A calibrated atomic force microscope using an orthogonal scanner and a calibrated laser interferometer

被引:16
|
作者
Lee, Dong-Yeon
Kim, Dong-Min
Gweon, Dae-Gab
Park, Jinwon
机构
[1] Korea Adv Inst Sci & Technol, Dept Engn Mech, Taejon 307701, South Korea
[2] KRISS, Div Opt Metrol, Taejon 305340, South Korea
关键词
calibrated atomic force microscope; laser interferometer; orthogonal scanner; flexure-guide;
D O I
10.1016/j.apsusc.2006.08.027
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A compact and two-dimensional atomic force microscope (AFM) using an orthogonal sample scanner, a calibrated homodyne laser interferometer and a commercial AFM head was developed for use in the nano-metrology field. The x and y position of the sample with respect to the tip are acquired by using the laser interferometer in the open-loop state, when each z data point of the AFM head is taken. The sample scanner, which has a motion amplifying mechanism was designed to move a sample up to 100 mu m x 100 mu m in orthogonal way, which means less crosstalk between axes. Moreover, the rotational errors between axes are measured to ensure the accuracy of the calibrated AFM within the full scanning range. The conventional homodyne laser interferometer was used to measure the x and y displacements of the sample and compensated via an X-ray interferometer to reduce the nonlinearity of the optical interferometer. The repeatability of the calibrated AFM was measured to sub-nanometers within a few hundred nanometers scanning range. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:3945 / 3951
页数:7
相关论文
共 50 条
  • [41] FORCE MEASUREMENT USING AN AC ATOMIC FORCE MICROSCOPE
    DUCKER, WA
    COOK, RF
    CLARKE, DR
    JOURNAL OF APPLIED PHYSICS, 1990, 67 (09) : 4045 - 4052
  • [42] Scanning (atomic) force microscopy imaging of earthworm haemoglobin calibrated with spherical colloidal gold particles
    Xu, S
    Arnsdorf, MF
    JOURNAL OF MICROSCOPY-OXFORD, 1997, 187 : 43 - 53
  • [43] Automatic approaching method for atomic force microscope using a Gaussian laser beam
    Han, Cheolsu
    Lee, Haiwon
    Chung, Choo
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2009, 80 (07):
  • [44] FORCE MICROSCOPE USING A TWIN-PATH INTERFEROMETER
    WATANABE, S
    HANE, K
    GOTO, T
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1992, 10 (01): : 1 - 5
  • [45] Scanning force microscope using point diffraction interferometer
    Mou, XD
    You, YF
    Zhuo, YM
    Yang, YY
    Xu, M
    METROLOGY, INSPECTION, AND PROCESS CONTROL FOR MICROLITHOGRAPHY XII, 1998, 3332 : 482 - 487
  • [46] LASER THERMAL EFFECTS ON ATOMIC FORCE MICROSCOPE CANTILEVERS
    ALLEGRINI, M
    ASCOLI, C
    BASCHIERI, P
    DINELLI, F
    FREDIANI, C
    LIO, A
    MARIANI, T
    ULTRAMICROSCOPY, 1992, 42 : 371 - 378
  • [47] Study of laser beam tracking atomic force microscope
    State Key Laboratory of Modern Optical Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou, China
    Guangdianzi Jiguang, 9 (1719-1723):
  • [48] Lateral force microscope calibration using a modified atomic force microscope cantilever
    Reitsma, M. G.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2007, 78 (10):
  • [49] Calibrated Phase-Shifting Digital Holographic Microscope Using a Sampling Moire Technique
    Xia, Peng
    Wang, Qinghua
    Ri, Shien
    Tsuda, Hiroshi
    APPLIED SCIENCES-BASEL, 2018, 8 (05):
  • [50] Time-calibrated estimates of oceanographic profiles using empirical orthogonal functions and clustering
    Hjelmervik, Karina
    Hjelmervik, Karl Thomas
    OCEAN DYNAMICS, 2014, 64 (05) : 655 - 665