Capsule phase microextraction of selected polycyclic aromatic hydrocarbons from water samples prior to their determination by gas chromatography-mass spectrometry

被引:18
作者
Manousi, N. [1 ]
Kabir, A. [2 ]
Furton, K. G. [2 ]
Rosenberg, E. [3 ]
Zachariadis, G. A. [1 ]
机构
[1] Aristotle Univ Thessaloniki, Dept Chem, Lab Analyt Chem, Thessaloniki 54124, Greece
[2] Florida Int Univ, Int Forens Res Inst, Dept Chem & Biochem, Miami, FL 33199 USA
[3] Vienna Univ Technol, Inst Chem Technol & Analyt, A-1060 Vienna, Austria
关键词
Capsule phase microextraction; GC-MS; Polycyclic aromatic hydrocarbons; Sample preparation; Water samples; EXTRACTION; ADSORBENT; NANOTUBES;
D O I
10.1016/j.microc.2021.106210
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Capsule phase microextraction (CPME) is a recently introduced environmentally friendly sample preparation technique that integrates both filtration and stirring mechanism into the extraction device. In this study, CPME was employed for the first time for the extraction of four polycyclic aromatic hydrocarbons (naphthalene, fluorene, phenanthrene and pyrene) from water samples prior to their determination by gas chromatography-mass spectrometry (GC-MS). The microextraction capsules were made of two porous polypropylene tubes that are welded to each other; one tube contained the magnetic rod, and the other tube contained the sorbent. Various sol-gel hybrid sorbents were evaluated. Microextraction capsules containing sol-gel poly(caprolactone)-poly (dimethylsiloxane)-poly(caprolactone) (PCAP-PDMS-PCAP) sorbent provided the highest extraction efficiency. The main parameters (e.g., adsorption time, sample volume, stirring rate, addition of salt, type of eluent, desorption time and elution volume) affecting the steps of the CPME procedure were evaluated. Under the selected conditions, limits of detection (signal/noise = 3.3) ranged between 0.03 and 0.07 ng mL-1 for the selected PAHs. The relative standard deviation for the within-day and between-days repeatability were lower than 7.7% and 8.5%, respectively. Moreover, the CPME method exhibited good linearity and reusability of the microextraction capsules. The method was successfully applied to the analysis of tap water, mineral water and lake water samples. Relative recoveries ranged between 94.3 and 109.8%. The herein reported green method could efficiently simplify the overall sample preparation process, since it overcomes the requirements of sample filtration before the extraction and the solvent evaporation and sample reconstitution after the extraction.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Determination of Polycyclic Aromatic Hydrocarbons and Halogenated Polycyclic Aromatic Hydrocarbons in Vegetable by Gas Chromatography-Tandem Mass Spectrometry
    Wang Li
    Jin Fen
    Li Min-Jie
    Liu Yue
    Jiao Bi-Ning
    Shao Hua
    Jin Mao-Jun
    Wang Jing
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 41 (06) : 869 - 875
  • [32] Identification and quantification of pesticides and polycyclic aromatic hydrocarbons in water and food by gas chromatography-mass spectrometry
    V. G. Amelin
    T. B. Nikeshina
    A. V. Tret’yakov
    Journal of Analytical Chemistry, 2011, 66 : 918 - 923
  • [33] A solid phase microextraction Arrow with zirconium metal-organic framework/molybdenum disulfide coating coupled with gas chromatography-mass spectrometer for the determination of polycyclic aromatic hydrocarbons in fish samples
    Yuan, Yongli
    Lin, Xiaoting
    Li, Tianhua
    Pang, Tianyu
    Dong, Youren
    Zhuo, Rongjie
    Wang, Qiqin
    Cao, Yuting
    Gan, Ning
    JOURNAL OF CHROMATOGRAPHY A, 2019, 1592 : 9 - 18
  • [34] Determination of Polycyclic Aromatic Hydrocarbons in Coffee and Coffee Substitutes using Dispersive SPE and Gas Chromatography-Mass Spectrometry
    Sadowska-Rociek, Anna
    Surma, Magdalena
    Cieslik, Ewa
    FOOD ANALYTICAL METHODS, 2015, 8 (01) : 109 - 121
  • [35] Ultra-sensitive solid-phase Microextraction-Gas Chromatography-Mass spectrometry determination of polycyclic aromatic hydrocarbons in snow samples using a deep cavity BenzoQxCavitand
    Riboni, N.
    Amorini, M.
    Bianchi, F.
    Pedrini, A.
    Pinalli, R.
    Dalcanale, E.
    Careri, M.
    CHEMOSPHERE, 2022, 303
  • [36] Solid phase microextraction combined with gas chromatography-mass spectrometry for the determination of diquat residues in water
    Gao, Lina
    Liu, Guojie
    Zhu, Juan
    Wang, Chunyuan
    Liu, Junting
    JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 70 (05) : 552 - 557
  • [37] Solid phase microextraction combined with gas chromatography-mass spectrometry for the determination of diquat residues in water
    Lina Gao
    Guojie Liu
    Juan Zhu
    Chunyuan Wang
    Junting Liu
    Journal of Analytical Chemistry, 2015, 70 : 552 - 557
  • [38] Characterisation of polycyclic aromatic hydrocarbons in atmospheric aerosols by gas chromatography-mass spectrometry
    Borras, E.
    Tortajada-Genaro, L. A.
    ANALYTICA CHIMICA ACTA, 2007, 583 (02) : 266 - 276
  • [39] Accelerated solvent extraction and gas chromatography mass spectrometry for determination of polycyclic aromatic hydrocarbons in smoked food samples
    Wang, GD
    Lee, AS
    Lewis, M
    Kamath, B
    Archer, RK
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1999, 47 (03) : 1062 - 1066
  • [40] Simultaneous determination of 76 micropollutants in water samples by headspace solid phase microextraction and gas chromatography-mass spectrometry
    Martinez, C.
    Ramirez, N.
    Gomez, V.
    Pocurull, E.
    Borrull, F.
    TALANTA, 2013, 116 : 937 - 945