Dual-source CT coronary angiography without heart rate or rhythm control in comparison with conventional coronary angiography

被引:19
作者
Fang, Xiang Ming [1 ]
Chen, Hong Wei [1 ]
Hu, Xiao Yun [1 ]
Bao, Jian [1 ]
Chen, Yin [1 ]
Yang, Zhen Yu [2 ]
Buckley, Orla [3 ]
Wu, Xiao Qing [2 ]
机构
[1] Nanjing Med Univ, Wuxi Peoples Hosp, Dept Radiol, Wuxi City 214023, Jiangsu, Peoples R China
[2] Nanjing Med Univ, Wuxi Peoples Hosp, Dept Cardiol, Wuxi City 214023, Jiangsu, Peoples R China
[3] Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
关键词
Dual-source computed tomography; Angiography; Coronary artery disease; SPIRAL COMPUTED-TOMOGRAPHY; IMAGE QUALITY; RATE-VARIABILITY; ARTERY STENOSES; 1ST EXPERIENCE; SINGLE-SOURCE; ACCURACY; RESOLUTION; RECONSTRUCTION; DISEASE;
D O I
10.1007/s10554-009-9527-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To explore the value of dual-source CT angiography (DSCTA) in diagnosing coronary artery stenosis (CAS) without heart rate or rhythm control. Eighty-nine patients with different heart rates/rhythms underwent both DSCTA and conventional coronary angiography (CCA) in 1 week. The diagnostic quality of normal coronary arteries and stenosed segments using DSCTA and CCA were analyzed, respectively, with CCA as the gold standard. Kappa test was used to assess the intermodality agreement between DSCTA and CCA in grading CAS. The value of DSCTA in diagnosing CAS (> 50% stenoses) were analyzed as well. The total evaluable rate of DSCTA in detecting coronary arteries was 98.8%. No significant difference between evaluable rates from different groups of heart rate (chi (2) = 1.745, P > 0.05) was found. Sensitivity, specificity, positive and negative predictive values of DSCTA in detecting CAS and > 50% stenoses were 97.9, 96.8, 89.5, 99.4 and 97.2, 95.5, 80.3, 99.4%, respectively; The inter-modality agreement between DSCTA and CCA in grading CAS was found to be excellent (k = 0.856, P < 0.01). DSCTA provides high accuracy and reliability for evaluation of CAS in a high suspected patient group without heart rate/rhythm control. It can be used as a powerful primary tool for the detection of CAS and a potential substitute of CCA.
引用
收藏
页码:323 / 331
页数:9
相关论文
共 22 条
[1]  
Achenbach S, 2001, CIRCULATION, V103, P2535
[2]  
Austen W G, 1975, Circulation, V51, P5
[3]   American College of Cardiology/Society for Cardiac Angiography and Interventions clinical expert consensus document on Cardiac Catheterization Laboratory standards - A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents [J].
Bashore, TM ;
Bates, ER ;
Berger, PB ;
Clark, DA ;
Cusma, JT ;
Dehmer, GJ ;
Kern, MJ ;
Laskey, WK ;
O'Laughlin, MP ;
Oesterle, S ;
Popma, JJ ;
O'Rourke, RA ;
Abrams, J ;
Bates, ER ;
Brodie, BR ;
Douglas, PS ;
Gregoratos, G ;
Hlatky, MA ;
Hochman, JS ;
Kaul, S ;
Tracy, CM ;
Waters, DD ;
Winters, WL .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (08) :2170-2214
[4]  
BOLL DT, 2005, RADIOLOGY S, P9
[5]   Assessment of image quality of 64-row Dual Source versus Single Source CT coronary angiography on heart rate: A phantom study [J].
Dikkers, R. ;
Greuter, M. J. W. ;
Kristanto, W. ;
van Ooijen, P. M. A. ;
Sijens, P. E. ;
Willems, T. P. ;
Oudkerk, M. .
EUROPEAN JOURNAL OF RADIOLOGY, 2009, 70 (01) :61-68
[6]   Quantitative parameters of image quality in 64-slice computed tomography angiography of the coronary arteries [J].
Ferencik, M ;
Nomura, CH ;
Maurovich-Horvat, P ;
Hoffmann, U ;
Pena, AJ ;
Cury, RC ;
Abbara, S ;
Nieman, K ;
Fatima, U ;
Achenbach, S ;
Brady, TJ .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 57 (03) :373-379
[7]   Diagnostic accuracy of dual-source computed tomography in the diagnosis of coronary artery disease [J].
Johnson, Thorsten R. C. ;
Nikolaou, Konstantin ;
Busch, Stephanie ;
Leber, Alexander W. ;
Becker, Alexander ;
Wintersperger, Bernd J. ;
Rist, Carsten ;
Knez, Andreas ;
Reiser, Maximilian F. ;
Becker, Christoph R. .
INVESTIGATIVE RADIOLOGY, 2007, 42 (10) :684-691
[8]   Dual-source CT cardiac imaging: initial experience [J].
Johnson, Thorsten R. C. ;
Nikolaou, Konstantin ;
Wintersperger, Bernd J. ;
Leber, Alexander W. ;
von Ziegler, Franz ;
Rist, Carsten ;
Buhmann, Sonja ;
Knez, Andreas ;
Reiser, Maximilian F. ;
Becker, Christoph R. .
EUROPEAN RADIOLOGY, 2006, 16 (07) :1409-1415
[9]   Non-invasive coronary angiography with high resolution multidetector-row computed tomography - Results in 102 patients [J].
Kopp, AF ;
Schroeder, S ;
Kuettner, A ;
Baumbach, A ;
Georg, C ;
Kuzo, R ;
Heuschmid, M ;
Ohnesorge, B ;
Karsch, KR ;
Claussen, CD .
EUROPEAN HEART JOURNAL, 2002, 23 (21) :1714-1725
[10]   Accuracy of MSCT coronary angiography with 64-slice technology:: first experience [J].
Leschka, S ;
Alkadhi, H ;
Plass, A ;
Desbiolles, L ;
Grünenfelder, J ;
Marincek, B ;
Wildermuth, S .
EUROPEAN HEART JOURNAL, 2005, 26 (15) :1482-1487