Modeling the behavior of fiber reinforced polymer-confined concrete columns exposed to fire

被引:77
|
作者
Bisby, LA [1 ]
Green, MF
Kodur, VKR
机构
[1] Queens Univ, Dept Civil Engn, Kingston, ON K7L 3N6, Canada
[2] Natl Res Council Canada, Inst Rech Construct, Fire Risk Management Program, Ottawa, ON K1A 0R6, Canada
关键词
concrete columns; fiber reinforced polymers; rehabilitation; confinement; fire resistance; fire protection; heat transfer; numerical analysis;
D O I
10.1061/(ASCE)1090-0268(2005)9:1(15)
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Very little information is available oil the behavior of fiber reinforced polymer (FRP) materials and FRP-strengthened concrete members in fire, and this is a primary factor hindering the widespread implementation of FRP strengthening technologies in the construction industry. This paper presents a numerical model for evaluating the fire behavior of conventionally reinforced circular concrete columns, FRP-wrapped reinforced concrete columns, and insulated FRP-wrapped reinforced concrete columns. The model is validated against data available in the literature from full-scale fire endurance tests oil conventionally reinforced concrete columns. and preliminary predictions of the model are presented and discussed. It is demonstrated that the model agrees reasonably well with experimental data obtained from tests on circular reinforced concrete columns, that it is unlikely that the structural effectiveness of FRP materials can be maintained during fire, and that the fire behavior of FRP-wrapped columns can be dramatically improved by providing Supplemental insulation for the FRP.