Improved 3-Tesla Cardiac Cine Imaging Using Wideband

被引:7
作者
Lee, Hsu-Lei [1 ]
Shankaranarayanan, Ajit [2 ]
Pohost, Gerald M. [3 ]
Nayak, Krishna S. [1 ,3 ]
机构
[1] Univ So Calif, Ming Hsieh Dept Elect Engn, Magnet Resonance Engn Lab, Los Angeles, CA USA
[2] GE Healthcare, Global Appl Sci Lab, Menlo Pk, CA USA
[3] Univ So Calif, Keck Sch Med, Los Angeles, CA 90033 USA
基金
美国国家卫生研究院;
关键词
cardiac ventricular function; balanced SSFP; wideband SSFP; alternating repetition; cine imaging; STATE FREE PRECESSION; TRUE-FISP; TESLA; SSFP;
D O I
10.1002/mrm.22384
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Cine balanced steady-state free precession (SSFP) is the most widely used sequence for assessing cardiac ventricular function at 1.5 T because it provides high signal-to-noise ratio efficiency and strong contrast between myocardium and blood. At 3 T, the use of SSFP is limited by susceptibility-induced off-resonance, resulting in either banding artifacts or the need to use a short-sequence pulse repetition time that limits the readout duration and hence the achievable spatial resolution. In this work, we apply wideband SSFP, a variant of SSFP that uses two alternating pulse repetition times to establish a steady state with wider band spacing in its frequency response and overcome the key limitations of SSFP. Prospectively gated cine two-dimensional imaging with wideband SSFP is evaluated in healthy volunteers and compared to conventional balanced SSFP, using quantitative metrics and qualitative interpretation by experienced clinicians. We demonstrate that by trading off temporal resolution and signal-to-noise ratio efficiency, wideband SSFP mitigates banding artifacts and enables imaging with approximately 30% higher spatial resolution compared to conventional SSFP with the same effective band spacing. Magn Reson Med 63:1716-1722, 2010. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:1716 / 1722
页数:7
相关论文
共 22 条
  • [1] VARIABLE-RATE SELECTIVE EXCITATION
    CONOLLY, S
    NISHIMURA, D
    MACOVSKI, A
    GLOVER, G
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1988, 78 (03): : 440 - 458
  • [2] CARDIAC EJECTION FRACTION - PHANTOM STUDY COMPARING CINE MR IMAGING, RADIONUCLIDE BLOOD POOL IMAGING, AND VENTRICULOGRAPHY
    DEBATIN, JF
    NADEL, SN
    PAOLINI, JF
    SOSTMAN, HD
    COLEMAN, RE
    EVANS, AJ
    BEAM, C
    SPRITZER, CE
    BASHORE, TM
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (02): : 135 - 142
  • [3] Artifact reduction in true-FISP imaging of the coronary arteries by adjusting imaging frequency
    Deshpande, VS
    Shea, SM
    Li, DB
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (05) : 803 - 809
  • [4] Remember true FISP? A high SNR, near 1-second imaging method for T2-like contrast in interventional MRI at .2 T
    Duerk, JL
    Lewin, JS
    Wendt, M
    Petersilge, C
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01): : 203 - 208
  • [5] REPORT OF THE AMERICAN-SOCIETY-OF-ECHOCARDIOGRAPHY COMMITTEE-ON-NOMENCLATURE-AND-STANDARDS-IN-2-DIMENSIONAL-ECHOCARDIOGRAPHY
    HENRY, WL
    DEMARIA, A
    GRAMIAK, R
    KING, DL
    KISSLO, JA
    POPP, RL
    SAHN, DJ
    SCHILLER, NB
    TAJIK, A
    TEICHHOLZ, LE
    WEYMAN, AE
    [J]. CIRCULATION, 1980, 62 (02) : 212 - 217
  • [6] WHICH STANDARD HAS THE GOLD
    HIGGINS, CB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (07) : 1608 - 1609
  • [7] Lee H.L., 2006, P 14 ANN M ISMRM, P143
  • [8] LEE HL, 2009, P 17 ANN M ISMRM KYO, P768
  • [9] Lee HL, 2009, P 17 ANN M ISMRM HON, P4643
  • [10] Alternating repetition time balanced steady state free precession
    Leupold, J
    Hennig, J
    Scheffler, K
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (03) : 557 - 565