Real-life outcome of implantable cardioverter-defibrillator and cardiac resynchronization defibrillator replacement/upgrade in a contemporary population: observations from the multicentre DECODE registry

被引:28
作者
Biffi, Mauro [1 ]
Ammendola, Ernesto [2 ]
Menardi, Endrj [3 ]
Parisi, Quintino [4 ]
Narducci, Maria Lucia [5 ]
De Filippo, Paolo [6 ]
Manzo, Michele [7 ]
Stabile, Giuseppe [8 ]
Potenza, Domenico Rosario [9 ]
Zanon, Francesco [10 ]
Quartieri, Fabio [11 ]
Rillo, Mariano [12 ]
Saporito, Davide [13 ]
Zaca, Valerio [14 ]
Berisso, Massimo Zoni [15 ]
Bertini, Matteo [16 ]
Tumietto, Fabio [1 ]
Malacrida, Maurizio [17 ]
Diemberger, Igor [1 ]
机构
[1] Azienda Osped Univ Bologna, Via Massarenti 9, I-40138 Bologna, Italy
[2] Univ Naples 2, Monaldi Hosp, Naples, Italy
[3] AS Osped S Croce & Carle, Cuneo, Italy
[4] Fdn Ric & Cura Giovanni Paolo II, Campobasso, Italy
[5] Fdn Policlin Univ A Gemelli IRCCS, Rome, Italy
[6] Osped Papa Giovanni XXIII Hosp, Bergamo, Italy
[7] AO Univ S Giovanni Di Dio & Ruggi DAragona, Salerno, Italy
[8] Clin Mediterranea, Naples, Italy
[9] Osped Casa Sollievo Sofferenza, San Giovanni Rotondo, Italy
[10] Osped S Maria Misericordia, Rovigo, Italy
[11] AO IRCCS Arcispedale S Maria Nuova Di Reggio Emil, Reggio Emilia, Italy
[12] Villa Verde Hosp, Taranto, Italy
[13] Infermi Hosp, Rimini, Italy
[14] AOU Senese, Arrhythmol Unit, Cardiovasc & Thorac Dept, Siena, Italy
[15] Osped PA Micone, Genova Sestri Ponente, Genoa, Italy
[16] Azienda Osped Univ Di Ferrara Arcispedale S Anna, Ferrara, Italy
[17] Boston Sci Italy, Milan, Italy
来源
EUROPACE | 2019年 / 21卷 / 10期
关键词
Implantable cardioverter-defibrillator; Cardiac resynchronisation therapy-defibrillator; Replacement; Upgrade; Complication; Infection; Registry; GENERATOR REPLACEMENT; CLINICAL-PRACTICE; POCKET HEMATOMA; INFECTION; THERAPY; COMPLICATIONS; PACEMAKER; TIME; MANAGEMENT; RATES;
D O I
10.1093/europace/euz166
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims The benefit of prolonged implantable cardioverter-defibrillator (ICD)/cardiac resynchronization therapy defibrillator (CRT-D) therapy following device replacement is hindered by clinical and procedure-related adverse events (AEs). Adverse events rate is highest in more complex devices and at upgrades, as per the REPLACE registry experience, but is changing owing to the improvement in device technology and medical care. We aimed at understanding the extent and type of AEs in a contemporary Italian population. Methods and results Detect long-term complications after ICD replacement (DECODE) was a prospective, single-arm, multicentre cohort study aimed at estimating medium- to long-term AEs in a large population of patients undergoing ICD/cardiac resynchronization defibrillator replacement/upgrade from 2013 to 2015. We prospectively analysed all clinical and device-related AEs at 12-month follow-up (FU) of 983 consecutive patients (median age 71 years, 76% male, 55% ischaemic, 47% CRT-D) followed for 353 +/- 49 days. Seven percent of the patients died (60.6% for cardiovascular reasons), whereas 104 AEs occurred; 43 (4.4%) patients needed at least one surgical action to treat the AE. Adverse events rates were 3.3/100 years lead-related, 3.4/100 years bleedings, and 1.6/100 years infective. The primary endpoint was predicted by hospitalization in the month prior to the procedure [hazard ratio (HR)=2.23, 1.16-4.29; 0.0169] and by upgrade (HR=1.75, 1.02-2.99, 0.0441). One hundred and twelve (11.4%) patients met the combined endpoint of death from any cause, cardiac implantable electronic device (CIED)-related infection, and surgical action/hospitalization required to treat the AE. Hospitalization within 30 days prior to the procedure (HR=2.07, 1.13-3.81; 0.0199), anticoagulation (HR=1.97, 1.26-3.07; 0.003), and ischaemic cardiomyopathy (HR=1.67, 95% confidence interval 1.06-2.63; P=0.0276) were associated with the combined endpoint during FU. Conclusions Adverse events following CIED replacement/upgrade are lower than previously reported, possibly owing to improved patients care. Hospitalization in the month prior to the procedure, upgrade, and clinical profile (anticoagulation, ischaemic cardiomyopathy) hint to increased risk, suggesting an individualized planning of the procedure to minimize overall AEs.
