Laser-induced fluorescence of seeded nitric oxide as a flame thermometer

被引:44
作者
Tamura, M [1 ]
Luque, J
Harrington, JE
Berg, PA
Smith, GP
Jeffries, JB
Crosley, DR
机构
[1] SRI Int, Mol Phys Lab, Menlo Park, CA 94025 USA
[2] Tokyo Gas Co Ltd, Tokyo, Japan
来源
APPLIED PHYSICS B-LASERS AND OPTICS | 1998年 / 66卷 / 04期
关键词
D O I
10.1007/s003400050425
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Gas temperatures deduced from one-line and two-line laser-induced fluorescence (LIF) measurements of NO seeded into low-pressure methane flames are compared with those determined from LIF measurements of OH rotational distribution. The purpose is to make a quantitative assessment of the accuracy of one-and two-line LIF temperature strategies. Temperature determination from NO LIF intensity from a single transition must accurately account for any variation in the mole fraction of seeded NO. In the hot post-flame region. this added NO is diluted by the thermal equilibrium of radical species and incomplete combustion; this dilution depends on gas temperature and fuel/air stoichiometry. Chemical reactions of the NO produce an even larger variation in the NO mole fraction. Reburning of NO in the flame front (via reaction with CH) reduces the added NO by as much as 16% in the burnt gases of a slightly fuel-rich (Phi = 1.07) methane/air flame. The size of the reduction depends on both the amount of NO addition and the fuel/air stoichiometry. This effect can alter the apparent temperature determined from one-line NO LIF by as much as 25%. Two-line LIF strategies for gas temperature avoid these complications. Temperatures determined from all three LIF methods show good agreement in low-pressure flames, when a detailed model of the chemistry is used to correct the one-line NO temperature. However, in reactive systems where a modal of the chemistry cannot be applied, one-line LIF strategies for gas temperature from seeded NO are not reliable.
引用
收藏
页码:503 / 510
页数:8
相关论文
共 33 条
[21]  
MCMILLIN BK, 1994, AIAA J, V32, P4000
[22]   2-DIMENSIONAL LIF APPROACHES FOR THE ACCURATE DETERMINATION OF RADICAL CONCENTRATIONS AND TEMPERATURE IN COMBUSTION [J].
MEIER, U ;
KIENLE, R ;
PLATH, I ;
KOHSEHOINGHAUS, K .
BERICHTE DER BUNSEN-GESELLSCHAFT-PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 1992, 96 (10) :1401-1410
[23]  
MEYERSON AL, 1957, 6 S INT COMB COMB I, P154
[24]   MECHANISM AND MODELING OF NITROGEN CHEMISTRY IN COMBUSTION [J].
MILLER, JA ;
BOWMAN, CT .
PROGRESS IN ENERGY AND COMBUSTION SCIENCE, 1989, 15 (04) :287-338
[25]   COLLISIONAL QUENCHING CORRECTIONS FOR LASER-INDUCED FLUORESCENCE MEASUREMENTS OF NO A2-SIGMA+ [J].
PAUL, PH ;
GRAY, JA ;
DURANT, JL ;
THOMAN, JW .
AIAA JOURNAL, 1994, 32 (08) :1670-1675
[26]   A MODEL FOR TEMPERATURE-DEPENDENT COLLISIONAL QUENCHING OF NO A(2)SIGMA+ [J].
PAUL, PH ;
GRAY, JA ;
DURANT, JL ;
THOMAN, JW .
APPLIED PHYSICS B-PHOTOPHYSICS AND LASER CHEMISTRY, 1993, 57 (04) :249-259
[27]   Collisional electronic quenching rates for NO A(2)Sigma(+)(upsilon'=0) [J].
Paul, PH ;
Gray, JA ;
Durant, JL ;
Thoman, JW .
CHEMICAL PHYSICS LETTERS, 1996, 259 (5-6) :508-514
[28]   LASER-INDUCED FLUORESCENCE DETERMINATION OF TEMPERATURES IN LOW-PRESSURE FLAMES [J].
RENSBERGER, KJ ;
JEFFRIES, JB ;
COPELAND, RA ;
KOHSEHOINGHAUS, K ;
WISE, ML ;
CROSLEY, DR .
APPLIED OPTICS, 1989, 28 (17) :3556-3566
[29]   2-LINE PLANAR FLUORESCENCE FOR TEMPORALLY RESOLVED TEMPERATURE IMAGING IN A REACTING SUPERSONIC-FLOW OVER A BODY [J].
SEITZMAN, JM ;
HANSON, RK .
APPLIED PHYSICS B-PHOTOPHYSICS AND LASER CHEMISTRY, 1993, 57 (06) :385-391
[30]   INSTANTANEOUS TEMPERATURE-FIELD MEASUREMENTS USING PLANAR LASER-INDUCED FLUORESCENCE [J].
SEITZMAN, JM ;
KYCHAKOFF, G ;
HANSON, RK .
OPTICS LETTERS, 1985, 10 (09) :439-441