Tibiofemoral dynamic stressed gap laxities correlate with compartment load measurements in robotic arm-assisted total knee arthroplasty

被引:8
|
作者
Allom, R. J. [1 ]
Wood, J. A. [1 ]
Chen, D. B. [1 ]
MacDessi, S. J. [1 ]
机构
[1] St George Private Hosp, Sydney Knee Specialists, Sydney, NSW, Australia
来源
BONE & JOINT OPEN | 2021年 / 2卷 / 11期
关键词
Restricted kinematic alignment; Functional positioning; Virtual gap balancing; Load sensor; Total knee arthroplasty; Robot-assisted TKA; SOFT-TISSUE BALANCE; STRUCTURAL-PROPERTIES; COLLATERAL LIGAMENTS; JOINT; ALIGNMENT; FLEXION; DIFFERENCE; EXTENSION; ANTERIOR; OUTCOMES;
D O I
10.1302/2633-1462.211.BJO-2021-0066.R1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aims It is unknown whether gap laxities measured in robotic arm-assisted total knee arthroplasty (TKA) correlate to load sensor measurements. The aim of this study was to determine whether symmetry of the maximum medial and lateral gaps in extension and flexion was predictive of knee balance in extension and flexion respectively using different maximum thresholds of intercompartmental load difference (ICLD) to define balance. Methods A prospective cohort study of 165 patients undergoing functionally-aligned TKA was performed (176 TKAs). With trial components in situ, medial and lateral extension and flexion gaps were measured using robotic navigation while applying valgus and varus forces. The ICLD between medial and lateral compartments was measured in extension and flexion with the load sensor. The null hypothesis was that stressed gap symmetry would not correlate directly with sensor-defined soft tissue balance. Results In TKAs with a stressed medial-lateral gap difference of <= 1 mm, 147 (89%) had an ICLD of <= 15 lb in extension, and 112 (84%) had an ICLD of <= 15 lb in flexion; 157 (95%) had an ICLD <= 30 lb in extension, and 126 (94%) had an IUD <= 30 lb in flexion; and 165 (100%) had an ICLD <= 60 lb in extension, and 133 (99%) had an ICLD <= 60 lb in flexion. With a 0 mm difference between the medial and lateral stressed gaps, 103 (91%) of TKA had an ICLD <= 15 lb in extension, decreasing to 155 (88%) when the difference between the medial and lateral stressed extension gaps increased to +/- 3 mm. In flexion, 47 (77%) had an ICLD <= 15 lb with a medial-lateral gap difference of 0 mm, increasing to 147 (84%) at +/- 3 mm. Conclusion This study found a strong relationship between intercompartmental loads and gap symmetry in extension and flexion measured with prostheses in situ. The results suggest that ICLD and medial-lateral gap difference provide similar assessment of soft-tissue balance in robotic arm-assisted TKA.
引用
收藏
页码:974 / 980
页数:7
相关论文
共 50 条
  • [41] Identifying subgroups of patients that may benefit from robotic arm-assisted total knee arthroplasty: Secondary analysis of data from a randomised controlled trial
    Clement, Nick D.
    Galloway, Steven
    Baron, Jenny
    Smith, Karen
    Weir, David J.
    Deehan, David J.
    KNEE, 2024, 48 : 94 - 104
  • [42] Robotic-arm Assisted Total Knee Arthroplasty: the Relationship between Bone Resection, Gap Balancing and Resultant Implant Alignment
    Clement, Nicholas D.
    Weir, David J.
    Deehan, David J.
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2023, 11 (04): : 277 - 283
  • [43] Robotic-Arm Assisted Total Knee Arthroplasty: Cost Savings Demonstrated at One Year
    Ong, Kevin L.
    Coppolecchia, Andrea
    Chen, Zhongming
    Watson, Heather N.
    Jacofsky, David
    Mont, Michael A.
    CLINICOECONOMICS AND OUTCOMES RESEARCH, 2022, 14 : 309 - 318
  • [44] Two- and three-dimensional measurements following robotic-assisted total knee arthroplasty
    Hasegawa, Masahiro
    Tone, Shine
    Naito, Yohei
    Sudo, Akihiro
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2022, 18 (06):
  • [45] Robotic arm-assisted unicompartmental knee arthroplasty: high survivorship and good patient-related outcomes at a minimum five years of follow-up
    Zambianchi, Francesco
    Daffara, Valerio
    Franceschi, Giorgio
    Banchelli, Federico
    Marcovigi, Andrea
    Catani, Fabio
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2021, 29 (10) : 3316 - 3322
  • [46] Robotic-Arm Assisted Total Knee Arthroplasty Demonstrated Greater Accuracy and Precision to Plan Compared with Manual Techniques
    Hampp, Emily L.
    Chughtai, Morad
    Scholl, Laura Y.
    Sodhi, Nipun
    Bhowmik-Stoker, Manoshi
    Jacofsky, David J.
    Mont, Michael A.
    JOURNAL OF KNEE SURGERY, 2019, 32 (03) : 239 - 250
  • [47] Robotic arm-assisted posterior-stabilised total knee arthroplasty reduces the amount of tibial bone resection thickness without increasing the rate of postoperative flexion contracture in varus knees in the short term: Comparison with image-free navigated total knee arthroplasty
    Ishida, Kazunari
    Shibanuma, Nao
    Hayashi, Shinya
    Kurosaka, Masahiro
    Kuroda, Ryosuke
    Matsumoto, Tomoyuki
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2022, 18 (03):
  • [48] The Learning Curve of Reaching the Planned Limb Alignment in Robotic-Arm-Assisted Total Knee Arthroplasty
    Pannu, Tejbir S.
    Villa, Jesus M.
    Schultz, Isaac
    Barsoum, Wael K.
    Higuera, Carlos A.
    Patel, Preetesh D.
    JOURNAL OF KNEE SURGERY, 2023, 36 (06) : 682 - 688
  • [49] High in-vivo accuracy of a novel robotic-arm-assisted system for total knee arthroplasty
    Zaidi, Faseeh
    Goplen, Craig M.
    Fitz-Gerald, Connor
    Bolam, Scott M.
    Hanlon, Michael
    Munro, Jacob T.
    Monk, Andrew P.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2025, 33 (01) : 229 - 238
  • [50] Can Robotic Arm-assisted Total Knee Arthroplasty Remain Cost-effective in Volume-based Procurement System in China? A Markov Model-based Study
    Zhang, Zhuo
    Luo, Yang
    Zhang, Jing
    Zhang, Chong
    Wang, Xin
    Chen, Jiying
    Chai, Wei
    ORTHOPAEDIC SURGERY, 2024, 16 (06) : 1434 - 1444