN (RC% 10-12) compared to HF (RC% 12-17). However, SDNN did not significantly respond to the orthostatic challenge. Conclusion Telemetric HRV, particularly RMSDD and HF, can be used to provide a sensitive, valid and reliable assessment of autonomic control of heart rate.
引用
收藏
页码:421 / 427
页数:7
相关论文
共 40 条
[1]   Evaluation of Heart Rate Variation Analysis during Rest and Tilting in Patients with Temporal Lobe Epilepsy [J].
Ansakorpi, Hanna ;
Korpelainen, Juha T. ;
Suominen, Kalervo ;
Tolonen, Uolevi ;
Bloigu, Risto ;
Myllyla, Vilho V. ;
Isojarvi, Jouko I. T. .
NEUROLOGY RESEARCH INTERNATIONAL, 2011, 2011
[2]  
Blaber Andrew P, 2004, BMC Physiol, V4, P6, DOI 10.1186/1472-6793-4-6
[3]  
Bland JM, 1996, BRIT MED J, V313, P744
[4]  
Camm AJ, 1996, CIRCULATION, V93, P1043
[5]  
Carrasco S., 2003, Journal of Medical Engineering & Technology, V27, P241, DOI 10.1080/0309190031000111380
[6]   Spectral and time-domain analyses of heart-rate variability during head-upright tilt-table testing in children with neurally mediated syncope [J].
Evrengul, Harun ;
Tavli, Vedide ;
Evrengul, Havva ;
Tavli, Talat ;
Dursunoglu, Dursun .
PEDIATRIC CARDIOLOGY, 2006, 27 (06) :670-678
[7]  
Fleiss J.L., 1986, The Design and Analysis of Clinical Experiments, P1
[8]   Assessment of cardiovascular autonomic function [J].
Freeman, R .
CLINICAL NEUROPHYSIOLOGY, 2006, 117 (04) :716-730
[9]   Photoplethysmography pulse rate variability as a surrogate measurement of heart rate variability during non-stationary conditions [J].
Gil, E. ;
Orini, M. ;
Bailon, R. ;
Vergara, J. M. ;
Mainardi, L. ;
Laguna, P. .
PHYSIOLOGICAL MEASUREMENT, 2010, 31 (09) :1271-1290
[10]   Parameters of Heart Rate Variability Can Predict Prolonged Asystole before Head-Up Tilt Table Test [J].
Gursul, Erdal ;
Bayata, Serdar ;
Tuluce, Selcen Yakar ;
Berilgen, Rida ;
Safak, Ozgen ;
Ozdemir, Emre ;
Tuluce, Kamil .
ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2014, 19 (05) :477-482