Efficacy of AccuVein to Facilitate Peripheral Intravenous Placement in Adults Presenting to an Emergency Department: A Randomized Clinical Trial

被引:42
作者
Aulagnier, Jerome [1 ]
Hoc, Cecile [1 ]
Mathieu, Emmanuel [1 ]
Dreyfus, Jean Francois [2 ]
Fischler, Marc [3 ,4 ]
Le Guen, Morgan [3 ,4 ]
机构
[1] Hop Foch, Emergency Dept, Suresnes, France
[2] Hop Foch, Dept Clin Res & Innovat, Suresnes, France
[3] Hop Foch, Dept Anesthesiol, Suresnes, France
[4] Univ Versailles St Quentin Yvelines, Versailles, France
关键词
INSERTION DIFFICULTY; CANNULATION; CHILDREN; ACCESS; TRANSILLUMINATION; TECHNOLOGY; INFANTS; DEVICE;
D O I
10.1111/acem.12437
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives In the emergency department (ED), intravenous (IV) catheter placement is one of the most frequent interventions and may be a real challenge in some conditions. Improvement of the success rate with new technology represents a great opportunity. This randomized controlled trial aimed to show the superiority of AccuVein to cannulate veins in adults compared to routine care. Methods After giving written consent, patients were randomized into two groups: routine IV catheter insertion or insertion guided by the AccuVein, which is a hand-held instrument displaying laser light to optimize visualization of veins. The primary outcome was the time to successful placement of catheters. Secondary outcomes included the number of attempts, the rate of failure, technique-related pain, occurrence of movements, and efficiency of IV cannulation as perceived by the operator when using the AccuVein device. Results are given as mean and bootstrapped 95% confidence interval (CI) and percentages. p-valuesof <0.05 were considered significant. Results A total of 266 six patients were included, with 157 randomized to routine cannulation and 115 to AccuVein. Patient characteristics were similar. Time to successful placement of IV catheter (routine, 98seconds, 95% CI=85 to 113seconds; and AccuVein, 119seconds, 95% CI=93 to 154seconds) was not different between groups (p=0.24). Secondary outcomes (failure and pain) did not significantly differ, except for movements, which were more frequent when using the AccuVein device (19.1% vs. 10.2%, p=0.05). Evaluation of the AccuVein by operators was more often negative than positive. Conclusions Use of the AccuVein did not improve IV cannulation in nonselected ED patients.
引用
收藏
页码:858 / 863
页数:6
相关论文
共 12 条
[1]   Vein Viewer-assisted Intravenous Catheter Placement in a Pediatric Emergency Department [J].
Chapman, Laura L. ;
Sullivan, Brenna ;
Pacheco, Amanda L. ;
Draleau, Charlene P. ;
Becker, Bruce M. .
ACADEMIC EMERGENCY MEDICINE, 2011, 18 (09) :966-971
[2]   Vein visualization: patient characteristic factors and efficacy of a new infrared vein finder technology [J].
Chiao, F. B. ;
Resta-Flarer, F. ;
Lesser, J. ;
Ng, J. ;
Ganz, A. ;
Pino-Luey, D. ;
Bennett, H. ;
Perkins, C., Jr. ;
Witek, B. .
BRITISH JOURNAL OF ANAESTHESIA, 2013, 110 (06) :966-971
[3]   Near-infrared light to aid peripheral intravenous cannulation in children: a cluster randomised clinical trial of three devices [J].
de Graaff, J. C. ;
Cuper, N. J. ;
Mungra, R. A. A. ;
Vlaardingerbroek, K. ;
Numan, S. C. ;
Kalkman, C. J. .
ANAESTHESIA, 2013, 68 (08) :835-845
[4]   Transillumination of the palm for venipuncture in infants [J].
Goren, A ;
Laufer, J ;
Yativ, N ;
Kuint, J ;
Ben Ackon, M ;
Rubinshtein, M ;
Paret, G ;
Augarten, A .
PEDIATRIC EMERGENCY CARE, 2001, 17 (02) :130-131
[5]   Ultrasound-guided peripheral intravenous access in the intensive care unit [J].
Gregg, Shea C. ;
Murthi, Sarah B. ;
Sisley, Amy C. ;
Stein, Deborah M. ;
Scalea, Thomas M. .
JOURNAL OF CRITICAL CARE, 2010, 25 (03) :514-519
[6]   Variables influencing intravenous catheter insertion difficulty and failure: An analysis of 339 intravenous catheter insertions [J].
Jacobson, AF ;
Winslow, EH .
HEART & LUNG, 2005, 34 (05) :345-359
[7]   Intradermal normal saline solution, self-selected music, and insertion difficulty effects on intravenous insertion pain [J].
Jacobson, AF .
HEART & LUNG, 1999, 28 (02) :114-122
[8]   Transillumination for vascular access: old concept, new technology [J].
John, Justin M. .
PEDIATRIC ANESTHESIA, 2007, 17 (02) :197-198
[9]   A randomized controlled trial comparing the AccuVein AV300 device to standard insertion technique for intravenous cannulation of anesthetized children [J].
Kaddoum, Roland N. ;
Anghelescu, Doralina L. ;
Parish, Mary E. ;
Wright, Becky B. ;
Trujillo, Luis ;
Wu, Jianrong ;
Wu, Yanan ;
Burgoyne, Laura L. .
PEDIATRIC ANESTHESIA, 2012, 22 (09) :884-889
[10]   Prospective evaluation of peripheral venous access difficulty in emergency care [J].
Lapostolle, Frederic ;
Catineau, Jean ;
Garrigue, Bruno ;
Monmarteau, Vincent ;
Houssaye, Thierry ;
Vecci, Isabelle ;
Treoux, Virginie ;
Hospital, Baptistine ;
Crocheton, Nicolas ;
Adnet, Frederic .
INTENSIVE CARE MEDICINE, 2007, 33 (08) :1452-1457