Management of vaginal erosion of polypropylene mesh slings

被引:138
作者
Kobashi, KC [1 ]
Govier, FE [1 ]
机构
[1] Continence Ctr Virginia Mason, Seattle, WA USA
关键词
urethra; urinary incontinence; stress; postoperative complications; surgical mesh; polypropylene;
D O I
10.1097/01.ju.0000060119.43064.f6
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: The SPARC (American Medical Systems, Minneapolis, Minnesota) polypropylene sting has recently been introduced as an alternative delivery system to TVT (Ethicon, New Brunswick, New Jersey) tension-free vaginal tape for placement of a tension-free mid urethral sling. Erosion must always be considered a risk of synthetic materials. We present 4 cases of vaginal erosion of polypropylene mesh placed with this system and the successful conservative management done. Materials and Methods: A total of 90 patients received a SPARC polypropylene pubovaginal sling at our institution between October 1, 2001 and October 1, 2002. During followup 3 of our patients and 1 patient with tension-free vaginal tape who was referred from elsewhere presented with vaginal exposure of the mesh. Results: Two patients described persistent vaginal discharge 6 weeks postoperatively, including 1 who complained primarily of partner discomfort during sexual intercourse. Two patients were completely asymptomatic and mesh erosion was discovered at routine physical examination 6 weeks postoperatively. Pelvic examination demonstrated vaginal exposure of the mesh in all cases. Each patient was observed conservatively and 3 months postoperatively all 4 had complete spontaneous epithelialization over the mesh. None had stress incontinence, urgency or urge incontinence, all emptied the bladder to completion and all patients were completely satisfied with the procedure. Conclusions: The recent literature suggests that polypropylene mesh erosion should be treated with complete removal of the sling material. We present 4 cases of vaginal erosion of polypropylene slings that were managed conservatively with observation and resulted in complete spontaneous healing. Sling preservation with continued patient continence and satisfaction is a feasible option in those with vaginal exposure of polypropylene mesh.
引用
收藏
页码:2242 / 2243
页数:2
相关论文
共 15 条
  • [11] THE MARLEX SLING OPERATION FOR THE TREATMENT OF RECURRENT STRESS URINARY-INCONTINENCE - A 16-YEAR REVIEW
    MORGAN, JE
    FARROW, GA
    STEWART, FE
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1985, 151 (02) : 224 - 226
  • [12] SILASTIC SLING FOR URETHRAL SPHINCTER INCOMPETENCE IN WOMEN
    STANTON, SL
    BRINDLEY, GS
    HOLMES, DM
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1985, 92 (07): : 747 - 750
  • [13] The Gore-tex sling procedure for female sphincteric incontinence: indications, technique, and results
    Staskin, DR
    Choe, JM
    Breslin, DS
    [J]. WORLD JOURNAL OF UROLOGY, 1997, 15 (05) : 295 - 299
  • [14] Polypropylene mesh tape for stress urinary incontinence: Complications of urethral erosion and outlet obstruction
    Sweat, SD
    Itano, NB
    Clemens, JQ
    Bushman, W
    Gruenenfelder, J
    McGuire, EJ
    Lightner, DJ
    [J]. JOURNAL OF UROLOGY, 2002, 168 (01) : 144 - 146
  • [15] Ulmsten U, 1996, Int Urogynecol J Pelvic Floor Dysfunct, V7, P81, DOI 10.1007/BF01902378