3D rotational fluoroscopy for intraoperative clip control in patients with intracranial aneurysms - assessment of feasibility and image quality

被引:7
作者
Westermaier, Thomas [1 ]
Linsenmann, Thomas [1 ]
Homola, Gyoergy A. [2 ]
Loehr, Mario [1 ]
Stetter, Christian [1 ]
Willner, Nadine [1 ]
Ernestus, Ralf-Ingo [1 ]
Solymosi, Laszlo [2 ]
Vince, Giles H. [3 ]
机构
[1] Univ Wurzburg, Dept Neurosurg, Josef Schneider Str 11, D-97080 Wurzburg, Germany
[2] Univ Wurzburg, Dept Neuroradiol, Josef Schneider Str 11, D-97080 Wurzburg, Germany
[3] Klinikum Klagenfurt, Abt Neurochirurg, Feschnigstr 11, A-9020 Klagenfurt Am Woertherse, Austria
关键词
Aneurysm surgery; Clip control; Intraoperative; Angiography; Vessel patency; 3D fluoroscopy; Contrast; Image quality; Post-processing; DIGITAL-SUBTRACTION-ANGIOGRAPHY; INDOCYANINE GREEN VIDEOANGIOGRAPHY; CT ANGIOGRAPHY; COMPUTED-TOMOGRAPHY; DETECTOR CT; VOLUME; ARTIFACTS; DIAGNOSIS; STANDARD;
D O I
10.1186/s12880-016-0133-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Mobile 3D fluoroscopes have become increasingly available in neurosurgical operating rooms. In this series, the image quality and value of intraoperative 3D fluoroscopy with intravenous contrast agent for the evaluation of aneurysm occlusion and vessel patency after clip placement was assessed in patients who underwent surgery for intracranial aneurysms. Materials and methods: Twelve patients were included in this retrospective analysis. Prior to surgery, a 360 degrees rotational fluoroscopy scan was performed without contrast agent followed by another scan with 50 ml of intravenous iodine contrast agent. The image files of both scans were transferred to an Apple PowerMac (R) workstation, subtracted and reconstructed using OsiriX (R) free software. The procedure was repeated after clip placement. Both image sets were compared for assessment of aneurysm occlusion and vessel patency. Results: Image acquisition and contrast administration caused no adverse effects. Image quality was sufficient to follow the patency of the vessels distal to the clip. Metal artifacts reduce the assessability of the immediate vicinity of the clip. Precise image subtraction and post-processing can reduce metal artifacts and make the clip-site assessable and depict larger neck-remnants. Conclusion: This technique quickly supplies images at adequate quality to evaluate distal vessel patency after aneurysm clipping. Significant aneurysm remnants may be depicted as well. As it does not require visual control of all vessels that are supposed to be evaluated intraoperatively, this technique may be complementary to other intraoperative tools like indocyanine green videoangiography and micro-Doppler, especially for the assessment of larger aneurysms. At the momentary state of this technology, it cannot replace postoperative conventional angiography. However, 3D fluoroscopy and image post-processing are young technologies. Further technical developments are likely to result in improved image quality.
引用
收藏
页数:8
相关论文
共 25 条
[1]   Computed tomographic angiography versus digital subtraction angiography for the diagnosis and early treatment of ruptured intracranial aneurysms [J].
Anderson, GB ;
Steinke, DE ;
Petruk, KC ;
Ashforth, R ;
Findlay, JM .
NEUROSURGERY, 1999, 45 (06) :1315-1320
[2]   Impact of Indocyanine Green Videoangiography on Rate of Clip Adjustments Following Intraoperative Angiography [J].
Caplan, Justin M. ;
Sankey, Eric ;
Yang, Wuyang ;
Radvany, Martin G. ;
Colby, Geoffrey P. ;
Coon, Alexander L. ;
Tamargo, Rafael J. ;
Huang, Judy .
NEUROSURGERY, 2014, 75 (04) :437-443
[3]  
Cardinale F., 2012, Stereotaxy and Epilepsy Surgery, V1st, P245
[4]   Near-infrared indocyanine green videoangiography versus microvascular Doppler sonography in aneurysm surgery [J].
Fischer, Gerrit ;
Stadie, Axel ;
Oertel, Joachim M. K. .
ACTA NEUROCHIRURGICA, 2010, 152 (09) :1519-1525
[5]   Dose reduction in 64-row whole-body CT in multiple trauma: an optimized CT protocol with iterative image reconstruction on a gemstone-based scintillator [J].
Geyer, Lucas L. ;
Koerner, Markus ;
Harrieder, Andreas ;
Mueck, Fabian G. ;
Deak, Zsuzsanna ;
Wirth, Stefan ;
Linsenmaier, Ulrich .
BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1061)
[6]   Feasibility of Intravenous Flat Panel Detector CT Angiography for Intracranial Arterial Stenosis [J].
Jeon, J. S. ;
Sheen, S. H. ;
Hwang, G. J. ;
Kim, H. C. ;
Kwon, B. J. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (01) :129-134
[7]   C-arm flat detector computed tomography: the technique and its applications in interventional neuro-radiology [J].
Kamran, Mudassar ;
Nagaraja, Sanjoy ;
Byrne, James V. .
NEURORADIOLOGY, 2010, 52 (04) :319-327
[8]   Fusion of Intraoperative Three-Dimensional Rotational Angiography and Flat-Panel Detector Computed Tomography for Cerebrovascular Neuronavigation [J].
Leng, Lewis Z. ;
Rubin, David G. ;
Patsalides, Athos ;
Riina, Howard A. .
WORLD NEUROSURGERY, 2013, 79 (3-4) :504-509
[9]   Detectability of hepatic tumors during 3D post-processed ultrafast cone-beam computed tomography [J].
Paul, Jijo ;
Vogl, Thomas J. ;
Chacko, Annamma .
PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (20) :8109-8127
[10]   Radiation dose and image quality of X-ray volume imaging systems: cone-beam computed tomography, digital subtraction angiography and digital fluoroscopy [J].
Paul, Jijo ;
Jacobi, Volkmar ;
Farhang, Mohammad ;
Bazrafshan, Babak ;
Vogl, Thomas J. ;
Mbalisike, Emmanuel C. .
EUROPEAN RADIOLOGY, 2013, 23 (06) :1582-1593