Optimal Stent-Sizing With Intravascular Ultrasound Contributes to Complete Neointimal Coverage After Sirolimus-Eluting Stent Implantation Assessed by Angioscopy

被引:17
|
作者
Sera, Fusako [2 ]
Awata, Masaki [2 ]
Uematsu, Masaaki [2 ]
Kotani, Jun-ichi [1 ]
Nanto, Shinsuke [1 ,2 ]
Nagata, Seiki [2 ]
机构
[1] Osaka Univ, Grad Sch Med, Dept Adv Cardiovasc Therapeut, Suita, Osaka 5650871, Japan
[2] Kansai Rosai Hosp, Ctr Cardiovasc, Amagasaki, Hyogo, Japan
关键词
angioscopy; intravascular ultrasound; neointima; sirolimus-eluting stent; PALMAZ-SCHATZ STENTS; CORONARY-ARTERY; LATE THROMBOSIS; ANTIPLATELET THERAPY; MORPHOLOGIC CHANGES; RADIATION-THERAPY; CLINICAL-TRIALS; TIME-COURSE; RESTENOSIS; PREDICTORS;
D O I
10.1016/j.jcin.2009.07.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives The aim of this study was to explore the determinants of neointimal coverage after sirolimus-eluting stent (SES). Background Although SES has significantly reduced in-stent restenosis by inhibiting neointimal hyperplasia, insufficient neointimal coverage after stenting might result in adverse outcomes. Methods We evaluated 28 SES lesions with both angioscopy and intravascular ultrasound (IVUS). Quantitative assessments of the lesions and stent expansion were performed by IVUS at the time of stent implantation, and degree of neointimal coverage was judged by angioscopy at follow-up (11 +/- 6 months) whether the stent struts were embedded by the neointima ("complete/incomplete" neointimal coverage). Results "Complete" coverage was identified in 10 (36%), and "incomplete" coverage was identified in 18 (64%). Time from the stenting to angioscopy as well as the lesion and procedural characteristics were similar between the complete and incomplete coverage groups. The IVUS parameters were also similar, except for the final minimum stent cross-sectional area (CSA) (7.0 +/- 1.8 mm(2) in complete vs. 5.3 +/- 1.9 mm(2) in incomplete, p = 0.02) and lumen CSA at the distal reference site (6.1 +/- 1.4 mm(2) in complete vs. 4.9 +/- 1.2 mm(2) in incomplete, p = 0.02). The ratio of the stent area to the vessel area was significantly larger in the complete coverage than in the incomplete coverage group (0.52 +/- 0.11 vs. 0.39 +/- 0.09, p = 0.002). Conclusions Adequate stent sizing relative to the vessel size might contribute to the angioscopically complete neointimal coverage after SES implantation. (J Am Coll Cardiol Intv 2009;2:989-94) (c) 2009 by the American College of Cardiology Foundation
引用
收藏
页码:989 / 994
页数:6
相关论文
共 50 条
  • [41] Serial angiographic and intravascular ultrasound evaluation to interrogate the presence of late “catch-up” phenomenon after cypher® sirolimus-eluting stent implantation
    Daniel Chamié
    Alexandre Abizaid
    J. Ribamar Costa
    Fausto Feres
    J. Fábio Almiro da Silva
    Luiz Alberto P. Mattos
    Rodolfo Staico
    Ricardo A. Costa
    Andréa Abizaid
    Luiz Fernando L. Tanajura
    Amanda G. M. R. Sousa
    J. Eduardo Sousa
    The International Journal of Cardiovascular Imaging, 2011, 27 : 867 - 874
  • [42] Impact of preinterventional plaque composition and eccentricity on late-acquired incomplete stent apposition after sirolimus-eluting stent implantation: an intravascular ultrasound radiofrequency analysis
    Sato, Takao
    Kameyama, Tomoki
    Noto, Takahisa
    Nozawa, Takashi
    Inoue, Hiroshi
    CORONARY ARTERY DISEASE, 2012, 23 (07) : 432 - 437
  • [43] Incidence, Risk Factors, and Clinical Sequelae of Angiographic Peri-Stent Contrast Staining After Sirolimus-Eluting Stent Implantation
    Imai, Masao
    Kadota, Kazushige
    Goto, Tsuyoshi
    Fujii, Satoki
    Yamamoto, Hiroyuki
    Fuku, Yasushi
    Hosogi, Shingo
    Hirono, Akitoshi
    Tanaka, Hiroyuki
    Tada, Takeshi
    Morimoto, Takeshi
    Shiomi, Hiroki
    Kozuma, Ken
    Inoue, Katsumi
    Suzuki, Nobuaki
    Kimura, Takeshi
    Mitsudo, Kazuaki
    CIRCULATION, 2011, 123 (21) : 2382 - 2391
  • [44] Intravascular ultrasound assessed incomplete stent apposition and stent fracture in stent thrombosis after bare metal versus drug-eluting stent treatment the Nordic Intravascular Ultrasound Study (NIVUS)
    Kosonen, Petteri
    Vikman, Saila
    Jensen, Lisette Okkels
    Lassen, Jens Flensted
    Harnek, Jan
    Olivecrona, Goran K.
