Signal enhancement in a protein chip array using a 3-D nanosurface

被引:24
|
作者
Kim, So Yeon [1 ]
Yu, Jaeeun [2 ]
Son, Sang Jun [1 ]
Min, Junhong [1 ]
机构
[1] Kyungwon Univ, Dept BioNano Technol, Gyeonggi Do 461701, South Korea
[2] Seoul Natl Univ, Dept Chem, Seoul 151747, South Korea
关键词
3-D nanosurface; Silica nanotube; PDMS; Protein aggregation; AFM; Surface roughness; GENE-EXPRESSION; MICROARRAYS; NANOTUBES; SUPPORT;
D O I
10.1016/j.ultramic.2010.02.028
中图分类号
TH742 [显微镜];
学科分类号
摘要
A silica based 3-D nanosurface was developed to enhance the signal intensity of a protein chip by increasing the surface density and reducing the aggregation of captured proteins immobilized on the nanosurface. The 3-D nanosurface was composed of silica nanopillar bundles formed from a nanoporous alumina template using the sol-gel method. The signal intensity of a protein spot increased exponentially when the capture probe was immobilized on a nanosurface with higher roughness and the amount of protein immobilized on the surface was proportional to the roughness of the nanosurface. To further investigate this nanosurface effect, changes in the nanosurface roughness before and after protein immobilization were investigated by AFM. The surface roughness was shown to increase after protein immobilization when the nanosurface initially had a relatively low surface roughness (Rq: 30-40 nm); however, the surface roughness decreased after protein immobilization when it initially had a high roughness (Rq: 60-130 nm). These results imply that a high nanosurface roughness decreases the overall aggregation of proteins on the surface. These findings were also confirmed by comparing the level of protein aggregation on nanosurfaces with high roughness and low roughness using AFM. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:659 / 665
页数:7
相关论文
共 50 条
  • [1] Signal enhancement of protein chips using 3D-materials for immobilization
    Preininger, C
    Sauer, U
    Obersriebnig, S
    Trombitas, M
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2005, 85 (9-11) : 645 - 654
  • [2] Full-Chip Signal Integrity Analysis and Optimization of 3-D ICs
    Song, Taigon
    Liu, Chang
    Peng, Yarui
    Lim, Sung Kyu
    IEEE TRANSACTIONS ON VERY LARGE SCALE INTEGRATION (VLSI) SYSTEMS, 2016, 24 (05) : 1636 - 1648
  • [3] 3-D DOCUMENTATION ARRAY
    HILL, MF
    COMMUNICATIONS OF THE ACM, 1963, 6 (05) : 193 - &
  • [4] MAGNETIC INTERPRETATION USING THE 3-D ANALYTIC SIGNAL
    ROEST, WR
    VERHOEF, J
    PILKINGTON, M
    GEOPHYSICS, 1992, 57 (01) : 116 - 125
  • [5] A 3-D dielectrophoretic filter chip
    Iliescu, Ciprian
    Xu, Guolin
    Loe, Felicia Celeste
    Ong, Poh Lam
    Tay, Francis E. H.
    ELECTROPHORESIS, 2007, 28 (07) : 1107 - 1114
  • [6] THE RISE OF THE MONOLITHIC 3-D CHIP
    Courtland, Rachel
    IEEE SPECTRUM, 2014, 51 (03) : 18 - 19
  • [7] BIOL 233-Preparation of 3-D aerogel protein array
    Wu, Jui-Chuang
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2007, 234
  • [8] 3-D Ultrasound Imaging Using Helicoid Array Transducers
    Kim, Young-Joong
    Wolf, Patrick D.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (03) : 697 - 706
  • [9] 3-D displays and signal processing - An answer to 3-D ills?
    Konrad, Janusz
    Halle, Michael
    IEEE SIGNAL PROCESSING MAGAZINE, 2007, 24 (06) : 97 - 111
  • [10] Medical volume enhancement using 3-d brushlet transform
    Selver, M. Alper
    Dicle, Oguz
    JOURNAL OF THE FACULTY OF ENGINEERING AND ARCHITECTURE OF GAZI UNIVERSITY, 2018, 33 (04): : 1215 - 1230