Techniques and applications of skeletal muscle diffusion tensor imaging: A review

被引:162
作者
Oudeman, Jos [2 ]
Nederveen, Aart J. [2 ]
Strijkers, Gustav J. [3 ]
Maas, Mario [2 ]
Luijten, Peter R. [1 ]
Froeling, Martijn [1 ,2 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiol, Heidelberglaan 100, NL-3584 CX Utrecht, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Dept Radiol, Meibergdreef 9, NL-1105 AZ Amsterdam, Netherlands
[3] Univ Amsterdam, Acad Med Ctr, Biomed Engn & Phys, Meibergdreef 9, NL-1105 AZ Amsterdam, Netherlands
关键词
diffusion tensor imaging; skeletal muscle; applications; PARAMETRIC MRI CHARACTERIZATION; HUMAN THIGH MUSCLES; IN-VIVO; FIBER ARCHITECTURE; WATER DIFFUSION; HUMAN CALF; FRACTIONAL ANISOTROPY; 3.0; T; QUANTITATIVE ASSESSMENT; MAGNETIZATION-TRANSFER;
D O I
10.1002/jmri.25016
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Diffusion tensor imaging (DTI) is increasingly applied to study skeletal muscle physiology, anatomy, and pathology. The reason for this growing interest is that DTI offers unique, noninvasive, and potentially diagnostically relevant imaging readouts of skeletal muscle structure that are difficult or impossible to obtain otherwise. DTI has been shown to be feasible within most skeletal muscles. DTI parameters are highly sensitive to patient-specific properties such as age, body mass index (BMI), and gender, but also to more transient factors such as exercise, rest, pressure, temperature, and relative joint position. However, when designing a DTI study one should not only be aware of sensitivity to the above-mentioned factors but also the fact that the DTI parameters are dependent on several acquisition parameters such as echo time, b-value, and diffusion mixing time. The purpose of this review is to provide an overview of DTI studies covering the technical, demographic, and clinical aspects of DTI in skeletal muscles. First we will focus on the critical aspects of the acquisition protocol. Second, we will cover the reported normal variance in skeletal muscle diffusion parameters, and finally we provide an overview of clinical studies and reported parameter changes due to several (patho-)physiological conditions. J. Magn. Reson. Imaging 2016;43:773-788
引用
收藏
页码:773 / 788
页数:16
相关论文
共 133 条
[1]   Composite hindered and restricted model of diffusion (CHARMED) MR imaging of the human brain [J].
Assaf, Y ;
Basser, PJ .
NEUROIMAGE, 2005, 27 (01) :48-58
[2]  
Basser PJ, 1996, J MAGN RESON SER B, V111, P209, DOI [10.1006/jmrb.1996.0086, 10.1016/j.jmr.2011.09.022]
[3]   A 3D model of muscle reveals the causes of nonuniform strains in the biceps brachii [J].
Blemker, SS ;
Pinsky, PM ;
Delp, SL .
JOURNAL OF BIOMECHANICS, 2005, 38 (04) :657-665
[4]   Water diffusion features as indicators of muscle structure ex vivo [J].
Bonny, JM ;
Renou, JP .
MAGNETIC RESONANCE IMAGING, 2002, 20 (05) :395-400
[5]   Multi-parametric MRI characterization of inflammation in murine skeletal muscle [J].
Bryant, Nathan D. ;
Li, Ke ;
Does, Mark D. ;
Barnes, Stephanie ;
Gochberg, Daniel F. ;
Yankeelov, Thomas E. ;
Park, Jane H. ;
Damon, Bruce M. .
NMR IN BIOMEDICINE, 2014, 27 (06) :716-725
[6]   In vivo MR tractography of thigh muscles using diffusion imaging: initial results [J].
Budzik, J. F. ;
Le Thuc, V. ;
Demondion, X. ;
Morel, M. ;
Chechin, D. ;
Cotten, A. .
EUROPEAN RADIOLOGY, 2007, 17 (12) :3079-3085
[7]   Diffusion Tensor Imaging in Musculoskeletal Disorders [J].
Budzik, Jean-Francois ;
Balbi, Vincent ;
Verclytte, Sebastien ;
Pansini, Vittorio ;
Le Thuc, Vianney ;
Cotten, Anne .
RADIOGRAPHICS, 2014, 34 (03) :E56-E72
[8]   Validation of diffusion tensor MRI-based muscle fiber tracking [J].
Damon, BM ;
Ding, ZH ;
Anderson, AW ;
Freyer, AS ;
Gore, JC .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (01) :97-104
[9]   Effects of image noise in muscle diffusion tensor (DT)-MRI assessed using numerical simulations [J].
Damon, Bruce M. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (04) :934-944
[10]   Polynomial fitting of DT-MRI fiber tracts allows accurate estimation of muscle architectural parameters [J].
Damon, Bruce M. ;
Heemskerk, Anneriet M. ;
Ding, Zhaohua .
MAGNETIC RESONANCE IMAGING, 2012, 30 (05) :589-600