Does 16-slice multidetector computed tomography improve stent patency and in-stent restenosis evaluation?

被引:1
作者
Ligabue, Guido
Fiocchi, Federica
Ferraresi, Sonia
Rossi, Rosario
Modena, Maria Grazia
Ratti, Carlo
Torricelli, Pietro
Romagnoli, Renato
机构
[1] Univ Modena & Reggio Emilia, Azienda Ospedaliero Univ Policlin Modena, Dipartimento Integrato Emergenza Urgenza, Cattedra & Serv Radiol 1, Modena, Italy
[2] Univ Modena & Reggio Emilia, Azienda Ospedaliero Univ Policlin Modena, Dipartimento Integrato Emergenza Urgenza, Cattedra & Serv Cardiol, Modena, Italy
关键词
coronary angiography; multidetector computed tomography; restenoses; stent;
D O I
10.2459/01.JCM.0000269717.41059.86
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim To assess the value of multidetector computed tomography (MDCT) in the non-invasive evaluation of stents. Methods We studied 88 patients (142 stents): 48 with 1.2-mm MDCT, 40 with 0.6-mm MDCT considering accuracy in assessing the vessel lumen, stent patency and intra-stent restenosis. Coronary angiography comprised the gold standard. Results Occlusion was detected, respectively, in three of 72 versus four of 70 cases. Patency was assessed in all cases. In-stent restenosis was diagnosed in two of eight cases with thin-slice MDCT. Conclusions 0.6-mm MDCT allows a better visualization of stent lumen and in-stent restenosis versus 1.2-mm MDCT.
引用
收藏
页码:438 / 444
页数:7
相关论文
共 13 条
[1]   Impact of coronary artery stents on mortality and nonfatal myocardial infarction: Meta-analysis of randomized trials comparing a strategy of routine stenting with that of balloon angioplasty [J].
Al Suwaidi, J ;
Holmes, DR ;
Salam, AM ;
Lennon, R ;
Berger, PB .
AMERICAN HEART JOURNAL, 2004, 147 (05) :815-822
[2]   Acute and chronic tissue response to coronary stent implantation:: Pathologic findings in human specimen [J].
Grewe, PH ;
Deneke, T ;
Machraoui, A ;
Barmeyer, J ;
Müller, KM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (01) :157-163
[3]   Noninvasive coronary angiography with 16-detector row CT: Effect of heart rate [J].
Hoffmann, MHK ;
Shi, HS ;
Manzke, R ;
Schmid, FT ;
De Vries, L ;
Grass, M ;
Brambs, HR ;
Aschoff, AJ .
RADIOLOGY, 2005, 234 (01) :86-97
[4]   Assessment of coronary artery stent patency by electron-beam CT [J].
Knollmann, FD ;
Möller, J ;
Gebert, A ;
Bethge, C ;
Felix, R .
EUROPEAN RADIOLOGY, 2004, 14 (08) :1341-1347
[5]   Multislice CT in cardiac and coronary angiography [J].
Kopp, AF ;
Küttner, A ;
Trabold, T ;
Heuschmid, M ;
Schröder, S ;
Claussen, CD .
BRITISH JOURNAL OF RADIOLOGY, 2004, 77 :S87-S97
[6]   Multislice spiral computed tomography for the detection of coronary stent restenosis and patency [J].
Krüger, S ;
Mahnken, AH ;
Sinha, AM ;
Borghans, A ;
Dedden, K ;
Hoffmann, R ;
Hanrath, P .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2003, 89 (2-3) :167-172
[7]   Coronary artery stents in multislice computed tomography -: In vitro artifact evaluation [J].
Mahnken, AH ;
Buecker, A ;
Wildberger, JE ;
Ruebben, A ;
Stanzel, S ;
Vogt, F ;
Günther, RW ;
Blindt, R .
INVESTIGATIVE RADIOLOGY, 2004, 39 (01) :27-33
[8]  
Maintz D, 2003, INVEST RADIOL, V38, P790, DOI 10.1097/01.rli.0000086495.96457.54
[9]   64-slice multidetector coronary CT angiography:: in vitro evaluation of 68 different stents [J].
Maintz, D ;
Seifarth, H ;
Raupach, R ;
Flohr, T ;
Rink, M ;
Sommer, T ;
Özgün, M ;
Heindel, W ;
Fischbach, R .
EUROPEAN RADIOLOGY, 2006, 16 (04) :818-826
[10]   Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction [J].
Ropers, D ;
Baum, U ;
Pohle, K ;
Anders, K ;
Ulzheimer, S ;
Ohnesorge, B ;
Schlundt, C ;
Bautz, W ;
Daniel, WG ;
Achenbach, S .
CIRCULATION, 2003, 107 (05) :664-666