Shake table tests of suspended ceilings to simulate the observed damage in the M s7.0 Lushan earthquake, China

被引:27
作者
Wang Duozhi [1 ]
Dai Junwu [1 ]
Qu Zhe [1 ]
Ning Xiaoqing [1 ]
机构
[1] China Earthquake Adm, Inst Engn Mech, Key Lab Earthquake Engn & Engn Vibrat, Harbin 150080, Peoples R China
基金
中国国家自然科学基金;
关键词
suspended ceiling; Lushan earthquake; Wenchuan earthquake; shake table test; wall closure; acoustic mineral fiber panel;
D O I
10.1007/s11803-016-0319-z
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Severe damage to suspended ceilings of metal grids and lay-in panels was observed in public buildings during the 2013 M (s)7.0 Lushan earthquake in China. Over the past several years, suspended ceilings have been widely used practice in public buildings throughout China, including government offices, schools and hospitals. To investigate the damage mechanism of suspended ceilings, a series of three-dimensional shake table tests was conducted to reproduce the observed damage. A full-scale reinforced concrete frame was constructed as the testing frame for the ceiling, which was single-story and infilled with brick masonry walls to represent the local construction of low-rise buildings. In general, the ceiling in the tests exhibited similar damage phenomena as the field observations, such as higher vulnerability of perimeter elements and extensive damage to the cross runners. However, it exhibited lower fragility in terms of peak ground/roof accelerations at the initiation of damage. Further investigations are needed to clarify the reasons for this behavior.
引用
收藏
页码:239 / 249
页数:11
相关论文
共 27 条
  • [1] [Anonymous], GB50223
  • [2] [Anonymous], 2008, 17742 GBT
  • [3] [Anonymous], 2012, 15 WORLD C EARTHQ EN
  • [4] [Anonymous], 1983, SEISM HAZ ASS NONSTR
  • [5] [Anonymous], 2010, GB50011-2010
  • [6] [Anonymous], EARTHQ INT MAP M7 0
  • [7] [Anonymous], 2012, 15 WORLD C EARTHQ EN
  • [8] [Anonymous], 2013, FIELD ASSESSMENT APR
  • [9] [Anonymous], IND DEC SUSP CEIL IN
  • [10] [Anonymous], NZ SOC EARTHQ ENG AN