Lateral flow assays (LFA) for detection of pathogenic bacteria: A small point-of-care platform for diagnosis of human infectious diseases

被引:80
|
作者
Sohrabi, Hessamaddin [1 ]
Majidi, Mir Reza [1 ]
Fakhraei, Mina [1 ]
Jahanban-Esfahlan, Ali [2 ,3 ]
Hejazi, Maryam [4 ]
Oroojalian, Fatemeh [5 ]
Baradaran, Behzad [6 ]
Tohidast, Maryam [6 ]
de la Guardia, Miguel [7 ]
Mokhtarzadeh, Ahad [6 ]
机构
[1] Univ Tabriz, Fac Chem, Dept Analyt Chem, Tabriz 516661647, Iran
[2] Tabriz Univ Med Sci, Kidney Res Ctr, Tabriz, Iran
[3] Tabriz Univ Med Sci, Biotechnol Res Ctr, Tabriz, Iran
[4] Univ Tehran Med Sci, Chron Dis Res Ctr, Endocrinol & Metab Populat Sci Inst, Tehran, Iran
[5] North Khorasan Univ Med Sci, Sch Med, Dept Adv Sci & Technol Med, Bojnurd, Iran
[6] Tabriz Univ Med Sci, Immunol Res Ctr, Tabriz, Iran
[7] Univ Valencia, Dept Analyt Chem, Dr Moliner 50, Valencia 46100, Spain
关键词
Point-of-care testing (POCT) diagnosis; Lateral-flow immunoassay (LFA); Pathogenic bacteria; Sensing and biosensing assays; Recognition elements; BACILLUS-ANTHRACIS SPORES; COMPREHENSIVE LABORATORY EVALUATION; ESCHERICHIA-COLI O157H7; VIBRIO-CHOLERAE O1; COMBINED IMMUNOMAGNETIC SEPARATION; MEDIATED ISOTHERMAL AMPLIFICATION; SUSPICIOUS WHITE POWDERS; ON-SITE DETECTION; RAPID DETECTION; LISTERIA-MONOCYTOGENES;
D O I
10.1016/j.talanta.2022.123330
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Up-to-date diagnostics is globally improved by point-of-care testing (POCT) analysis and bedside research works. Development in POCT analysis has been provided mostly by forward-looking engineering technology for biosensing and sensing assessments. Lately, lateral flow assays (LFAs) have attracted a lot of interest as a result of their noteworthy benefits including cost-effectiveness, better portability, being operator friendly and rapid detection. This technique has been employed broadly for monitoring diverse biomarkers linked to ultrasensitive detection of pathogenic bacteria, ecological monitoring, consumer protection, and infectious diseases. LFA analyses established on qualitative and optical outcomes have boosted the objectivity and data efficiency of the assessments. Therefore, developing novel methods with the capability of providing reliable and quantitative information regarding a target analyte in a model and preserving the qualities of LFAs is of great necessity. In this review, the main principles of LFAs, challenges, and prospects for more development in this field in sensing pathogenic bacteria have been summarized. Subsequently, visually-read LFAs improvement to further progressive platforms have been explored by considering the prospects of this very flexible method for ultrasensitive detection of pathogenic bacteria. In addition, novel labeling methodologies, electrochemical and optical transducers are described. Also, recent developments in these detection methods elements in combination with other considered approaches have been highlighted.
引用
收藏
页数:24
相关论文
共 28 条
  • [21] Signal-Boosted Electrochemical Lateral Flow Immunoassay for Early Point-of-Care Detection of Liver Cancer Biomarker
    Shi, Dongmin
    Yin, Yilin
    Li, Xiaoyuan
    Yuan, Jie
    ACS SENSORS, 2024, 9 (10): : 5293 - 5301
  • [22] A paper microfluidics-based fluorescent lateral flow immunoassay for point-of-care diagnostics of non-communicable diseases
    Natarajan, Satheesh
    Su, Fengmei
    Jayaraj, Joseph
    Shah, Malay I. Iesh
    Huang, Youju
    ANALYST, 2019, 144 (21) : 6291 - 6303
  • [23] Non-Invasive Point-of-Care Detection of Methamphetamine and Cocaine via Aptamer-Based Lateral Flow Test
    Erkocyigit, Bilge
    Man, Ezgi
    Efecan, Ece
    Ozufuklar, Ozge
    Devecioglu, Deniz
    Bagci, Basak
    Aldemir, Ebru
    Coskunol, Hakan
    Evran, Serap
    Celik, Emine Guler
    BIOSENSORS-BASEL, 2025, 15 (01):
  • [24] A gold nanoparticle-based lateral flow immunoassay for atrazine point-of-care detection using a handhold scanning device as reader
    Sun, Tieqiang
    Xu, Zehua
    Yuan, Shuai
    Liu, Xiao
    Chen, Zongfen
    Han, Zhenyu
    Liu, Wentao
    Fan, Longxing
    Yang, Han
    Qie, Zhiwei
    Ning, Baoan
    MICROCHIMICA ACTA, 2022, 189 (04)
  • [25] Point-of-care and visual detection of P. aeruginosa and its toxin genes by multiple LAMP and lateral flow nucleic acid biosensor
    Chen, Yuting
    Cheng, Nan
    Xu, Yuancong
    Huang, Kunlun
    Luo, Yunbo
    Xu, Wentao
    BIOSENSORS & BIOELECTRONICS, 2016, 81 : 317 - 323
  • [26] Point-of-Care Lateral Flow Detection of Viable Escherichia coli O157:H7 Using an Improved Propidium Monoazide-Recombinase Polymerase Amplification Method
    Rani, Alka
    Dike, Charles Chinyere
    Mantri, Nitin
    Ball, Andrew
    FOODS, 2022, 11 (20)
  • [27] A Review of the Nucleic Acid-Based Lateral Flow Assay for Detection of Breast Cancer from Circulating Biomarkers at a Point-of-Care in Low Income Countries
    Dyan, Busiswa
    Seele, Palesa Pamela
    Skepu, Amanda
    Mdluli, Phumlane Selby
    Mosebi, Salerwe
    Sibuyi, Nicole Remaliah Samantha
    DIAGNOSTICS, 2022, 12 (08)
  • [28] SMART-LAMP: A Smartphone-Operated Handheld Device for Real-Time Colorimetric Point-of-Care Diagnosis of Infectious Diseases via Loop-Mediated Isothermal Amplification
    Garcia-Bernalt Diego, Juan
    Fernandez-Soto, Pedro
    Marquez-Sanchez, Sergio
    Santos Santos, Daniel
    Febrer-Sendra, Begona
    Crego-Vicente, Beatriz
    Luis Munoz-Bellido, Juan
    Belhassen-Garcia, Moncef
    Corchado Rodriguez, Juan M.
    Muro, Antonio
    BIOSENSORS-BASEL, 2022, 12 (06):