Meningiomas: A Comparative Study of 68Ga-DOTATOC, 68Ga-DOTANOC and 68Ga-DOTATATE for Molecular Imaging in Mice

被引:20
|
作者
Luisa Soto-Montenegro, Maria [1 ,2 ]
Pena-Zalbidea, Santiago [1 ]
Maria Mateos-Perez, Jose [1 ]
Oteo, Marta [4 ]
Romero, Eduardo [4 ]
Angel Morcillo, Miguel [4 ]
Desco, Manuel [1 ,3 ]
机构
[1] Inst Invest Sanitaria Gregorio Maranon, Unidad Med & Cirugi Expt, Madrid, Spain
[2] Ctr Invest Biomed Red Salud Mental CIBERSAM, Madrid, Spain
[3] Univ Carlos III Madrid, Dept Bioingn & Ingn Aerosp, Madrid, Spain
[4] Ctr Invest Energet Medioambientales & Tecnol CIEM, Unidad Aplicac Biomed & Farmacocinet, Madrid, Spain
来源
PLOS ONE | 2014年 / 9卷 / 11期
关键词
SOMATOSTATIN RECEPTOR SUBTYPE-2; TARGET VOLUME DEFINITION; NEUROENDOCRINE TUMORS; HIGH-AFFINITY; DOTA-NOC; PET/CT; EXPRESSION; MRI; BIODISTRIBUTION; RADIOMETALS;
D O I
10.1371/journal.pone.0111624
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose: The goal of this study was to compare the tumor uptake kinetics and diagnostic value of three Ga-68-DOTA-labeled somatostatin analogues (Ga-68-DOTATOC, Ga-68-DOTANOC, and Ga-68-DOTATATE) using PET/CT in a murine model with subcutaneous meningioma xenografts. Methods: The experiment was performed with 16 male NUDE NU/NU mice bearing xenografts of a human meningioma cell line (CH-157MN). Ga-68-DOTATOC, Ga-68-DOTANOC, and Ga-68-DOTATATE were produced in a FASTLab automated platform. Imaging was performed on an Argus small-animal PET/CT scanner. The SUVmax of the liver and muscle, and the tumor-to-liver (T/L) and tumor-to-muscle (T/M) SUV ratios were computed. Kinetic analysis was performed using Logan graphical analysis for a two-tissue reversible compartmental model, and the volume of distribution (V-t) was determined. Results: Hepatic SUVmax and V-t were significantly higher with Ga-68-DOTANOC than with Ga-68-DOTATOC and Ga-68-DOTATATE. No significant differences between tracers were found for SUVmax in tumor or muscle. No differences were found in the T/L SUV ratio between Ga-68-DOTATATE and Ga-68-DOTATOC, both of which had a higher fraction than Ga-68-DOTANOC. The T/M SUV ratio was significantly higher with Ga-68-DOTATATE than with Ga-68-DOTATOC and Ga-68-DOTANOC. The V-t for tumor was higher with Ga-68-DOTATATE than with Ga-68-DOTANOC and relatively similar to that of Ga-68-DOTATOC. Conclusions: This study demonstrates, for the first time, the ability of the three radiolabeled somatostatin analogues tested to image a human meningioma cell line. Although V-t was relatively similar with Ga-68-DOTATATE and Ga-68-DOTATOC, uptake was higher with Ga-68-DOTATATE in the tumor than with Ga-68-DOTANOC and Ga-68-DOTATOC, suggesting a higher diagnostic value of Ga-68-DOTATATE for detecting meningiomas.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Comparative Biodistribution and Radiation Dosimetry of 68Ga-DOTATOC and 68Ga-DOTATATE in Patients with Neuroendocrine Tumors
    Sandstrom, Mattias
    Velikyan, Irina
    Garske-Roman, Ulrike
    Sorensen, Jens
    Eriksson, Barbro
    Granberg, Dan
    Lundqvist, Hans
    Sundin, Anders
    Lubberink, Mark
    JOURNAL OF NUCLEAR MEDICINE, 2013, 54 (10) : 1755 - 1759
  • [2] Comparison of 68Ga-DOTANOC and 68Ga-DOTATATE PET/CT Within Patients with Gastroenteropancreatic Neuroendocrine Tumors
    Wild, Damian
    Bomanji, Jamshed B.
