In vivo bone engineering in a rabbit femur

被引:41
作者
Fialkov, JA
Holy, CE
Shoichet, MS
Davies, JE
机构
[1] Sunnybrook & Womens Coll Hlth Sci Ctr, Dept Surg, Div Plast Surg, Toronto, ON M4N 3M5, Canada
[2] Univ Toronto, Inst Biomat & Biomed Engn, Toronto, ON, Canada
[3] Univ Toronto, Fac Appl Sci & Engn, Dept Chem Engn & Appl Chem, Toronto, ON, Canada
[4] Univ Toronto, Fac Dent, Toronto, ON, Canada
关键词
tissue engineering; PLGA scaffold; marrow cells; bone; critical sized defect; rabbit femur; bone formation index;
D O I
10.1097/00001665-200305000-00010
中图分类号
R61 [外科手术学];
学科分类号
摘要
The repair of bone defects in reconstructive surgery has significant limitations. Donor site morbidity, limited supply of autograft, and risks and complications associated with allografting and synthetic bone substitutes are among the most significant. In an effort to address these problems, the search for an ideal bone replacement has led to the development of a new method of poly(lactide-co-glycolide) (PLGA) foam processing, enabling the production of a biodegradable scaffold with similar porosity to human trabecular bone. In this study, these scaffolds were evaluated for bone repair in vivo in a femoral critical-sized segmental defect in New Zealand White (NZW) rabbits. Three groups of nine animals were investigated. In the first group, the critical-sized defects were empty. Scaffolds alone were implanted in the second group, whereas autologous bone marrow cell-loaded scaffolds were implanted in the third group. Animals ambulated freely for 8 weeks after surgery, and bone formation throughout the defects was serially assessed radiographically and quantified using a bone formation index (BFI) measure. Postmortem radiography and histology were also undertaken to examine bone formation. There was a significant effect of applying this technology to the amount of bone formed in the defects as determined by the BFI (F = 3.41, P < 0.05). The mean BFI for the cell-loaded scaffolds was greater than for the control group at all measured time points (2-, 4-, 6-, and 8-week radiographs). This difference was significant for the 2- and 8-week radiographs (P < 0.05). Qualitative histological assessment confirmed these findings. We concluded from these findings that these PLGA scaffolds loaded with marrow-derived progenitor cells yield significant bone formation in a critical-sized rabbit femoral defect. This technology comprising a novel scaffold design and autologous cells may provide an alternative to current strategies for reconstruction of bony defects.
引用
收藏
页码:324 / 332
页数:9
相关论文
共 37 条
  • [1] ATHANASIOU KA, 2000, BIOMATERIALS S, V21
  • [2] Three-dimensional matrices of calcium polyphosphates support bone growth in vitro and in vivo
    Baksh, D
    Davies, JE
    Kim, S
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1998, 9 (12) : 743 - 748
  • [3] BAKSH D, 2000, BONE ENG, P488
  • [4] Bone regeneration by implantation of purified, culture-expanded human mesenchymal stem cells
    Bruder, SP
    Kurth, AA
    Shea, M
    Hayes, WC
    Jaiswal, N
    Kadiyala, S
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1998, 16 (02) : 155 - 162
  • [5] Bruder SP, 1999, CLIN ORTHOP RELAT R, pS68
  • [6] Bone induction using demineralized bone in the rabbit femur: A long-term study
    Concannon, MJ
    Boschert, MT
    Puckett, CL
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 1997, 99 (07) : 1983 - 1988
  • [7] Davies J. E., 2000, BONE ENG
  • [8] DAVIES JE, 1991, CELL MATER, V1, P3
  • [9] Davies JE, 1996, ANAT REC, V245, P426
  • [10] Devies J.E., 2002, METHODS TISSUE ENG, P333