First Validation of Myocardial Flow Reserve Derived from Dynamic 99mTc-Sestamibi CZT-SPECT Camera Compared with 13N-Ammonia PET A Pilot Study

被引:10
作者
Yamamoto, Atsushi [1 ,2 ]
Nagao, Michinobu [2 ]
Ando, Kiyoe [1 ]
Nakao, Risako [1 ]
Matsuo, Yuka [2 ]
Sakai, Akiko [1 ]
Momose, Mitsuru [2 ]
Kaneko, Koichiro [2 ]
Hagiwara, Nobuhisa [1 ]
Sakai, Shuji [2 ]
机构
[1] Tokyo Womens Med Univ, Dept Cardiol, Tokyo, Japan
[2] Tokyo Womens Med Univ, Dept Imaging Diag & Nucl Med, Tokyo, Japan
关键词
Myocardial blood flow; Quantification; PERFUSION RESERVE; BLOOD-FLOW; DISEASE; QUANTIFICATION;
D O I
10.1536/ihj.21-487
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
N-13-ammonia positron emission tomography (NH3-PET) can evaluate myocardial blood flow (MBF) at rest, stress, and myocardial flow reserve (MFR) as well as the ratio of MBF at stress to that at rest. MFR is useful in predicting the prognoses of patients with various heart diseases. Cadmium-zinc-telluride single photon emission computed tomography (CZT-SPECT) enables us to acquire dynamic images of radiotracer kinetics and measure original MBF and MFR using Tc-99m-sestamibi. This study aimed to investigate the utility of CZT-SPECT for quantitative assessment of MBF compared to NH3-PET. We validated the correlation of MBF and MFR between CZT-SPECT and NH3-PET. Fourteen patients using one-day rest/stress CZT-SPECT, D-SPECT followed by NH3-PET within 1 month were enrolled and analyzed prospectively. The reproducibility of the MBF and MFR obtained with these two methods was examined using Spearman's correlation coefficient and Bland-Altman plot analysis. The diagnostic value of D-SPECT for abnormal MFR defined using NH3-PET results as MFR < 2.0 was assessed using receiver-operating characteristic (ROC) analysis. The median duration between D-SPECT and NH3-PET was 20 days. Although MBF was overestimated by D-SPECT compared to NH3-PET at high value (mean difference, 0.43 [0.34-0.53]), MBF and MFR were correlated with the two modalities (MBF: r = 0.71, P < 0.0001, MFR: r = 0.60, P < 0.0001). The ROC curve analysis demonstrated a cutoff of 1.6 for detecting abnormal MFR with D-SPECT (sensitivity, 68%; specificity, 91%; AUC, 0.75). MBF and MFR obtained using D-SPECT and NH3-PET had a good correlation, suggesting that the quantitative MFR evaluation by CZT-SPECT may help understand the trend of NH3-PET MFR.
引用
收藏
页码:202 / 209
页数:8
相关论文
共 29 条
  • [1] Quantification of myocardial perfusion reserve by CZT-SPECT: A head to head comparison with 82Rubidium PET imaging
    Acampa, Wanda
    Zampella, Emilia
    Assante, Roberta
    Genova, Andrea
    De Simini, Giovanni
    Mannarino, Teresa
    D'Antonio, Adriana
    Gaudieri, Valeria
    Nappi, Carmela
    Buongiorno, Pietro
    Mainolfi, Ciro Gabriele
    Petretta, Mario
    Cuocolo, Alberto
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2021, 28 (06) : 2827 - 2839
  • [2] Low-dose dynamic myocardial perfusion imaging by CZT-SPECT in the identification of obstructive coronary artery disease
    Acampa, Wanda
    Assante, Roberta
    Mannarino, Teresa
    Zampella, Emilia
    D'Antonio, Adriana
    Buongiorno, Pietro
    Gaudieri, Valeria
    Nappi, Carmela
    Giordano, Alessia
    Mainolfi, Ciro Gabriele
    Petretta, Mario
    Cuocolo, Alberto
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (07) : 1705 - 1712
