Analysis of total arsenic, total selenium and total chromium in urine by inductively coupled plasma-dynamic reaction cell-mass spectrometry

被引:36
作者
McShane, William J.
Pappas, R. Steven
Paschal, Dan
机构
[1] Ctr Dis Control & Prevent, Div Sci Lab, Battelle, Atlanta, GA 30341 USA
[2] Ctr Dis Control & Prevent, Div Sci Lab, Atlanta, GA 30341 USA
关键词
D O I
10.1039/b613884e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An accurate and simple method for the determination of total arsenic, total selenium and total chromium in urine has been developed using inductively coupled argon plasma- dynamic reaction cell- mass spectrometry ( ICP- DRC- MS). Determination was by external calibration, using matrixmatched standards and high purity calibration materials from a commercial vendor. Aliquots of each urine specimen were diluted (1 + 9) with 2% (v/v) nitric acid containing rhodium and iridium as an internal standard. Argon cell gas was used to remove the isobaric interferences that normally adversely a. ect As-75, Se-78 and Cr-52 analysis by ICP- MS and require the use of a dynamic reaction cell (DRC). The principle isobars that interfere with these measurements are [(ArCl)-Ar-40-Cl-35](+), [(ArAr)-Ar-40-Ar-38](+) and [(ArC)-Ar-40-C-12](+) for(75) As, Se-78 and Cr-52, respectively. The counts at m/z 75 (arsenic); 78 (selenium); 52 (chromium), 103 (rhodium), and 193 ( iridium) were measured. The ratios of the counts at m/z 75 or 78 to those at m/z 193, and m/z 52 to those at m/z 103 were calculated. These ratios were compared with those from urine- based calibration standards to calculate the arsenic, selenium, and chromium concentrations in unknown specimens. The concentrations of arsenic, selenium, and chromium were calculated as mu g L-1 in the sample. No creatinine corrections were made, although these could easily be made with data for urine creatinine for each specimen. The proposed method uses the same diluted urine solutions prepared for conventional ICP- MS toxic metal biomonitoring and chemical terrorism screening analysis with the same internal standards; and uses argon as the DRC cell gas. The proposed method provides the basis for an accurate method for determining total arsenic, total selenium, and total chromium in unexposed subjects, and in persons considered to be exposed to those elements through chemical terrorism, environmental, nutritional or other pathways. Approximately 100 specimens, including blanks, calibration standards and quality-control materials, can be processed in an 8 h day.
引用
收藏
页码:630 / 635
页数:6
相关论文
共 21 条
[11]   Selenium speciation in human urine samples by LC- and CE-ICP-MS-separation and identification of selenosugars [J].
Gammelgaard, B ;
Bendahl, L .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (01) :135-142
[12]   Fast, simple and reliable routine determination of 23 elements in urine by ICP-MS [J].
Heitland, P ;
Köster, HD .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (12) :1552-1558
[13]   Evaluation of an ICP-collision/reaction cell-MS system for the sensitive determination of spectrally interfered and non-interfered elements using the same gas conditions [J].
Iglesias, M ;
Gilon, N ;
Poussel, E ;
Mermet, JM .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (10) :1240-1247
[14]  
JARRETT J, 2002, 0160C010D CDC CLIA
[15]  
Khan AS, 2001, PUBLIC HEALTH REP, V116, P3, DOI 10.1093/phr/116.1.3
[16]  
MEI Y, 1994, J AM SOC MASS SPECTR, V5, P845
[17]   Comparison of tunable bandpass reaction cell inductively coupled plasma mass spectrometry with conventional inductively coupled plasma mass spectrometry for the determination of heavy metals in whole blood and urine [J].
Nixon, DE ;
Neubauer, KR ;
Eckdahl, SJ ;
Butz, JA ;
Burritt, MF .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (09) :1377-1387
[18]  
PASCHAL D, 2005, CDC CLIA METHOD TMS
[19]   ATTENUATION OF POLYATOMIC ION INTERFERENCES IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY BY GAS-PHASE COLLISIONS [J].
ROWAN, JT ;
HOUK, RS .
APPLIED SPECTROSCOPY, 1989, 43 (06) :976-980
[20]  
TAYLOR JK, 1986, CHEMTECH, V16, P756