Dual-source CT coronary angiography without heart rate or rhythm control in comparison with conventional coronary angiography

被引:20
作者
Fang, Xiang Ming [1 ]
Chen, Hong Wei [1 ]
Hu, Xiao Yun [1 ]
Bao, Jian [1 ]
Chen, Yin [1 ]
Yang, Zhen Yu [2 ]
Buckley, Orla [3 ]
Wu, Xiao Qing [2 ]
机构
[1] Nanjing Med Univ, Wuxi Peoples Hosp, Dept Radiol, Wuxi City 214023, Jiangsu, Peoples R China
[2] Nanjing Med Univ, Wuxi Peoples Hosp, Dept Cardiol, Wuxi City 214023, Jiangsu, Peoples R China
[3] Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
关键词
Dual-source computed tomography; Angiography; Coronary artery disease; SPIRAL COMPUTED-TOMOGRAPHY; IMAGE QUALITY; RATE-VARIABILITY; ARTERY STENOSES; 1ST EXPERIENCE; SINGLE-SOURCE; ACCURACY; RESOLUTION; RECONSTRUCTION; DISEASE;
D O I
10.1007/s10554-009-9527-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To explore the value of dual-source CT angiography (DSCTA) in diagnosing coronary artery stenosis (CAS) without heart rate or rhythm control. Eighty-nine patients with different heart rates/rhythms underwent both DSCTA and conventional coronary angiography (CCA) in 1 week. The diagnostic quality of normal coronary arteries and stenosed segments using DSCTA and CCA were analyzed, respectively, with CCA as the gold standard. Kappa test was used to assess the intermodality agreement between DSCTA and CCA in grading CAS. The value of DSCTA in diagnosing CAS (> 50% stenoses) were analyzed as well. The total evaluable rate of DSCTA in detecting coronary arteries was 98.8%. No significant difference between evaluable rates from different groups of heart rate (chi (2) = 1.745, P > 0.05) was found. Sensitivity, specificity, positive and negative predictive values of DSCTA in detecting CAS and > 50% stenoses were 97.9, 96.8, 89.5, 99.4 and 97.2, 95.5, 80.3, 99.4%, respectively; The inter-modality agreement between DSCTA and CCA in grading CAS was found to be excellent (k = 0.856, P < 0.01). DSCTA provides high accuracy and reliability for evaluation of CAS in a high suspected patient group without heart rate/rhythm control. It can be used as a powerful primary tool for the detection of CAS and a potential substitute of CCA.
引用
收藏
页码:323 / 331
页数:9
相关论文
共 50 条
  • [21] Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control
    Scheffel, Hans
    Alkadhi, Hatem
    Plass, Andre
    Vachenauer, Robert
    Desbiolles, Lotus
    Gaemperli, Oliver
    Schepis, Tiziano
    Frauenfelder, Thomas
    Schertler, Thomas
    Husmann, Lars
    Grunenfelder, Juerg
    Genoni, Michele
    Kaufmann, Philipp A.
    Marincek, Borut
    Leschka, Sebastian
    EUROPEAN RADIOLOGY, 2006, 16 (12) : 2739 - 2747
  • [22] Characterization of culprit lesions in acute coronary syndromes using coronary dual-source CT angiography
    Pflederer, Tobias
    Marwan, Mohamed
    Schepis, Tiziano
    Ropers, Dieter
    Seltmann, Martin
    Muschiol, Gerd
    Daniel, Werner G.
    Achenbach, Stephan
    ATHEROSCLEROSIS, 2010, 211 (02) : 437 - 444
  • [23] Diagnostic accuracy of dual-source CT coronary angiography with prospective ECG-triggering on different heart rate patients
    Ming-li Sun
    Bin Lu
    Run-ze Wu
    Laura Johnson
    Lei Han
    Gang Liu
    Fang-Fang Yu
    Zhi-hui Hou
    Yang Gao
    Hong-yu Wang
    Shiliang Jiang
    Yue-jin Yang
    Shu-bin Qiao
    European Radiology, 2011, 21 : 1635 - 1642
  • [24] Influence of heart rate and phase of the cardiac cycle on the occurrence of motion artifact in dual-source CT angiography of the coronary arteries
    Achenbach, Stephan
    Manolopoulos, Michael
    Schuhbaeck, Annika
    Ropers, Dieter
    Rixe, Johannes
    Schneider, Christian
    Krombach, Gabriele A.
    Uder, Michael
    Hamm, Christian
    Daniel, Werner G.
    Lell, Michael
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (02) : 91 - 98
  • [25] Diagnostic accuracy of dual-source CT coronary angiography: The effect of average heart rate, heart rate variability, and calcium score in a clinical perspective
    Zhang, Long-Jiang
    Wu, Sheng-Yong
    Wang, Jing
    Lu, Ying
    Zhang, Zhuo-Li
    Jiang, Shi-Sen
    Zhou, Chang-Sheng
    Lu, Guang-Ming
    ACTA RADIOLOGICA, 2010, 51 (07) : 727 - 740
  • [26] Robustness of end-systolic reconstructions in coronary dual-source CT angiography for high heart rate patients
    Adler, Ghazal
    Meille, Laurent
    Rohnean, Adela
    Sigal-Cinqualbre, Anne
    Capderou, Andre
    Paul, Jean-Francois
    EUROPEAN RADIOLOGY, 2010, 20 (05) : 1118 - 1123
  • [27] Optimal image reconstruction phase at low and high heart rates in dual-source CT coronary angiography
    Araoz, Philip A.
    Kirsch, Jacobo
    Primak, Andrew N.
    Braun, Natalie N.
    Saba, Osama
    Williamson, Eric E.
    Harmsen, W. Scott
    Mandrekar, Jayawant N.
    McCollough, Cynthia H.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 (08) : 837 - 845
  • [28] Application of Dual-Source CT Coronary Angiography in Type 2 Diabetic Patients with Symptomatic Coronary Heart Disease
    He, Ci
    Wang, Peng
    Du, Fei-Zhou
    Yang, Zhi-Gang
    CURRENT VASCULAR PHARMACOLOGY, 2017, 15 (01) : 59 - 65
  • [29] Incidence of anomalous origin of coronary artery in 1879 Chinese adults on dual-source CT angiography
    Zhang, L. J.
    Yang, G. F.
    Huang, W.
    Zhou, C. S.
    Chen, P.
    Lu, G. M.
    NETHERLANDS HEART JOURNAL, 2010, 18 (10) : 466 - 470
  • [30] Diagnostic accuracy of dual-source CT angiography and coronary risk stratification
    Yang, Xia
    Gai, Lu-yue
    Li, Ping
    Chen, Yun-dai
    Li, Tao
    Yang, Li
    VASCULAR HEALTH AND RISK MANAGEMENT, 2010, 6 : 935 - 941