  • [3] First validation of myocardial flow reserve assessed by dynamic 99mTc-sestamibi CZT-SPECT camera: head to head comparison with 15O-water PET and fractional flow reserve in patients with suspected coronary artery disease. The WATERDAY study
    Agostini, Denis
    Roule, Vincent
    Nganoa, Catherine
    Roth, Nathaniel
    Baavour, Raphael
    Parienti, Jean-Jacques
    Beygui, Farzin
    Manrique, Alain
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 (07) : 1079 - 1090
  • [4] Added Value of Myocardial Blood Flow Quantification and Calcium Scoring During CZT SPECT Myocardial Perfusion Imaging for Coronary Artery Disease Screening
    Bailly, Matthieu
    Thibault, Frederique
    Courtehoux, Maxime
    Metrard, Gilles
    Ribeiro, Maria-Joao
    [J]. CLINICAL NUCLEAR MEDICINE, 2019, 44 (11) : E617 - E619
  • [5] First determination of the heart-to-mediastinum ratio using cardiac dual isotope (123I-MIBG/99mTc-tetrofosmin) CZT imaging in patients with heart failure: the ADRECARD study
    Bellevre, Dimitri
    Manrique, Alain
    Legallois, Damien
    Bross, Samy
    Baavour, Rafael
    Roth, Nathaniel
    Blaire, Tanguy
    Desmonts, Cedric
    Bailliez, Alban
    Agostini, Denis
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 (12) : 1912 - 1919
  • [6] SPECT Myocardial Perfusion Reserve in Patients with Multivessel Coronary Disease: Correlation with Angiographic Findings and Invasive Fractional Flow Reserve Measurements
    Ben Bouallegue, Faycal
    Roubille, Francois
    Lattuca, Benoit
    Cung, Thien Tri
    Macia, Jean-Christophe
    Gervasoni, Richard
    Leclercq, Florence
    Mariano-Goulart, Denis
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (11) : 1712 - 1717
  • [7] Quantification of Myocardial Perfusion Reserve Using Dynamic SPECT Imaging in Humans: A Feasibility Study
    Ben-Haim, Simona
    Murthy, Venkatesh L.
    Breault, Christopher
    Allie, Rayjanah
    Sitek, Arkadiusz
    Roth, Nathaniel
    Fantony, Jolene
    Moore, Stephen C.
    Park, Mi-Ae
    Kijewski, Marie
    Haroon, Athar
    Slomka, Piotr
    Erlandsson, Kjell
    Baavour, Rafael
    Zilberstien, Yoel
    Bomanji, Jamshed
    Di Carli, Marcelo F.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2013, 54 (06) : 873 - 879
  • [8] Quantification of myocardial flow reserve using a gamma camera with solid-state cadmium-zinc-telluride detectors: Relation to angiographic coronary artery disease
    de Souza, Ana Carolina do A. H.
    Goncalves, Bernardo K. D.
    Tedeschi, Angelo L.
    Lima, Ronaldo S. L.
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2021, 28 (03) : 876 - 884
  • [9] Diagnostic Value of 13N-Ammonia Myocardial Perfusion PET: Added Value of Myocardial Flow Reserve
    Fiechter, Michael
    Ghadri, Jelena R.
    Gebhard, Catherine
    Fuchs, Tobias A.
    Pazhenkottil, Aju P.
    Nkoulou, Rene N.
    Herzog, Bernhard A.
    Wyss, Christophe A.
    Gaemperli, Oliver
    Kaufmann, Philipp A.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (08) : 1230 - 1234
  • [10] Comparison between N13NH3-PET and99mTc-Tetrofosmin-CZT SPECT in the evaluation of absolute myocardial blood flow and flow reserve
    Giubbini, Raffaele
    Bertoli, Mattia
    Durmo, Rexhep
    Bonacina, Mattia
    Peli, Alessia
    Faggiano, Ilio
    Albano, Domenico
    Milan, Elisa
    Stern, Eli
    Paghera, Barbara
    Rodella, Carlo
    Cerudelli, Elisabetta
    Gazzilli, Marina
    Dondi, Francesco
    Bertagna, Francesco
    Camoni, Luca
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2021, 28 (05) : 1906 - 1918