    Benkert, Pascal
    Maecke, Helmut
    Ell, Peter J.
    Reubi, Jean Claude
    Caplin, Martyn E.
    JOURNAL OF NUCLEAR MEDICINE, 2013, 54 (03) : 364 - 372
  • [3] Comparison of 68Ga-DOTATATE and 68Ga-DOTANOC PET/CT imaging in the same patient group with neuroendocrine tumours
    Kabasakal, Levent
    Demirci, Emre
    Ocak, Meltem
    Decristoforo, Clemens
    Araman, Ahmet
    Ozsoy, Yildiz
    Uslu, Ilhami
    Kanmaz, Bedii
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 (08) : 1271 - 1277
  • [4] 68Ga-DOTATOC Versus 68Ga-DOTATATE PET/CT in Functional Imaging of Neuroendocrine Tumors
    Poeppel, Thorsten D.
    Binse, Ina
    Petersenn, Stephan
    Lahner, Harald
    Schott, Matthias
    Antoch, Gerald
    Brandau, Wolfgang
    Bockisch, Andreas
    Boy, Christian
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52 (12) : 1864 - 1870
  • [5] Quantitative and Qualitative Intrapatient Comparison of 68Ga-DOTATOC and 68Ga-DOTATATE: Net Uptake Rate for Accurate Quantification
    Velikyan, Irina
    Sundin, Anders
    Sorensen, Jens
    Lubberink, Mark
    Sandstrom, Mattias
    Garske-Roman, Ulrike
    Lundqvist, Hans
    Granberg, Dan
    Eriksson, Barbro
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (02) : 204 - 210
  • [6] Relevant Discordance Between 68Ga-DOTATATE and 68Ga-DOTANOC in SDHB-Related Metastatic Paraganglioma Is Affinity to Somatostatin Receptor 2 the Key?
    Janssen, Ingo
    Wolf, Katherine I.
    Chui, Chan H.
    Millo, Corina M.
    Pacak, Karel
    CLINICAL NUCLEAR MEDICINE, 2017, 42 (03) : 211 - 213
  • [7] Parametric Net Influx Rate Images of 68Ga-DOTATOC and 68Ga-DOTATATE: Quantitative Accuracy and Improved Image Contrast
    Ilan, Ezgi
    Sandstrom, Mattias
    Velikyan, Irina
    Sundin, Anders
    Eriksson, Barbro
    Lubberink, Mark
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58 (05) : 744 - 749
  • [8] Tumor-to-Blood Ratio for Assessment of Somatostatin Receptor Density in Neuroendocrine Tumors Using 68Ga-DOTATOC and 68Ga-DOTATATE
    Ilan, Ezgi
    Velikyan, Irina
    Sandstrom, Mattias
    Sundin, Anders
    Lubberink, Mark
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61 (02) : 217 - 221
  • [9] 68Ga-DOTATATE and 68Ga-FAPI Imaging in Neuroendocrine Neoplasms of Different Grades
    Zhou, Yue
    Ou, Lei
    Yu, Songke
    Deng, Hao
    Chen, Xiaoliang
    CLINICAL NUCLEAR MEDICINE, 2024, 49 (06) : 564 - 566
  • [10] Altered Biodistribution of 68Ga-DOTATOC
    Dupont, Anne-Claire
    Borrelly, Fanny
    Lecomte, Thierry
    Maia, Serge
    Santiago Ribeiro, Maria-Joao
    CLINICAL NUCLEAR MEDICINE, 2021, 46 (02) : 164 - 165