Solid phase extraction of copper(II) ions using C18-silica disks modified by oxime ligands

被引:27
作者
Dindar, M. Hami [1 ]
Fathi, S. A. M. [1 ]
Yaftian, M. R. [1 ]
Noushiranzadeh, N. [1 ]
机构
[1] Zanjan Univ, Phase Equilibria Res Lab, Dept Chem, Zanjan, Iran
关键词
Copper(II) ions; Solid phase extraction; Octadecyl silica membrane disk; Oxime; ATOMIC-ABSORPTION-SPECTROMETRY; SILICA MEMBRANE DISKS; WATER SAMPLES; BASE; LEAD;
D O I
10.1016/j.jhazmat.2010.02.092
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
5-Tert-butyl-2-hydroxy-benzaldehyde oxime (L-1) and 3,5-di-tert-butyl-2-hydroxy-benzaldehydeoxime (L-2) are synthesized and characterized by conventional spectroscopic methods. These ligands are used as modifier of octadecyl silica membrane disks for separation and pre-concentration of trace amounts of copper(II) ions, followed by sulfuric or nitric acid elution and flame atomic absorption spectrometric (FAAS) determination. The effect of parameters influencing the extraction efficiency i.e. pH of sample solutions, amount of the oxime, type and volume of eluent, sample solution and eluent flow rates were evaluated. Under optimum experimental conditions, the maximum capacity of the membrane disks modified by 6 mg of L-1 or 4 mg of L-2 was found to be 284.7 (+/- 2.8) mu g of copper and 382.5 (+/- 3.1) mu g of copper, respectively. The detection limits of the presented methods are 0.29 ng ml(-1) for L-1 and 0.25 ng ml(-1) for L-2. The enrichment factors are greater than 400 for both cases. These methods were successfully applied to the extraction, recovery and detection of copper in different water samples. (c) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:289 / 294
页数:6
相关论文
共 11 条
[1]   Determination of iron and copper in peanuts by flame atomic absorption spectrometry using acid digestion [J].
Anzano, JM ;
Gónzalez, P .
MICROCHEMICAL JOURNAL, 2000, 64 (02) :141-145
[2]   Determination of fluorescent whitening agents in environmental waters by solid-phase extraction and ion pair liquid chromatography-tandem mass spectrometry [J].
Chen, HC ;
Wang, SP ;
Ding, WH .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1102 (1-2) :135-142
[3]   Ultrasound-assisted treatment of palm oil samples for the determination of copper and lead by stripping chronopotentiometry [J].
Cypriano, Joao Carlos ;
Costa Matos, Maria Auxiliadora ;
Matos, Renato Camargo .
MICROCHEMICAL JOURNAL, 2008, 90 (01) :26-30
[4]  
Dalman Ö, 2003, TURK J CHEM, V27, P649
[5]   Cloud point extraction and flame atomic absorption spectrometry determination of trace amounts of copper(II) ions in water samples [J].
Fathi, S. A. M. ;
Yaftian, M. R. .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2009, 334 (02) :167-170
[6]   Enrichment of trace amounts of copper(II) ions in water samples using octadecyl silica disks modified by a Schiff base ionophore prior to flame atomic absorption spectrometric determination [J].
Fathi, S. A. M. ;
Yaftian, M. R. .
JOURNAL OF HAZARDOUS MATERIALS, 2009, 164 (01) :133-137
[7]   Spectrophotometric determination of trace copper in water samples with thiornichlersketone [J].
Fu, Dayou ;
Yuan, Dong .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2007, 66 (02) :434-437
[8]   Direct determination of copper, lead and cadmium in aniseed spirits by electrothermal atomic absorption spectrometry [J].
Jurado, J. M. ;
Martin, M. J. ;
Pablos, F. ;
Moreda-Pineiro, A. ;
Bermejo-Barrera, P. .
FOOD CHEMISTRY, 2007, 101 (03) :1296-1304
[9]   Solid phase extraction of ultra trace copper(II) using octadecyl silica membrane disks modified by a naphthol-derivative Schiff's base [J].
Shamsipur, M ;
Ghiasvand, AR ;
Sharghi, H ;
Naeimi, H .
ANALYTICA CHIMICA ACTA, 2000, 408 (1-2) :271-277
[10]   Cloud point extraction and flame atomic absorption spectrometry combination for copper(II) ion in environmental and biological samples [J].
Shokrollahi, Ardeshir ;
Ghaedi, Mehrorang ;
Hossaini, Omid ;
Khanjari, Narges ;
Soylak, Mustafa .
JOURNAL OF HAZARDOUS MATERIALS, 2008, 160 (2-3) :435-440