Meningiomas: A Comparative Study of 68Ga-DOTATOC, 68Ga-DOTANOC and 68Ga-DOTATATE for Molecular Imaging in Mice

被引:20
|
作者
Luisa Soto-Montenegro, Maria [1 ,2 ]
Pena-Zalbidea, Santiago [1 ]
Maria Mateos-Perez, Jose [1 ]
Oteo, Marta [4 ]
Romero, Eduardo [4 ]
Angel Morcillo, Miguel [4 ]
Desco, Manuel [1 ,3 ]
机构
[1] Inst Invest Sanitaria Gregorio Maranon, Unidad Med & Cirugi Expt, Madrid, Spain
[2] Ctr Invest Biomed Red Salud Mental CIBERSAM, Madrid, Spain
[3] Univ Carlos III Madrid, Dept Bioingn & Ingn Aerosp, Madrid, Spain
[4] Ctr Invest Energet Medioambientales & Tecnol CIEM, Unidad Aplicac Biomed & Farmacocinet, Madrid, Spain
来源
PLOS ONE | 2014年 / 9卷 / 11期
关键词
SOMATOSTATIN RECEPTOR SUBTYPE-2; TARGET VOLUME DEFINITION; NEUROENDOCRINE TUMORS; HIGH-AFFINITY; DOTA-NOC; PET/CT; EXPRESSION; MRI; BIODISTRIBUTION; RADIOMETALS;
D O I
10.1371/journal.pone.0111624
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose: The goal of this study was to compare the tumor uptake kinetics and diagnostic value of three Ga-68-DOTA-labeled somatostatin analogues (Ga-68-DOTATOC, Ga-68-DOTANOC, and Ga-68-DOTATATE) using PET/CT in a murine model with subcutaneous meningioma xenografts. Methods: The experiment was performed with 16 male NUDE NU/NU mice bearing xenografts of a human meningioma cell line (CH-157MN). Ga-68-DOTATOC, Ga-68-DOTANOC, and Ga-68-DOTATATE were produced in a FASTLab automated platform. Imaging was performed on an Argus small-animal PET/CT scanner. The SUVmax of the liver and muscle, and the tumor-to-liver (T/L) and tumor-to-muscle (T/M) SUV ratios were computed. Kinetic analysis was performed using Logan graphical analysis for a two-tissue reversible compartmental model, and the volume of distribution (V-t) was determined. Results: Hepatic SUVmax and V-t were significantly higher with Ga-68-DOTANOC than with Ga-68-DOTATOC and Ga-68-DOTATATE. No significant differences between tracers were found for SUVmax in tumor or muscle. No differences were found in the T/L SUV ratio between Ga-68-DOTATATE and Ga-68-DOTATOC, both of which had a higher fraction than Ga-68-DOTANOC. The T/M SUV ratio was significantly higher with Ga-68-DOTATATE than with Ga-68-DOTATOC and Ga-68-DOTANOC. The V-t for tumor was higher with Ga-68-DOTATATE than with Ga-68-DOTANOC and relatively similar to that of Ga-68-DOTATOC. Conclusions: This study demonstrates, for the first time, the ability of the three radiolabeled somatostatin analogues tested to image a human meningioma cell line. Although V-t was relatively similar with Ga-68-DOTATATE and Ga-68-DOTATOC, uptake was higher with Ga-68-DOTATATE in the tumor than with Ga-68-DOTANOC and Ga-68-DOTATOC, suggesting a higher diagnostic value of Ga-68-DOTATATE for detecting meningiomas.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Clinical applications of 68Ga-DOTANOC in neuroendocrine tumours
    Lopci, E.
    Nanni, C.
    Rampin, L.
    Rubello, D.
    Fanti, S.
    MINERVA ENDOCRINOLOGICA, 2008, 33 (03) : 277 - 281
  • [22] 68Ga-DOTATATE PET/CT Imaging in Carotid Body Tumor
    Gayana, Shankaramurthy
    Mittal, Bhagwant Rai
    Bhattacharya, Anish
    Radotra, Bishan Dass
    Gupta, Ashok K.
    CLINICAL NUCLEAR MEDICINE, 2013, 38 (04) : E191 - E193
  • [23] The pitfalls of 68Ga-DOTATATE Imaging. A case report
    D'Cruz, V. A.
    Libbrecht, S.
    Hoorens, A.
    De Man, K.
    van Ramshorst, G. H.
    Geboes, K. P.
    ACTA GASTRO-ENTEROLOGICA BELGICA, 2023, 86 (01) : 92 - 94
  • [24] Potential impact of 68Ga-DOTATOC PET/CT on stereotactic radiotherapy planning of meningiomas
    Fonyuy Nyuyki
    Michail Plotkin
    Reinhold Graf
    Roger Michel
    Ingo Steffen
    Timm Denecke
    Lilli Geworski
    Daniel Fahdt
    Winfried Brenner
    Reinhard Wurm
    European Journal of Nuclear Medicine and Molecular Imaging, 2010, 37 : 310 - 318
  • [25] Exceptional Visualization of the Gallbladder on 68Ga-DOTANOC PET/CT Imaging
    Solanki, Ritanshu
    Singh, Harmandeep
    Kumar, Rajender
    CLINICAL NUCLEAR MEDICINE, 2022, 47 (06) : E468 - E469
  • [26] Potential impact of 68Ga-DOTATOC PET/CT on stereotactic radiotherapy planning of meningiomas
    Nyuyki, Fonyuy
    Plotkin, Michail
    Graf, Reinhold
    Michel, Roger
    Steffen, Ingo
    Denecke, Timm
    Geworski, Lilli
    Fahdt, Daniel
    Brenner, Winfried
    Wurm, Reinhard
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (02) : 310 - 318
  • [27] Diagnostic accuracy of 68Ga-DOTANOC PET/CT imaging in pheochromocytoma
    Punit Sharma
    Varun Singh Dhull
    Saurabh Arora
    Poonam Gupta
    Rajeev Kumar
    Prashant Durgapal
    Arun Malhotra
    Sunil Chumber
    Ariachery C. Ammini
    Rakesh Kumar
    Chandrasekhar Bal
    European Journal of Nuclear Medicine and Molecular Imaging, 2014, 41 : 494 - 504
  • [28] Comparison of 68Ga-DOTATATE PET/CT and 68Ga-Pentixiafor PET/CT Imaging in a Case of Merkel Cell Carcinoma
    Rao, Zijuan
    Zhang, Yu
    Liu, Liyi
    Wang, Min
    Zhang, Chunyin
    CLINICAL NUCLEAR MEDICINE, 2023, 48 (04) : 339 - 341
  • [29] 68Ga-DOTATATE and 68Ga-Pentixafor PET/CT in a Patient with Castleman Disease of the Retroperitoneum
    Zuo, Rui
    Xu, Lu
    Pang, Hua
    DIAGNOSTICS, 2024, 14 (04)
  • [30] Evaluation of 68Ga-DOTATOC PET/MRI for whole-body staging of neuroendocrine tumours in comparison with 68Ga-DOTATOC PET/CT
    Lino M. Sawicki
    Cornelius Deuschl
    Karsten Beiderwellen
    Verena Ruhlmann
    Thorsten D. Poeppel
    Philipp Heusch
    Harald Lahner
    Dagmar Führer
    Andreas Bockisch
    Ken Herrmann
    Michael Forsting
    Gerald Antoch
    Lale Umutlu
    European Radiology, 2017, 27 : 4091 - 4099