引用
收藏
页码:1527 / 1536
页数:10
相关论文
共 22 条
[1]   Repeated procedures at the generator pocket are a determinant of implantable cardioverter-defibrillator infection [J].
Arana-Rueda, Eduardo ;
Pedrote, Alonso ;
Frutos-Lopez, Manuel ;
Acosta, Juan ;
Jauregui, Beatriz ;
Garcia-Riesco, Lorena ;
Arce-Leon, Alvaro ;
Gomez-Pulido, Federico ;
Sanchez-Brotons, Juan A. ;
Gutierrez-Carretero, Encarnacion ;
de Alarcon-Gonzalez, Aristides .
CLINICAL CARDIOLOGY, 2017, 40 (10) :892-898
[2]   Is ventricular sensing always right, when it is left? [J].
Biffi, Mauro ;
de Zan, Giulia ;
Massaro, Giulia ;
Angeletti, Andrea ;
Martignani, Cristian ;
Boriani, Giuseppe ;
Diemberger, Igor ;
Ziacchi, Matteo .
CLINICAL CARDIOLOGY, 2018, 41 (09) :1238-1245
[3]   Meta-analysis of randomized controlled trials evaluating left ventricular vs. biventricular pacing in heart failure: effect on all-cause mortality and hospitalizations [J].
Boriani, Giuseppe ;
Gardini, Beatrice ;
Diemberger, Igor ;
Reggiani, Maria Letizia Bacchi ;
Biffi, Mauro ;
Martignani, Cristian ;
Ziacchi, Matteo ;
Valzania, Cinzia ;
Gasparini, Maurizio ;
Padeletti, Luigi ;
Branzi, Angelo .
EUROPEAN JOURNAL OF HEART FAILURE, 2012, 14 (06) :652-660
[4]   Detect Long-term Complications After ICD Replacement (DECODE): Rationale and Study Design of a Multicenter Italian Registry [J].
Diemberger, Igor ;
Parisi, Quintino ;
De Filippo, Paolo ;
Narducci, Maria Lucia ;
Zanon, Francesco ;
Potenza, Domenico Rosario ;
Ciaramitaro, Gianfranco ;
Malacrida, Maurizio ;
Boriani, Giuseppe ;
Biffi, Mauro .
CLINICAL CARDIOLOGY, 2015, 38 (10) :577-584
[5]   Clinically Significant Pocket Hematoma Increases Long-Term Risk of Device Infection BRUISE CONTROL INFECTION Study [J].
Essebag, Vidal ;
Verma, Atul ;
Healey, Jeff S. ;
Krahn, Andrew D. ;
Kalfon, Eli ;
Coutu, Benoit ;
Ayala-Paredes, Felix ;
Tang, Anthony S. ;
Sapp, John ;
Sturmer, Marcio ;
Keren, Arieh ;
Wells, George A. ;
Birnie, David H. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (11) :1300-1308
[6]   The Role of Prophylaxis Topical Antibiotics in Cardiac Device Implantation [J].
Khalighi, Koroush ;
Aung, Thein Tun ;
Elmi, Farhad .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2014, 37 (03) :304-311
[7]   Complications after cardiac implantable electronic device implantations: an analysis of a complete, nationwide cohort in Denmark [J].
Kirkfeldt, Rikke Esberg ;
Johansen, Jens Brock ;
Nohr, Ellen Aagaard ;
Jorgensen, Ole Dan ;
Nielsen, Jens Cosedis .
EUROPEAN HEART JOURNAL, 2014, 35 (18) :1186-1194
[8]   Prevalence of bacterial colonization of generator pockets in implantable cardioverter defibrillator patients without signs of infection undergoing generator replacement or lead revision [J].
Kleemann, Thomas ;
Becker, Torsten ;
Strauss, Margit ;
Dyck, Ngoc ;
Weisse, Udo ;
Saggau, Werner ;
Burkhardt, Ulrich ;
Seidl, Karlheinz .
EUROPACE, 2010, 12 (01) :58-63
[9]   Risk factors related to infections of implanted pacemakers and cardioverter-defibrillators - Results of a large prospective study [J].
Klug, Didier ;
Balde, Mamadou ;
Pavin, Dominique ;
Hidden-Lucet, Francoise ;
Clementy, Jacques ;
Sadoul, Nicolas ;
Rey, Jean Luc ;
Lande, Gilles ;
Lazarus, Arnaud ;
Victor, Jacques ;
Barnay, Claude ;
Grandbastien, Bruno ;
Kacet, Salem .
CIRCULATION, 2007, 116 (12) :1349-1355
[10]   Time for a Change - A New Approach to ICD Replacement [J].
Kramer, Daniel B. ;
Buxton, Alfred E. ;
Zimetbaum, Peter J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2012, 366 (04) :291-293