Accuracy of heparin-induced platelet aggregation test for the diagnosis of heparin-induced thrombocytopenia

被引:23
作者
Brodard, Justine [1 ,2 ]
Alberio, Lorenzo [3 ,4 ,5 ]
Angelillo-Scherrer, Anne [1 ,2 ,6 ]
Nagler, Michael [1 ,2 ,7 ]
机构
[1] Bern Univ Hosp, Inselspital, Dept Hematol, Bern, Switzerland
[2] Bern Univ Hosp, Inselspital, Cent Hematol Lab, Bern, Switzerland
[3] Univ Lausanne, Univ Lausanne Hosp, CHUV, Div Hematol, Lausanne, Switzerland
[4] Univ Lausanne, Univ Lausanne Hosp, CHUV, Cent Hematol Lab, Lausanne, Switzerland
[5] Univ Lausanne, Fac Biol & Med, Lausanne, Switzerland
[6] Univ Bern, Dept BioMed Res, Bern, Switzerland
[7] Univ Bern, Univ Inst Clin Chem, Inselspital, Univ Hosp Bern, Freiburgerstr, CH-3010 Bern, Switzerland
基金
瑞士国家科学基金会;
关键词
Heparin-induced thrombocytopenia; Heparin/adverse effects; Thrombocytopenia/chemically induced; Thrombocytopenia/diagnosis; Immunoassay/methods; LABORATORY DIAGNOSIS; IMMUNOASSAYS; CONFIRMATION;
D O I
10.1016/j.thromres.2019.11.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Whereas the utility of washed platelet assays such as the heparin-induced platelet activation test (HIPA) for the diagnosis of heparin-induced thrombocytopenia (HIT) is regarded as high, the performance of simpler assays such as the heparin-induced platelet aggregation test (PAT) is still elusive. Using well-characterized samples of a large cohort study, we aimed to assess the diagnostic accuracy of PAT for the diagnosis of HIT. Material and methods: One-hundred twenty-two immunoassay-positive serum samples of a previous, prospective single-center cohort study including consecutive patients with suspected HIT (n = 1291) were used. HIPA was determined as reference gold standard; samples were previously analyzed using PAT as well as polyspecific platelet factor 4/heparin enzyme-linked immunosorbent assay (ELISA). 4Ts score was calculated using the patient documentation. Diagnosis of HIT was defined as a positive HIPA, which is a positive reaction in 2 out of 4 donor platelets within 30 min. Results: HIT was diagnosed in 39 out of 122 patients corresponding to a prevalence of 32%. Median optical density (ELISA) was 2.8 (inter-quartile range 2.3, 3.0) in patients with HIT and 0.7 (0.5, 1.3) in patients without HIT. PAT was positive in 27 out of 39 HIT patients and it was negative in 83 out of 83 HIT-negative patients. Thus, the sensitivity of PAT for the diagnosis of HIT was 69% (95% confidence interval 52%, 83%) and the specificity 100% (96%, 100%). Conclusions: Our results demonstrate that PAT is a valuable test to confirm HIT but cannot be applied to rule-out HIT in clinical practice.
引用
收藏
页码:27 / 30
页数:4
相关论文
共 13 条
[1]   Current insights into the laboratory diagnosis of HIT [J].
Bakchoul, T. ;
Zoellner, H. ;
Greinacher, A. .
INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2014, 36 (03) :296-305
[2]  
CHONG BH, 1993, THROMB HAEMOSTASIS, V69, P344
[3]   Predictive value of the 4Ts scoring system for heparin-induced thrombocytopenia: a systematic review and meta-analysis [J].
Cuker, Adam ;
Gimotty, Phyllis A. ;
Crowther, Mark A. ;
Warkentin, Theodore E. .
BLOOD, 2012, 120 (20) :4160-4167
[4]   Heparin-induced thrombocytopenia (HIT) in 2011: An epidemic of overdiagnosis [J].
Cuker, Adam .
THROMBOSIS AND HAEMOSTASIS, 2011, 106 (06) :993-994
[5]   HEPARIN - INDUCED THROMBOCYTOPENIA - LABORATORY INVESTIGATION AND CONFIRMATION OF DIAGNOSIS [J].
FAVALORO, EJ ;
BERNALHOYOS, E ;
EXNER, T ;
KOUTTS, J .
PATHOLOGY, 1992, 24 (03) :177-183
[6]   LABORATORY DIAGNOSIS OF HEPARIN-ASSOCIATED THROMBOCYTOPENIA AND COMPARISON OF PLATELET-AGGREGATION TEST, HEPARIN-INDUCED PLATELET ACTIVATION TEST, AND PLATELET FACTOR-4 HEPARIN ENZYME-LINKED-IMMUNOSORBENT-ASSAY [J].
GREINACHER, A ;
AMIRAL, J ;
DUMMEL, V ;
VISSAC, A ;
KIEFEL, V ;
MUELLERECKHARDT, C .
TRANSFUSION, 1994, 34 (05) :381-385
[7]   Functional Assays in the Diagnosis of Heparin-Induced Thrombocytopenia: A Review [J].
Minet, Valentine ;
Dogne, Jean-Michel ;
Mullier, Francois .
MOLECULES, 2017, 22 (04)
[8]   Clinical and laboratory tests for the diagnosis of heparin-induced thrombocytopenia [J].
Nagler, Michael ;
Bakchoul, Tamam .
THROMBOSIS AND HAEMOSTASIS, 2016, 116 (05) :823-834
[9]   Diagnostic value of immunoassays for heparin-induced thrombocytopenia: a systematic review and meta-analysis [J].
Nagler, Michael ;
Bachmann, Lucas M. ;
ten Cate, Hugo ;
ten Cate-Hoek, Arina .
BLOOD, 2016, 127 (05) :546-557
[10]   Rapid exclusion or confirmation of heparin-induced thrombocytopenia: a single-center experience with 1,291 patients [J].
Nellen, Vanessa ;
Sulzer, Irmela ;
Barizzi, Gabriela ;
Laemmle, Bernhard ;
Alberio, Lorenzo .
HAEMATOLOGICA-THE HEMATOLOGY JOURNAL, 2012, 97 (01) :89-97