    Erglis, Andrejs
    Fossum, Eigil
    Niemela, Matti
    Kervinen, Kari
    Ylitalo, Antti
    Pietila, Mikko
    Aaroe, Jens
    Kellerth, Thomas
    Saunamaki, Kari
    Thayssen, Per
    Hellsten, Lars
    Thuesen, Leif
    Niemela, Kari
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (02) : 1010 - 1016
  • [45] Restenosis and stent fracture following sirolimus-eluting stent (SES) implantation - A serial quantitative coronary angiography (QCA) and intravascular ultrasound (IVUS) study
    Okumura, Masanori
    Ozaki, Yukio
    Ishii, Junichi
    Kan, Shino
    Naruse, Hiroyuki
    Matsui, Shigeru
    Ishikawa, Makoto
    Hattori, Kousuke
    Gochi, Tomoko
    Nakano, Tadashi
    Yamada, Akira
    Kato, Shigeru
    Motoyama, Sadako
    Sarai, Masayoshi
    Takagi, Yasushi
    Ismail, Tevfik F.
    Nomura, Masanori
    Hishida, Hitoshi
    CIRCULATION JOURNAL, 2007, 71 (11) : 1669 - 1677
  • [46] Difference in neointimal coverage at chronic stage between bare metal stent and sirolimus-eluting stent evaluated at stent-strut level by optical coherence tomography
    Shinichiro Ikuta
    Kazuhiro Kobuke
    Yoshitaka Iwanaga
    Yoshifumi Nakauchi
    Kenji Yamaji
    Shunichi Miyazaki
    Heart and Vessels, 2014, 29 : 320 - 327
  • [47] Serial Intravascular Ultrasound Analysis of Peri-Stent Remodeling and Proximal and Distal Edge Effects After Sirolimus-Eluting or Paclitaxel-Eluting Stent Implantation in Patients With Diabetes Mellitus
    Jensen, Lisette Okkels
    Maeng, Michael
    Mintz, Gary S.
    Christiansen, Evald Hoej
    Hansen, Knud Noerregaard
    Galloe, Anders
    Kelbaek, Henning
    Lassen, Jens Flensted
    Thuesen, Leif
    Thayssen, Per
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 103 (08) : 1083 - 1088
  • [49] Relationship between Stent Malapposition and Incomplete Neointimal Coverage after Drug-Eluting Stent Implantation
    Kim, Byeong-Keuk
    Hong, Myeong-Ki
    Shin, Dong-Ho
    Kim, Jung-Sun
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2012, 25 (03) : 270 - 277
  • [50] Persistent inhibition of neointimal hyperplasia after sirolimus-eluting stent implantation - Long-term (up to 2 years) clinical, angiographic, and intravascular ultrasound follow-up
    Degertekin, M
    Serruys, PW
    Foley, DP
    Tanabe, K
    Regar, E
    Vos, J
    Smits, PC
    van der Giessen, WJ
    van den Brand, M
    de Feyter, P
    Popma, JJ
    CIRCULATION, 2002, 106 (13) : 1610 - 1613