Dual-source CT coronary angiography without heart rate or rhythm control in comparison with conventional coronary angiography

被引:19
作者
Fang, Xiang Ming [1 ]
Chen, Hong Wei [1 ]
Hu, Xiao Yun [1 ]
Bao, Jian [1 ]
Chen, Yin [1 ]
Yang, Zhen Yu [2 ]
Buckley, Orla [3 ]
Wu, Xiao Qing [2 ]
机构
[1] Nanjing Med Univ, Wuxi Peoples Hosp, Dept Radiol, Wuxi City 214023, Jiangsu, Peoples R China
[2] Nanjing Med Univ, Wuxi Peoples Hosp, Dept Cardiol, Wuxi City 214023, Jiangsu, Peoples R China
[3] Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
关键词
Dual-source computed tomography; Angiography; Coronary artery disease; SPIRAL COMPUTED-TOMOGRAPHY; IMAGE QUALITY; RATE-VARIABILITY; ARTERY STENOSES; 1ST EXPERIENCE; SINGLE-SOURCE; ACCURACY; RESOLUTION; RECONSTRUCTION; DISEASE;
D O I
10.1007/s10554-009-9527-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To explore the value of dual-source CT angiography (DSCTA) in diagnosing coronary artery stenosis (CAS) without heart rate or rhythm control. Eighty-nine patients with different heart rates/rhythms underwent both DSCTA and conventional coronary angiography (CCA) in 1 week. The diagnostic quality of normal coronary arteries and stenosed segments using DSCTA and CCA were analyzed, respectively, with CCA as the gold standard. Kappa test was used to assess the intermodality agreement between DSCTA and CCA in grading CAS. The value of DSCTA in diagnosing CAS (> 50% stenoses) were analyzed as well. The total evaluable rate of DSCTA in detecting coronary arteries was 98.8%. No significant difference between evaluable rates from different groups of heart rate (chi (2) = 1.745, P > 0.05) was found. Sensitivity, specificity, positive and negative predictive values of DSCTA in detecting CAS and > 50% stenoses were 97.9, 96.8, 89.5, 99.4 and 97.2, 95.5, 80.3, 99.4%, respectively; The inter-modality agreement between DSCTA and CCA in grading CAS was found to be excellent (k = 0.856, P < 0.01). DSCTA provides high accuracy and reliability for evaluation of CAS in a high suspected patient group without heart rate/rhythm control. It can be used as a powerful primary tool for the detection of CAS and a potential substitute of CCA.
引用
收藏
页码:323 / 331
页数:9
相关论文
共 50 条
[21]   Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control [J].
Scheffel, Hans ;
Alkadhi, Hatem ;
Plass, Andre ;
Vachenauer, Robert ;
Desbiolles, Lotus ;
Gaemperli, Oliver ;
Schepis, Tiziano ;
Frauenfelder, Thomas ;
Schertler, Thomas ;
Husmann, Lars ;
Grunenfelder, Juerg ;
Genoni, Michele ;
Kaufmann, Philipp A. ;
Marincek, Borut ;
Leschka, Sebastian .
EUROPEAN RADIOLOGY, 2006, 16 (12) :2739-2747
[22]   Diagnostic accuracy of dual-source CT coronary angiography with prospective ECG-triggering on different heart rate patients [J].
Ming-li Sun ;
Bin Lu ;
Run-ze Wu ;
Laura Johnson ;
Lei Han ;
Gang Liu ;
Fang-Fang Yu ;
Zhi-hui Hou ;
Yang Gao ;
Hong-yu Wang ;
Shiliang Jiang ;
Yue-jin Yang ;
Shu-bin Qiao .
European Radiology, 2011, 21 :1635-1642
[23]   Characterization of culprit lesions in acute coronary syndromes using coronary dual-source CT angiography [J].
Pflederer, Tobias ;
Marwan, Mohamed ;
Schepis, Tiziano ;
Ropers, Dieter ;
Seltmann, Martin ;
Muschiol, Gerd ;
Daniel, Werner G. ;
Achenbach, Stephan .
ATHEROSCLEROSIS, 2010, 211 (02) :437-444
[24]   Influence of heart rate and phase of the cardiac cycle on the occurrence of motion artifact in dual-source CT angiography of the coronary arteries [J].
Achenbach, Stephan ;
Manolopoulos, Michael ;
Schuhbaeck, Annika ;
Ropers, Dieter ;
Rixe, Johannes ;
Schneider, Christian ;
Krombach, Gabriele A. ;
Uder, Michael ;
Hamm, Christian ;
Daniel, Werner G. ;
Lell, Michael .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (02) :91-98
[25]   Diagnostic accuracy of dual-source CT coronary angiography: The effect of average heart rate, heart rate variability, and calcium score in a clinical perspective [J].
Zhang, Long-Jiang ;
Wu, Sheng-Yong ;
Wang, Jing ;
Lu, Ying ;
Zhang, Zhuo-Li ;
Jiang, Shi-Sen ;
Zhou, Chang-Sheng ;
Lu, Guang-Ming .
ACTA RADIOLOGICA, 2010, 51 (07) :727-740
[26]   Robustness of end-systolic reconstructions in coronary dual-source CT angiography for high heart rate patients [J].
Adler, Ghazal ;
Meille, Laurent ;
Rohnean, Adela ;
Sigal-Cinqualbre, Anne ;
Capderou, Andre ;
Paul, Jean-Francois .
EUROPEAN RADIOLOGY, 2010, 20 (05) :1118-1123
[27]   Optimal image reconstruction phase at low and high heart rates in dual-source CT coronary angiography [J].
Araoz, Philip A. ;
Kirsch, Jacobo ;
Primak, Andrew N. ;
Braun, Natalie N. ;
Saba, Osama ;
Williamson, Eric E. ;
Harmsen, W. Scott ;
Mandrekar, Jayawant N. ;
McCollough, Cynthia H. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 (08) :837-845
[28]   Diagnostic accuracy of dual-source CT angiography and coronary risk stratification [J].
Yang, Xia ;
Gai, Lu-yue ;
Li, Ping ;
Chen, Yun-dai ;
Li, Tao ;
Yang, Li .
VASCULAR HEALTH AND RISK MANAGEMENT, 2010, 6 :935-941
[29]   Application of Dual-Source CT Coronary Angiography in Type 2 Diabetic Patients with Symptomatic Coronary Heart Disease [J].
He, Ci ;
Wang, Peng ;
Du, Fei-Zhou ;
Yang, Zhi-Gang .
CURRENT VASCULAR PHARMACOLOGY, 2017, 15 (01) :59-65
[30]   Incidence of anomalous origin of coronary artery in 1879 Chinese adults on dual-source CT angiography [J].
Zhang, L. J. ;
Yang, G. F. ;
Huang, W. ;
Zhou, C. S. ;
Chen, P. ;
Lu, G. M. .
NETHERLANDS HEART JOURNAL, 2010, 18 (10) :466-470