No Signal Intensity Increase in the Dentate Nucleus on Unenhanced T1-weighted MR Images after More than 20 Serial Injections of Macrocyclic Gadolinium-based Contrast Agents

被引:91
作者
Radbruch, Alexander [1 ,3 ,4 ,5 ,6 ]
Haase, Robert [1 ,3 ,4 ,5 ]
Kieslich, Pascal J. [7 ]
Weberling, Lukas D. [1 ,3 ,4 ,5 ]
Kickingereder, Philipp [1 ]
Wick, Wolfgang [2 ]
Schlemmer, Heinz-Peter [3 ]
Bendszus, Martin [1 ]
机构
[1] Heidelberg Univ, Med Ctr, Dept Neuroradiol, Neuenheimer Feld 400, D-69120 Heidelberg, Germany
[2] Heidelberg Univ, Med Ctr, Neurol Clin, Neuenheimer Feld 400, D-69120 Heidelberg, Germany
[3] German Canc Res Ctr, Dept Radiol, Heidelberg, Germany
[4] German Canc Consortium DKTK, Heidelberg, Germany
[5] German Canc Consortium DKTK, Heidelberg, Germany
[6] Univ Duisburg Essen, Univ Hosp Essen, Dept Diagnost & Intervent Radiol & Neuroradiol, Essen, Germany
[7] Univ Mannheim, Dept Psychol, Mannheim, Germany
关键词
NORMAL RENAL-FUNCTION; GLOBUS-PALLIDUS; T1; HYPERINTENSITY; HEALTHY RATS; KNOW ENOUGH; BRAIN; DEPOSITION; ADMINISTRATIONS; DIMEGLUMINE; GADODIAMIDE;
D O I
10.1148/radiol.2016162241
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine the effect of more than 20 serial injections of macrocyclic gadolinium-based contrast agents (GBCAs) on the signal intensity (SI) of the dentate nucleus (DN) on unenhanced T1-weighted magnetic resonance (MR) images. Materials and Methods: In this retrospective, institutional review board-approved study, 33 patients who underwent at least 20 consecutive MR imaging examinations (plus an additional MR imaging for reference) with the exclusive use of macrocyclic GBCAs gadoterate meglumine and gadobutrol were analyzed. SI ratio differences were calculated for DN-to-pons and DN-to- middle cerebellar peduncle (MCP) ratios by subtracting the SI ratio at the first MR imaging examination from the SI ratio at the last MR imaging examination. One-sample t tests were used to examine if the SI ratio differences differed from 0, and Bayes factors were calculated to quantify the strength of evidence for each test. Results: Patients underwent a mean of 23.03 +/- (standard deviation) 4.20 GBCA administrations (mean accumulated dose, 491.21 mL +/- 87.04 of a 0.5 M GBCA solution) with an average of 12.09 weeks +/- 2.16 between every administration. Both ratio differences did not differ significantly from 0 (DN-to-pons ratio: -0.0032 +/- 0.0154, P = .248; DN-to-MCP ratio: -0.0011 +/- 0.0093, P = .521), and one-sided Bayes factors provided substantial to strong evidence against an SI ratio increase (Bayes factor for DN-to-pons ratio = 0.09 and that for DN-to-MCP ratio = 0.12). Conclusion: The study indicates that 20 or more serial injections of macrocyclic GBCAs administered with on average 3 months between each injection are not associated with an SI increase in the DN. (C) RSNA, 2016
引用
收藏
页码:699 / 707
页数:9
相关论文
共 38 条
[1]   Hyperintense Dentate Nuclei on T1-Weighted MRI: Relation to Repeat Gadolinium Administration [J].
Adin, M. E. ;
Kleinberg, L. ;
Vaidya, D. ;
Zan, E. ;
Mirbagheri, S. ;
Yousem, D. M. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (10) :1859-1865
[2]  
[Anonymous], RADIOLOGY
[3]   Effect of Renal Function on Gadolinium-Related Signal Increases on Unenhanced T1-Weighted Brain Magnetic Resonance Imaging [J].
Cao, Yan ;
Zhang, Yang ;
Shih, George ;
Zhang, Yan ;
Bohmart, Andrew ;
Hecht, Elizabeth M. ;
Prince, Martin R. .
INVESTIGATIVE RADIOLOGY, 2016, 51 (11) :677-682
[4]   Signal Change in the Dentate Nucleus on T1-Weighted MR Images After Multiple Administrations of Gadopentetate Dimeglumine Versus Gadobutrol [J].
Cao, Yan ;
Huang, Daisy Q. ;
Shih, George ;
Prince, Martin R. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 206 (02) :414-419
[5]   Progressive Increase of T1 Signal Intensity of the Dentate Nucleus on Unenhanced Magnetic Resonance Images Is Associated With Cumulative Doses of Intravenously Administered Gadodiamide in Patients With Normal Renal Function, Suggesting Dechelation [J].
Errante, Yuri ;
Cirimele, Vincenzo ;
Mallio, Carlo Augusto ;
Di Lazzaro, Vincenzo ;
Zobel, Bruno Beomonte ;
Quattrocchi, Carlo Cosimo .
INVESTIGATIVE RADIOLOGY, 2014, 49 (10) :685-690
[6]   Stability of Gadolinium-Based Magnetic Resonance Imaging Contrast Agents in Human Serum at 37°C [J].
Frenzel, Thomas ;
Lengsfeld, Philipp ;
Schirmer, Heiko ;
Huetter, Joachim ;
Weinmann, Hanns-Joachim .
INVESTIGATIVE RADIOLOGY, 2008, 43 (12) :817-828
[7]   Increased signal intensities in the dentate nucleus and globus pallidus on unenhanced T1-weighted images: evidence in children undergoing multiple gadolinium MRI exams [J].
Hu, Houchun H. ;
Pokorney, Amber ;
Towbin, Richard B. ;
Miller, Jeffrey H. .
PEDIATRIC RADIOLOGY, 2016, 46 (11) :1590-1598
[8]  
Huang D, 2015, P 23 M INT SOC MAGN, P3229
[9]  
Jeffreys H, 1998, THEORY PROBABILITY
[10]   Signal Increase on Unenhanced T1-Weighted Images in the Rat Brain After Repeated, Extended Doses of Gadolinium-Based Contrast Agents Comparison of Linear and Macrocyclic Agents [J].
Jost, Gregor ;
Lenhard, Diana Constanze ;
Sieber, Martin Andrew ;
Lohrke, Jessica ;
Frenzel, Thomas ;
Pietsch, Hubertus .
INVESTIGATIVE RADIOLOGY, 2016, 51 (02) :83-89