Direct electrochemistry of covalently immobilized hemoglobin on a naphthylimidazolium butyric acid ionic liquid/MWCNT matrix

被引:16
作者
Murphy, Manoharan [1 ]
Theyagarajan, K. [1 ]
Thenmozhi, Kathavarayan [1 ]
Senthilkumar, Sellappan [1 ]
机构
[1] Vellore Inst Technol VIT, Sch Adv Sci, Dept Chem, Vellore 632014, Tamil Nadu, India
关键词
Hydrogen peroxide; Ionic liquid; Hemoglobin; Direct electrochemistry; Biosensor;
D O I
10.1016/j.colsurfb.2020.111540
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Monitoring the concentration levels of hydrogen peroxide (H2O2) is significant in both clinical and industrial applications. Herein, we develop a facile biosensor for the detection of H2O2 based on direct electron transfer of hemoglobin (Hb), which was covalently immobilized on a hydrophobic naphthylimidazolium butyric acid ionic liquid (NIBA-IL) over a multiwalled carbon nanotube (MWCNT) modified glassy carbon electrode (GCE) to obtain an Hb/NIBA-IL/MWCNT/GCE. Highly water-soluble Hb protein was firmly immobilized on NIBA-IL via stable amide bonding between the free -NH2 groups of Hb and -COOH groups of NIBA-IL via EDC/NHS coupling. Thus fabricated biosensor showed a well resolved redox peak with a cathodic peak potential (E-pc) at -0.35 V and anodic peak potential (E-pa) at -0.29 V with a formal potential (E degrees') of -0.32 V, which corresponds to the deeply buried Fe-III/Fe-II redox centre of Hb, thereby direct electrochemistry of Hb was established. Further, the modified electrode demonstrated very good electrocatalytic activity towards H2O2 reduction and showed a wide linear range of detection from 0.01 to 6.3 mM with a limit of detection and sensitivity of 3.2 mu M and 111 mu A mM(-1) cm(-2), respectively. Moreover, the developed biosensor displayed high operational stability under dynamic conditions as well as during continuous potential cycles and showed reliable reproducibility. The superior performance of the fabricated biosensor is attributed to the effective covalent immobilization of Hb on the newly developed highly conducting and biocompatible NIBA-IL/MWCNT/GCE platform.
引用
收藏
页数:8
相关论文
共 48 条
[1]   Tris-imidazolium and benzimidazolium ionic liquids: a new class of biodegradable surfactants [J].
Al-Mohammed, Nassir N. ;
Hussen, Rusnah Syahila Duali ;
Alias, Yatimah ;
Abdullah, Zanariah .
RSC ADVANCES, 2015, 5 (04) :2869-2881
[2]   A MoS2-based system for efficient immobilization of hemoglobin and biosensing applications [J].
Chao, Jie ;
Zou, Min ;
Zhang, Chi ;
Sun, Haofan ;
Pan, Dun ;
Pei, Hao ;
Su, Shao ;
Yuwen, Lihui ;
Fan, Chunhai ;
Wang, Lianhui .
NANOTECHNOLOGY, 2015, 26 (27)
[3]   Recent advances in electrochemical sensing for hydrogen peroxide: a review [J].
Chen, Wei ;
Cai, Shu ;
Ren, Qiong-Qiong ;
Wen, Wei ;
Zhao, Yuan-Di .
ANALYST, 2012, 137 (01) :49-58
[4]   Hemoglobin becomes electroactive upon interaction with surface-protected Au nanoparticles [J].
del Cano, Rafael ;
Mateus, Lucia ;
Sanchez-Obrero, Guadalupe ;
Manuel Sevilla, Jose ;
Madueno, Rafael ;
Blazquez, Manuel ;
Pineda, Teresa .
TALANTA, 2018, 176 :667-673
[5]   Preparation of anion-exchangeable polymer vesicles through the self-assembly of hyperbranched polymeric ionic liquids [J].
Fan, Yujiao ;
Zhang, Dapeng ;
Wang, Jie ;
Jin, Haibao ;
Zhou, Yongfeng ;
Yan, Deyue .
CHEMICAL COMMUNICATIONS, 2015, 51 (33) :7234-7237
[6]   Fluorometric method for the determination of hydrogen peroxide and glucose with Fe3O4 as catalyst [J].
Gao, Yuan ;
Wang, Guannan ;
Huang, Hui ;
Hu, Junjie ;
Shah, Syed Mazhar ;
Su, Xingguang .
TALANTA, 2011, 85 (02) :1075-1080
[7]   Aligned copper nanowires as a cut-and-paste exclusive electrochemical transducer for free-enzyme highly selective quantification of intracellular hydrogen peroxide in cisplatin-treated cells [J].
Garcia-Carmona, Laura ;
Moreno-Guzman, Maria ;
Martin, Aida ;
Benito-Martinez, Selma ;
Fernandez-Martinez, Ana B. ;
Cristina Gonzalez, Maria ;
Lucio-Cazana, Javier ;
Escarpa, Alberto .
BIOSENSORS & BIOELECTRONICS, 2017, 96 :146-151
[8]   Polyaniline/multiwall carbon nanotubes/starch nanocomposite material and hemoglobin modified carbon paste electrode for hydrogen peroxide and glucose biosensing [J].
Gautam, Vineeta ;
Singh, Karan Pratap ;
Yadav, Vijay Laxmi .
INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2018, 111 :1124-1132
[9]   A potentiometric titration for H2O2 determination in the presence of organic compounds [J].
Gimeno, M. P. ;
Mayoral, M. C. ;
Andres, J. M. .
ANALYTICAL METHODS, 2013, 5 (06) :1510-1514
[10]   High-performance liquid chromatography method for the determination of hydrogen peroxide present or released in teeth bleaching kits and hair cosmetic products [J].
Gimeno, Pascal ;
Bousquet, Claudine ;
Lassu, Nelly ;
Maggio, Annie-Francoise ;
Civade, Corinne ;
Brenier, Charlotte ;
Lempereur, Laurent .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2015, 107 :386-393